This is a required field.

Kinematic viscometers:
SVM

Model:
  • Temperature range from 15 °C to 100 °C
  • The most economic automated kinematic viscometer
  • Compliant to ASTM D396, D975, D3699, D6158, D6823, D7467, and more
  • Easy handling without glass breakage
  • Fast solution even for sticky samples such as used oil
  • Widest temperature range from -60 °C to 135 °C
  • All samples, from jet fuel to wax, without changing the capillary
  • Compliant to ISO 23581, EN 16896, ASTM D396, D975, D7666, and more
  • Down to -20 °C without counter-cooling
  • Fast heating and cooling rates of up to 20 °C/min
  • Temperature range from -60 °C to +100 °C
  • Kinematic viscosity, density, cloud and freeze point from one test
  • Viscosity borderline temperature (temperature at 12 cSt)
  • ASTM D1655, D2880, D7566, D975, D7467, JIG AFQRJOS, results equivalent to ASTM D2386 and ASTM D2500
  • Temperature range from 15 °C to 100 °C
  • Fastest viscosity index acc. to ASTM D2270 from min. 2.5 mL sample
  • Simultaneous viscosity and density results at any 2 temperatures
  • From base oil, additives, blends, and used oil to wax and grease without changing the capillary
excl.incl. 0VAT
Price
upon request
Purchasable online
in specific countries
Buy Anton Paar instruments online
Part number:
Check online availability Get a quote Buy this product online
Delivery time: %1$s – %2$s days %1$s – %2$s weeks %1$s – %2$s months

Exchange all your capillaries for one single unit and save enormous amounts of time and money: the SVM viscometers provide the highest flexibility by covering the entire viscosity, density, and temperature range with a single measurement cell and deliver results in seconds. With SVM you can certify jet fuel, diesel, biodiesel blends, and marine fuels; classify crude oils and determine the VI of your lubricant. Whatever challenge you face, the SVM viscometer is the best solution on the market.

Key features

Don’t worry – be compliant

Don’t worry – be compliant

The SVM smart viscometers comply with a multitude of international standards and product specifications. With the integrated bias corrections delivered by ASTM, you can even report in D445 results while enjoying all the benefits of measuring with an SVM.

See standards >>

The highest flexibility for every application

The highest flexibility for every application

Tired of looking for the suitable capillary which fits your sample's viscosity? With SVM you do not need multiple baths and capillaries to measure different samples. SVM covers the entire viscosity, density, and temperature range with one measurement cell, enabling you to measure a wide variety of samples, from jet fuel to wax, without changing the cell. A single SVM viscometer is all you need for kinematic viscosity and viscosity index measurements in the range from 0.2 mm²/s to 30,000 mm²/s.

One instrument – many parameters

One instrument – many parameters

Besides viscosity, you can determine multiple other parameters with SVM within the same run and reduce your workload significantly:

  • Kinematic viscosity (ASTM D7042, EN 16896, DIN 51659-2)
  • Density (EN ISO 12185, ASTM D4052, IP 365)
  • Viscosity index (VI) (ASTM D2270)
  • Dynamic viscosity (ASTM D7042)
  • API grades (ISO 91, API 2540, ASTM D1250, IP 200)

and more.

The highest economic efficiency

The highest economic efficiency

SVM helps you cut operational costs. The patented measuring cell requires only a small amount of solvent for cleaning (min. 1.5 mL), reducing solvent and disposal costs to a minimum. No external cooling is required for measurements down to -20 °C, saving valuable lab space and energy. While delivering superior performance, SVM consumes much less energy than a typical capillary bath, regardless of whether you measure at -20 °C or at +135 °C. Using a sample changer gives you time to perform other important tasks while filling, measuring, and cleaning are taken care of. As a result of these savings, SVM is undoubtedly the most economic and sustainable kinematic viscometer available on the market with the best ROI.

Great results with little effort

Great results with little effort

Installation, operation, and maintenance of SVM are incredibly easy. It is a stand-alone instrument and all calculations are performed automatically by the integrated PC. The factory-adjusted instrument is ready to use immediately out of the box. Thanks to its patented motor concept, access to the measuring cell is tool-free, enabling convenient cleaning after measuring heavily contaminated samples, such as used oil. The optional magnetic particle trap removes magnetic particles from the sample, ensuring good viscosity measurements. The fully customizable user interface shows you exactly the parameters you need. 

Your 4-in-1 solution for low-temperature applications

Your 4-in-1 solution for low-temperature applications

In addition to kinematic viscosity and density, SVM 3001 Cold Properties determines the cloud and freeze points from the same sample. This significantly reduces your workload as SVM delivers the results which would otherwise require multiple tests on different instruments. SVM 3001 Cold Properties is the perfect choice for measuring diesel, biodiesel, and jet fuel and is ideal for both QC and R&D.

Technical specifications

SVM 2001 SVM 3001 SVM 3001 Cold Properties SVM 4001
Patents granted AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1)
Temperature range +15 °C to +100 °C -60 °C to +135 °C -60 °C to +100 °C +15 °C to +100°C
Viscosity range 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s
Density range 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³
Viscosity repeatability* 0.1 % 0.1 % 0.1 % 0.1 %
Viscosity reproducibility* 0.35 % 0.35 % 0.35 % 0.35 %
Density repeatability* 0.0002 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³
Density reproducibility* 0.0005 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³
Temperature repeatability 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F)
Temperature reproducibility 0.03 °C (0.054 °F) from 15 °C to 100 °C 0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
Main standards ASTM D7042, EN 16896 ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
Supported precision classes Ultrafast, Fast and Precise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise
Sample volume min./typical 1.5 mL / 5 mL 1.5 mL / 5 mL 1.5 mL / 5 mL 2.5 mL / 6 mL
Solvent volume min./typical 1.5 mL / 6 mL 1.5 mL / 6 mL 1.5 mL / 6 mL 2.5 mL / 10 mL
Maximum sample throughput 30 samples per hour 30 samples per hour 30 samples per hour 24 samples per hour
Peltier temperature control Designed for constant temperature Designed for fast heating/cooling over a wide range Designed for fast heating/cooling over a wide range Designed for simultaneous measurement at any two different temperatures within the range
Optional automation  
  • Non-heated: Single syringe (5 mL or 10 mL) or 35 vials (45 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 35 vials (45 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 35 vials (45 mL) or 71 vials (12 mL)
 
 
  • Non-heated: Single syringe (5 mL or 10 mL) or 35 vials (45 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling
 
Wetted parts Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel ®
 
O-rings in contact with sample Viton ® Extreme Kalrez ® Spectrum 0040 Kalrez ® Spectrum 0040 Viton ® Extreme
Data memory 1000 measurement results 1000 measurement results 1000 measurement results 1000 measurement results
HID (Human Interface Device)  
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse, and 2D bar code reader
 
 
  • Touchscreen
  • Optional keyboard, mouse and 2D bar code reader
 
Interfaces  
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
 
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
 
Power supply  
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
 
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
 
Ambient conditions 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing
Net weight/shipping weight 15.9 kg/20.5 kg 17.6 kg/22.2 kg 18.0 kg/22.6 kg 17.8 kg/22.4 kg
Dimensions (W x D x H) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)
Compliance  
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 
 
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
 

*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards. Valid for ideal measuring and sample conditions within the works adjustment range.

All data refers to stand-alone instruments.
For more information, please contact your Anton Paar representative.

Standards

A

ANP Nº 804
API 2540
ASTM D341
ASTM D396
ASTM D975
ASTM D1250
ASTM D1655
ASTM D2161
ASTM D2270
ASTM D2501
ASTM D2502
ASTM D2603
ASTM D2880
ASTM D3238
ASTM D3238
ASTM D3699
ASTM D4052
ASTM D4054
ASTM D4174
ASTM D4378
ASTM D5002
ASTM D5275
ASTM D5372
ASTM D5621
ASTM D6074
ASTM D6080
ASTM D6158
ASTM D6278
ASTM D6287
ASTM D6448
ASTM D6666
ASTM D6710
ASTM D6751
ASTM D6823
ASTM D7042
ASTM D7109
ASTM D7152
ASTM D7155
ASTM D7223
ASTM D7467
ASTM D7566
ASTM D7665
ASTM D7666
ASTM D7720
ASTM D7752
ASTM D7826
ASTM D7863
ASTM D7973
ASTM D8029
ASTM D8046
ASTM D8128
ASTM D8147
ASTM D8181
ASTM D8185
ASTM F3208
ASTM F3337

C

CPTC SH/T 0604-2000 eqv. ISO 12185

D

DEFSTAN 91-91
DIN 51659-2

E

EN 16766
EN 16896
EN 141214-2019

G

GB T 29617
GJB 9131
GOST 33

I

IP 200
IP 365
IP 626
IS 1460
IS 1571
ISO 91
ISO 2909
ISO 12185

J

JIG AFQRJOS

M

MIL DTL-83133J
MIL PRF-17331L

O

OENORM C1109

S

SH T 0870
SN T 3518

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Accessories & Software

Your choice: Reset all filters X
Industry
Applications
Standards
Showing to of