Modular Compact Rheometer:
MCR 102/302/502
- The basic rheometer model: Your entry-ticket into the world of sophisticated rheological research
- Equipped with a renowned EC motor for highly accurate results
- Upgradable according to your future requirements: Further features like TruRate™ (sample adaptive motor controller) and TruStrain™ (real-time position control) optionally available
- The established rheometer reference for R&D and advanced QC testing
- EC motor inside – the key to accuracy
- Adaptable according to your specific needs: Special designs e.g. with exposed support plate for special setups available on request
- The strongest and most versatile rheometer model for special applications
- The integrated EC motor ensures accuracy across a wide viscosity range – from solids to liquids with viscosities lower than water
- Full flexibility: MCR 502 WESP can even be equipped with a linear motor for DMA measurements or extensive microscopy setups
upon request
in specific countries
The MCR rheometer series is the result of continuous development and based on decades of experience in rheology and rheometry. The combination of innovative and thousandfold field-proven technology with the robust design represents the benchmark in its class. Anton Paar rheometers are built for everyday use in the lab and are the key to all possible kinds of rheological investigations and material characterization. The application field of the renowned MCR series ranges from quality control to high-end research and development tasks.
Key features

Unique motor and controller technology
The innovative EC-motor in combination with the low-friction air bearing, the integrated normal force sensor, and a high-resolution optical encoder form the heart of an MCR rheometer. The unique sample-adaptive controller TruRate™ (in rotation and step strain) and the fast and accurate strain control due to improved real-time position control TruStrain™ (in oscillation) guarantee highly precise measurements even at the lowest torques (<2 nNm). The steel frame is optimized for mechanical and thermal stiffness and minimizes torsional and axial compliance. The residual compliance is known and corrected during the measurement, eliminating the need for post-measurement corrections.

Designed for easy handling and error proofing
The open design enables easy and fast sample loading and trimming. The lift motor in the stand provides precise gap setting and compensates gap changes related to temperature and normal force. Due to the QuickConnect coupling, measuring systems can be exchanged with one hand. The patented Toolmaster™ technology ensures automatic recognition of measuring systems and accessories and all relevant parameters are automatically transferred to the software. The TruGap™ feature offers real-time detection of the real measuring gap, ensuring accurate gap settings even when the room temperature changes. T-Ready™ reduces the waiting time by detecting sample temperature equilibration.

Rheometer and operating software in perfect unity
The intuitive RheoCompass software offers predefined as well as customized test templates and analysis definitions. Furthermore, it is possible to export rheological data and generate reports. Data can easily be filtered by e.g. year, batch number, or operator, and displayed within seconds. Due to the Ethernet connection, the rheometer can be remote-controlled from anywhere via the company network. Gap setting, adjustments, and tests can also be started directly from the MCR rheometer, minimizing annoying switches between the computer and the device, e.g. during sample preparation.

Modularity and flexibility to meet all needs
Whatever your rheological applications are and will be in the future – Anton Paar rheometers are quickly and easily adapted to meet your needs. Their flexibility makes them the most cited instruments in scientific publications on rheological investigations. An extensive range of application-specific accessories is available to extend the rheometer’s capabilities, including DMA measurements, extensional rheology, rheo-optics (e.g. microscopy and Raman spectroscopy), magneto- and electrorheology, dielectric spectroscopy, interfacial rheology, UV curing, pressure- and humidity-dependent rheology, tribology, and many more. Temperature accessories in the temperature range from -160 °C to 1000 °C are also available.

Special devices and customized solutions
Special applications demand special and customized solutions. MCR 502 S and MCR 502 WESP offer unique specifications and provide solutions for special demands in the high torque range and for maximum working space and flexibility (e.g. for the combination with a confocal microscope). Based on decades of experience in rheometry and rheology, Anton Paar can make nearly everything possible. Customized products for all kinds of specific applications can be developed and supplied. Don’t hesitate to contact us in order to discuss your requirements and to find a customized solution for your measurement task.
Technical specifications
All instruments of the MCR series are equipped with the Toolmaster™ system for automatic recognition of the measuring system and accessories. All systems are interchangeable between the different models.
Technical Data | Unit | MCR 102 | MCR 302 | MCR 502 S | MCR 502 WESP |
---|---|---|---|---|---|
Bearing | Air | Air | Air | Air | |
EC motor | Yes | Yes | Yes | Yes | |
Maximum torque | mNm | 200 | 200 | 300 | 230 |
Min. torque, rotation | nNm | 5 | 1 | 100 | 1 |
Min. torque, oscillation | nNm | 5d | 0.5 | 100 | 0.5 |
Angular deflection (set value) | µrad | 0.5 to ∞ | 0.05 to ∞ | 0.05 to ∞ | 0.05 to ∞ |
Min. angular velocity | rad/s | 10-8 | 10-9 | 10-9 | 10-9 |
Max. angular velocity | rad/s | 314 | 314 | 220 | 314 |
Max. speed | 1/min | 3000 | 3000 | 2100 | 3000 (6000)a |
Min. angular frequency | rad/s | 10-7 | 10-7 | 10-7 | 10-7 |
Max. angular frequency | rad/s | 628c | 628c | 628c | 628c |
Normal force range | N | 0.01-50 | 0.005-50 | 0.01-70 | 0.005-50 |
Normal force resolution | mN | 1 | 0.5 | 1 | 0.5 |
Max. temperature range | °C | -160 to +1000 | -160 to +1000 | -160 to +1000 | -160 to +1000 |
Toolmaster™ | Yes | Yes | Yes | Yes | |
QuickConnect | - | Yes | Yes | Yes | Yes |
Automatic gap control / setting (AGC/AGS) | - | Yes | Yes | Yes | Yes |
TruGap™ | - | Yes | Yes | Yes | Yes |
MultiDrive-ready | - | No | No | No | Yes |
Direct strain controller | - | Yes | Yes | Yes | Yes |
Direct stress contoller | - | Yes | Yes | Yes | Yes |
TruRate™ | - | Optional | Yes | Yes | Yes |
TruStrain™ | - | Optional | Yes | Yes | Yes |
Normal force profiles (set and read) | - | Yes | Yes | Yes | Yes |
Velocity profiles, tack, squeeze | - | Optional | Yes | Yes | Yes |
Raw data (LAOS, waveform) | - | Optional | Optional | Yes | Yes |
With Exposed Support Plateb | - | No | Optional | No | No |
Without any Support Plateb | - | No | Optional | No | No |
aOptional (with second EC motor) | |||||
*RheoCompass (9177015) is a registered trademark of Anton Paar. |
Standards
A
ASTM D4440ASTM D4473
ASTM D5279
D
DIN 1342 1-3DIN 3219
DIN 13343
DIN 51810 Part 1
DIN 51810 Part 2
DIN 53019-1
DIN 53019-2
DIN 54458
E
EN 3219EN 14770
I
ISO 3219ISO 6721-1
P
Ph. Eur. 0132Ph. Eur. 2.2.8 - Viscosity
Ph. Eur. 2.2.10 - Rotating viscometer method
U
USP 912 - Rotational Rheometer MethodsAnton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Combined rheological methods - From rheo-optics to magneto-rheology and beyond Application Reports en
-
Joe Flow 12 - First aid: Where to turn when nothing turns like it should? Application Reports de, en
-
Joe Flow 20 - Stribeck curves: A powerful screening tool for tribology in a nutshell Application Reports de, en
-
Practically relevant rheological analysis of polymers using a modern rheometer Application Reports en
-
Relaxation time(s) and the relaxation time spectrum H(λ) of a polypropylene melt Application Reports en
-
Rheological Characterization of Ceramic Slurries with the Anton Paar MCR Rheometer Application Reports en
Accessories & Software

Accessories for MCR: Ball Measuring System & Building Material Cell

Accessory for MCR and RheolabQC: Flexible Cup Holder

Accessory for MCR: Electro-Rheological Device

Accessory for MCR: Humidity Option

Accessory for MCR: Immobilization Cell

Accessory for MCR: Interfacial Rheology System

Accessory for MCR: Magneto-Rheological Device

Accessory for MCR: Rheometer geometries

Dielectric Spectroscopy

MCR plus tribology cells: Tribometer

Optical accessory for MCR: UV Light Curing System

Particle Imaging Velocimetry Device for MCR: PIV

Powder Cells for MCR: Shear Cell & Flow Cell

Pressure Cell

RheoOptics - Polarized Imaging

RheoOptics - Rheo-Microscope

Small-Angle Light Scattering Device for MCR: Rheo-SALS

Small-angle neutron or X-ray scattering system for MCR: Rheo-SANS/SAXS

Solid rectangular or circular fixtures for MCR: SRF/SCF

Starch Pasting Measurement for MCR: Starch Cell

Temperature control for MCR: Electrical systems

Temperature control for MCR: Fluid circulators

Temperature control for MCR: Peltier systems

Temperature Control: Convection Temperature Devices (-160 °C to +1000 °C)

Temperature control: Peltier systems with TruGap™