Ovo je obavezno polje.
Invalid
Broj dijela
Pogreška pri provjeri valjanosti!

Modular Compact Rheometer:
MCR 102e/302e/502e

Model:
  • Your entry ticket into the world of QC testing and rheological product development, upgradeable with sample-adaptive controllers
  • EC motor technology based on 25 years of expertise and market leadership with a torque range from 2 nNm to 200 mNm
  • Normal force measurements up to 50 N
Samo internetska cijena | isklj.uklj. 0PDV
Cijena
na zahtjev
Informacije o kupnji
Kupi Anton Paar instrumente putem interneta
Broj dijela:
Provjerite dostupnost u internetskoj trgovini Zatražite ponudu Kupite ovaj proizvod putem interneta
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

The new MCR Evolution series is the result of consistent thinking and rethinking, of continuous development based on decades of experience and the feedback of more than 10,000 satisfied customers. The combination of innovative and thousandfold field-proven technology with the modular design represents the benchmark in its class. With 200+ accessories the MCR Evolution rheometer series gives you endless possibilities for rheological investigations and material characterization. Experience sophisticated rheological research and advanced QC testing like never before. 

Glavne značajke

The best now better: the new MCR Evolution series

For more than 25 years we have continuously extended our portfolio in close collaboration with our most important innovation driver, YOU, our highly valued customers and rheometer users. We are now proud to present the new MCR Evolution series: rheometers that push your work one step ahead.

The benefits of the new MCR Evolution series

The benefits of the new MCR Evolution series

  • The fastest one-hand coupling and decoupling of measuring geometries in just one second – even at extreme temperatures (-160 °C to 1000 °C): Novel quick-connect mechanism
  • Precisely measure even low-viscosity samples with our entry-budget model: Higher sensitivity (from 7.5 nNm to 2 nNm)
  • Stable results even for long-term measurements with low torque: Improved thermal management within the EC motor starting from MCR 302e
  • More space for sample handling and exchange of accessories: Extended working height starting from MCR 302e
  • The only device on the market with a trimming mirror for a 360° view of the sample with no blind spots, which avoids sample preparation errors and leads to highly reproducible results.
  • Detection of any sample behavior change even at the shortest time scales: Reproducible duration of each measuring point down to 1 ms
  • Full pharma compliance: The best pharma package for the RheoCompass software (21 CFR Part 11, full data integrity according to ALCOA+)
Takes work off your hands: Unique motor and sample-adaptive controller technology

Takes work off your hands: Unique motor and sample-adaptive controller technology

The MCR Evo series builds on 25 years of research, development, and constant improvement. This results in technology which pushes the boundaries of rheometry. The combination of the EC motor (Permanent Magnet Synchronous Motor) using a high-precision air bearing with active thermal management, integrated normal force sensor, and a high-resolution optical encoder, for example, allows rheological measurements at the lowest torques ever. The unique sample-adaptive controllers for measurement in rotation (TruRate™) and oscillation (TruStrain™) work for 99 % of all samples and measurements “out of the box” with the perfect combination of speed and accuracy – save time and nerves and even get better data at the same time!

Excellence in every component and every work step

Excellence in every component and every work step

After decades in the field, Anton Paar understands and anticipates what is required for outstanding rheological analysis. With this knowledge in mind, we designed every component and created every handling step to be part of a smooth and intelligent whole:

  • The patented Toolmaster™ technology automatically recognizes measuring systems
  • One-hand exchange of measuring systems due to the QuickConnect coupling
  • T-Ready™ detects sample temperature equilibration in real-time
  • The TruGap™ feature detects the real measuring gap
  • The trimming mirror gives you a 360° view of the sample and thus supports high measurement repeatability. And many more
Choose from more than 100 test templates, set report filters, and use remote control

Choose from more than 100 test templates, set report filters, and use remote control

The intuitive RheoCompass software offers predefined as well as customized test templates and analysis definitions. Furthermore, it is possible to export your rheological data and generate reports. Data can easily be filtered by e.g. year, batch number, or operator, and displayed within seconds. Due to the Ethernet connection, the rheometer can be remote-controlled from anywhere via the company network. Gap setting, adjustments, and tests can also be started directly from the MCR rheometer, minimizing annoying switches between the computer and the device, e.g. during sample preparation.

Unlimited possibilities: add one of more than 200 accessories

Unlimited possibilities: add one of more than 200 accessories

Whatever your rheological applications are and will be in the future – Anton Paar rheometers are quickly and easily adapted to meet your needs. Their flexibility makes them the most cited instruments in scientific publications on rheological investigations. An extensive range of application-specific accessories is available to extend the rheometer’s capabilities, including DMA measurements, extensional rheology, rheo-optics (e.g. microscopy and Raman spectroscopy), magneto- and electrorheology, dielectric spectroscopy, interfacial rheology, UV curing, pressure- and humidity-dependent rheology, tribology, and many more. A wide range of temperature accessories allow you to apply and control temperatures from -160 °C to 1000 °C.

Your partner for special applications and customized solutions

Your partner for special applications and customized solutions

With the special model MCR 502e Power you have the highest available torque of 300 mNm and highest available normal force of 70 N at your fingertips. This means you can perform fatigue- and heating-controlled stress tests on asphalt mixtures, for example.

Based on decades of experience in rheometry and rheology, Anton Paar can make nearly everything possible. We develop and supply customized products for all kinds of specific applications. With our in-house production in Austria and a dedicated R&D team just next door, we develop and supply customized products for all kinds of specific applications. Don’t hesitate to contact us in order to discuss your requirements and to find a customized solution for your measurement task.

Tehničke specifikacije

Technical Data Unit MCR 102e MCR 302e MCR 502e Power
Bearing design - Air, fine-pored carbon
Motor design - Electronically Commutated (EC) - Permanent Magnet Synchronous Motor
Displacement transducer design - High-resolution optical encoder
Normal force measurement design
(US Pat. 6167752, 1996)
- 360 ° capacitive sensor, non-contacting, fully integrated in bearing
Active thermal management of bearing and normal force sensor - No Yes Yes
Working modes - Combined Motor Transducer (CMT)
Minimum torque (rotation) nNm 5 1 100
Minimum torque (oscillation) nNm 5 [1] 0.5 50
Maximum torque mNm 200 230 300
Minimum angular deflection (set value) µrad 0.5 0.05 0.05
Maximum angular deflection (set value) µrad
Minimum angular velocity [2] rad/s 0 0 0
Maximum angular velocity
Maximum speed
rad/s
1/min
314
3000
314
3000
220
2100
Minimum angular frequency [3] rad/s 10 -7 10 -7 10 -7
Maximum angular frequency [4]
Maximum frequency
rad/s
Hz
628
100
628
100
628
100
Normal force range N -50 to 50 -50 to 50 -70 to 70
With Exposed Support Plate (WESP / Space) [5] - No Optional No
Without Support Plate (WSP) - No Optional No
Dimensions (W x H x D) mm 444 x 678 x 586 444 x 733 x 586 444 x 753 x 586
Weight kg 42 46 47
Additional Device Features
Device display with remote control of software
(decoupled from measuring sensor for mechanical and electromagnetic interference prevention)
- Yes Yes Yes
Direct strain/stress controller - Yes Yes Yes
TruRate™ / TruStrain™
(sample adaptive controller)
- Optional Yes Yes
Raw data (LAOS, waveform) - Optional Yes Yes
Normal force profiles (set and read) - Yes Yes Yes
Velocity profiles, tack, squeeze - Optional Yes Yes
Automatic gap control/setting (AGC/AGS) - Yes Yes Yes
Electronic trim lock for measuring geometry - Yes Yes Yes
Fully automatic temperature calibration - Yes Yes Yes
TruGap™
(permanent control of the real measuring gap)
(US Pat. 6499336, 2000)
- Optional Optional Optional
T-Ready™ [6]
(detection of sample temperature equilibrium time)
(US Pat. 8904852, 2011)
- Yes Yes Yes
Toolmaster™
(measuring geometries and accessories, storing of zero-gap)
(US Pat. 7275419, 2004)
- Yes Yes Yes
QuickConnect Coupling for measuring geometries
(one-hand operation, screwless)
- Yes Yes Yes
Trimming mirror
(360° blind sample spot prevention)
- Yes Yes Yes
Three-point support of device
(three robust feet for tool-free one hand alignment)
- Yes Yes Yes
Three-point support for mounting of measuring cells
(wobble prevention, no misalignment after changing of cells)
- Yes Yes Yes
Maximum temperature range °C -160 to +1000 -160 to +1000 -160 to +1000
Maximum pressure range bar up to 1000 up to 1000 up to 1000
Ready for DMA in torsion and tension - Yes Yes Yes
Ready for tribology - Yes Yes Yes
Ready for powder flow and shear rheology - Yes Yes Yes

[1] 2 nNm with activated TruStrain™ option
[2] In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode depending on measuring point duration and sampling rate.
[3] Theoretical value (duration per cycle = 2 years)
[4] Higher frequencies are possible using multi-wave functionality (942 rad/s (150 Hz) or even higher, depending on measuring system and sample)
[5] Enlarged working space underneath the support plate (flange) [6] Depending on used temperature device

Standardi

Otvori sve
Zatvori sve

ASTM

D4440
D4473
D5279

DIN

1342 1-3
3219
13343
51810 Dio 1.
51810 Dio 2.
53019-1
53019-2
54458

EN

3219
14770

ISO

3219
6721-1

Pharmacopoeia Europe (Ph. Eur.)

2.2.8 – Viskoznost
2.2.10 – Metoda s rotacijskim viskozimetrom
0132

U.S. Pharmacopoeia (USP)

912 – Metode s rotacijskim reometrom

Certificirana usluga servisa Anton Paar

Kvaliteta usluge Anton Paar u usluzi i podršci:
  • Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
  • Kvalificirana podrška na vašem lokalnom jeziku
  • Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
  • Trogodišnje jamstvo
Saznajte više

Dokumenti

Slični proizvodi

Consumables & Accessories

Consumables & Accessories

Accessories

Accessories

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

Samo internetska cijena | isklj.uklj. 0PDV

Spatula

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 98595

Drypoint Air Dryer with Air Filter Unit

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 10659

Activated Carbon Filter

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 10662

Optical accessory for MCR:
Rheometer-Infrared Spectrometer Setup

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • Accessory for structure analysis and rheo optics
  • Combines rheology with infrared spectroscopy
  • Investigates the chemical composition of a material

Više informacija

Measuring Cone CP40-1

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 2627

Konfiguracija reometar-Raman:
MCR WESP & Cora

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Kontrola temperature:
Sustavi Peltier s funkcijom TruGap™

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Accessory for MCR:
DMA Measuring Systems

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • For dynamic mechanical analysis (DMA) in bending, tension, torsion, and compression
  • Solid rectangular fixtures, three-point bending geometries, cantilevers, compression systems
  • Compatible with MCR 702e MultiDrive  

Više informacija

Univerzalni stezni mehanizam za ispitivanje rasteznih svojstava i Sentmanat ekstenzijski reometar:
UXF & SER

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Kontrola temperature za MCR:
Sustavi Peltier

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
The Magneto-Rheological Device (MRD) is used to investigate the influence of a magnetic field on magnetorheological fluids (MRF).

Dodatni pribor za MCR:
magnetoreološki uređaj

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Tlačne ćelije

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
The Electro-Rheological Device (ERD) with concentric cylinder measuring system (C-PTD 200/E) is used in combination with MCR rheometers to investigate the influence of an electric field on electrorheological fluids (ERF).

Elektroreologija

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Dodatni pribor za MCR:
Geometrije za reometar

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Dielektrična spektroskopija

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Accessory for MCR and RheolabQC:
Flexible Cup Holder

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • Accessory for “Extended Material Characterization"
  • Holds, for example: paint cans, yogurt cups, other containers
  • Can be combined with stirrers, concentric cylinder geometries, and a Pt100 temperature sensor

Više informacija

Uređaj za provjeru raspršenja svjetlosti pod malim kutom za MCR:
Rheo-SALS

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Measuring Plate PP15

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Broj dijela: 9899

UV sustav skrućivanja

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Dodatni pribor za MCR:
Sustav za međupovršinsku reologiju

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • Pribor za proširenu karakterizaciju materijala
  • Visokoprecizne studije svojstava tečenja međupovršinskih slojeva
  • Sveobuhvatna reološka istraživanja stabilnosti emulzija i pjena

Više informacija

Universal optical device with peltier or electrical temperature control

Reo-optika - reo-mikroskop

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Immobilization Cell: Characterize the immobilization kinetics of paper coatings

Imobilizacijska ćelija

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Mjerni sustav s kuglicom

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Kontrola temperature za MCR:
Cirkulatori tekućine

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Kontrola temperature za MCR:
Električni sustavi

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Ćelije za praškove za MCR:
Smična ćelija & protočna ćelija

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Dodatni pribor za CTD 180:
Opcija za vlažnost

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Kontrola temperature - Temperaturni uređaji konvekcijskog tipa (-160 °C do +1000 °C)

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Reo-optika – polarizirano snimanje slike

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Uređaj za mjerenje brzine fotogramom čestica za MCR:
PIV

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Susav za neutronsko ili rendgensko raspršenje pri malom upadnom kutu za MCR:
Rheo-SANS/SAXS

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Više informacija
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci

Accessory for MCR temperature devices:
Low temperature options

Kompatibilan sa:
MCR 102e/302e/502e MCR 102e | MCR 302e | MCR 502e Power
Vrijeme isporuke: %1$s - %2$s radni dani %1$s – %2$s tjedna %1$s – %2$s mjeseci
Detalji o proizvodu
  • Combinable with electric and convection temperature devices
  • Choice of solutions for different low temperature requirements: down to -40 °C, -90 °C, or -160 °C
  • Toolmaster functionality for automatic system configuration and error-proofing

Više informacija