SVM 3001 Cold Properties measures more parameters – including density, viscosity, cloud and freeze point – than any other kinematic viscometer on the market. Enjoy unparalleled flexibility that is also compliant with ASTM D1655, D2880, D7566, DEF STAN 91-091, AFQRJOS, D396, D975, EN ISO 16896, and many other essential standards.

Everything is possible with SVM 3001 Cold Properties.

Get in touch Document Finder

Key Features

Compliance for every sample type

Compliance for every sample type

SVM 3001 Cold Properties complies with a large number of standards and specifications, ensuring fulfillment of the highest product quality requirements. These standards include:

  • Jet fuel (ASTM D1655, Def Stan 91-91, JIG AFQRJOS)
  • Diesel fuel oils (ASTM D975)
  • Biodiesel blends (ASTM D975, ASTM D7467)
  • Fuel oils (ASTM D396, ASTM D6823, ASTM D7666)

With the implemented ASTM-developed bias corrections, you have the ability to report D445 results while enjoying all the benefits of measuring with an SVM according to ASTM D7042.

Flexibility for jet fuel measurements

Flexibility for jet fuel measurements

The exceptional temperature performance of SVM 3001 Cold Properties enables you to reach temperatures as low as -20 °C without the need for external cooling, making it ideally suited for jet fuel certification. Measurement of cloud and freeze point, in addition to kinematic viscosity and density, means that you get all four relevant measurement parameters from a single syringe. Additionally, SVM 3001 Cold Properties provides fast heating and cooling rates of up to 20 °C/minute, enabling time-saving operation and allowing fast temperature scans to investigate the temperature behavior of your samples. This is the ideal kinematic viscometer for not only QC, but also for R&D.

One instrument, unlimited possibilities

One instrument, unlimited possibilities

With its integrated measuring cell, SVM 3001 Cold Properties covers the entire viscosity, density, and temperature range, and gives you the opportunity to measure a wide variety of different samples – not just jet fuel, but also base oils, lubricants, and diesel. The cloud point and freeze point measuring cell provides additional information about cold flow properties of your sample. 

Unprecedented multiparameter measurement

Unprecedented multiparameter measurement

Kinematic viscosity is just one of the parameters you can measure from one syringe. The following parameters are delivered by SVM 3001 Cold Properties according to the latest industry standards, significantly reducing user workload that would otherwise be high due to multiple tests:

  • Kinematic viscosity (ASTM D7042, EN 16896)
  • Density (EN ISO 12185, ASTM D4052)
  • Freeze point (correlation to ASTM D2386)
  • Cloud point (correlation to ASTM D2500)
Unmatched value

Unmatched value

SVM 3001 Cold Properties offers more parameters and delivers more value than any other instrument on the market. Thanks to the unique patented measuring cell design and compact dimensions, the instrument requires only small volumes of solvent for cleaning (min. 1.5 mL). No external counter-cooling is required for measurements at temperatures as low as -20 °C, meaning SVM 3001 Cold Properties also saves your precious lab space. In addition, the low energy consumption of SVM 3001 Cold Properties (max. 250 W) leads to low energy costs and a high level of economic efficiency and sustainability.

Technical Specifications

SVM 2001 SVM 3001 SVM 3001 Cold Properties SVM 4001
Patents granted AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1)
Temperature range +15 °C to +100 °C -60 °C to +135 °C -60 °C to +100 °C +15 °C to +100°C
Viscosity range 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s
Density range 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³
Viscosity repeatability* 0.1 % 0.1 % 0.1 % 0.1 %
Viscosity reproducibility* 0.35 % 0.35 % 0.35 % 0.35 %
Density repeatability* 0.0002 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³
Density reproducibility* 0.0005 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³
Temperature repeatability 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F)
Temperature reproducibility 0.03 °C (0.054 °F) from 15 °C to 100 °C 0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
Cloud point repeatability* - - <0.5 °C -
Cloud point reproducibility* - - <2.5 °C -
Freeze point repeatability* - - <0.5 °C -
Freeze point reproducibility* - - <1.3 °C -
Main standards ASTM D7042, EN 16896 ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
Supported precision classes Ultrafast, Fast and Precise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise
Sample volume min./typical 1.5 mL / 5 mL 1.5 mL / 5 mL 1.5 mL / 5 mL 2.5 mL / 6 mL
Solvent volume min./typical 1.5 mL / 6 mL 1.5 mL / 6 mL 1.5 mL / 6 mL 2.5 mL / 10 mL
Maximum sample throughput 30 samples per hour 30 samples per hour 30 samples per hour 24 samples per hour
Peltier temperature control Designed for constant temperature Designed for fast heating/cooling over a wide range Designed for fast heating/cooling over a wide range Designed for simultaneous measurement at any two different temperatures within the range
Optional automation  
  • Non-heated: Single syringe (5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling 
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling 
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12 mL)
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling
 
Wetted parts Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
O-rings in contact with sample Viton ® Extreme Kalrez ® Spectrum 0040 Kalrez ® Spectrum 0040 Viton ® Extreme
Data memory 1000 measurement results 1000 measurement results 1000 measurement results 1000 measurement results
HID (Human Interface Device)  
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse, and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
Interfaces  
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
Power supply  
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
Ambient conditions 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing
Net weight/shipping weight 15.9 kg/20.5 kg 17.6 kg/22.2 kg 18.0 kg/22.6 kg 17.8 kg/22.4 kg
Dimensions (W x D x H) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)
Compliance  
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
Special features Optional automation, Automatic VI method Automatic VI method, API calculations, temperature scans, FillingCheck™.

Optional: Counter cooling, automation, modularity with Abbemat refractometers
Automatic VI method, API calculations, temperature scans, FillingCheck™.

Optional: Counter cooling, automation
Double measurement cells for simultaneous viscosity and density measurement at any two different temperatures in the range, VI method, API calculations, FillingCheck™.

Optional: Automation, modularity with Abbemat refractometers

*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards. Valid for ideal measuring and sample conditions within the works adjustment range.

All data refers to stand-alone instruments.
For more information, please contact your Anton Paar representative.

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
Learn more

Documents

Similar products