Recommended Results

Kinematic viscometer: SVM 3001

Wide-range viscometer for unparalleled flexibility

Whether you want to certify jet fuel or diesel, measure lubricants or heavy fuels, or classify crude oil, SVM 3001 is the best solution for your application. All samples can be measured with one integrated cell from -60 °C to + 135 °C. The Peltier temperature control enables fast heating and cooling rates and the embedded PC provides a wide range of automatic calculations including bias-corrected ASTM D445 results, API grades, viscosity index, and more.

Enjoy unlimited applications with the power of SVM 3001.

Get in touch Document Finder

Key Features

Experience the all-rounder for a wide temperature range

Experience the all-rounder for a wide temperature range

The outstandingly wide temperature range of SVM 3001 (from -60 °C to +135 °C) enables you to use the instrument as a low- and high-temperature viscometer. Temperatures down to -20 °C can be reached without external cooling, making it ideally suited for jet fuel certification. Additionally, SVM 3001 provides fast heating and cooling rates of up to 20 °C/min, enabling time-saving operation and exceptionally fast temperature scans to investigate the temperature behavior of your samples.

One measuring cell – all samples

One measuring cell – all samples

With SVM 3001, there is no need for multiple baths and capillaries to measure different samples. Get all the flexibility you need in a single instrument. With only one measuring cell, SVM 3001 covers the entire viscosity, density, and temperature range, enabling you to measure a wide variety of samples. Benefit from the most flexible viscometer on the market.

Multiparameter measurement

Multiparameter measurement

Besides viscosity you can determine multiple other parameters from just one syringe and reduce your workload to a minimum. Need to classify your crude oils according to API grades? SVM 3001 has you covered. Parameters measured by SVM 3001 comply with the following industry standards:

  • Kinematic viscosity (ASTM D7042, EN 16896, DIN 51659-2)
  • Density (EN ISO 12185, ASTM D4052, IP 365)
  • Dynamic viscosity (ASTM D7042)
  • API grades (ISO 91, API 2540, ASTM D1250, IP 200)
  • Viscosity index (VI) (ASTM D2270)
Full compliance with all necessary specifications

Full compliance with all necessary specifications

SVM 3001 complies with a multitude of standards and specifications, fulfilling all necessary regulations in order to ensure that highest product quality requirements are met. These include:

  • Jet fuel (ASTM D1655, Def Stan 91-91, JIG AFQRJOS)
  • Diesel fuel oils (ASTM D975)
  • Biodiesel blends (ASTM D975, ASTM D7467)
  • Fuel oils (ASTM D396, ASTM D6823, ASTM D7666)

With the implemented bias corrections (developed by ASTM), the user can report D445 results while enjoying all the benefits of measuring with an SVM according to ASTM D7042.

Cost-effectiveness and sustainability at its best

Cost-effectiveness and sustainability at its best

In addition to its unparalleled flexibility, SVM 3001 also helps you cut solvent and disposal costs. Thanks to the unique patented measuring cell design, the instrument requires only small volumes of solvent for cleaning (min. 1.5 mL). As no external cooling device is required for measurements at temperatures as low as -20 °C, SVM 3001 also saves valuable lab space. While delivering superior temperature performance, the SVM viscometer consumes much less energy than a typical capillary bath, regardless of whether you are measuring jet fuel viscosity at -20 °C or wax viscosity at +135 °C. As a result, the smart viscometer provides you with the best ROI on the market.

Technical Specifications

SVM 2001 SVM 3001 SVM 4001
Patents granted AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1)
Temperature range +15 °C to +100 °C -60 °C to +135 °C +15 °C to +100°C
Viscosity range 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s
Density range 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³
Viscosity repeatability* 0.1 % 0.1 % 0.1 %
Viscosity reproducibility* 0.35% 0.35% 0.35%
Density repeatability* 0.0002 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³
Density reproducibility* 0.0005 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³
Temperature repeatability 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F)
Temperature reproducibility 0.03 °C (0.054 °F) from 15 °C to 100 °C 0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
Main standards ASTM D7042, EN 16896 ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
Supported precision classes Ultrafast, Fast and Precise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise
Sample volume min./typical 1.5 mL / 5 mL 1.5 mL / 5 mL 2.5 mL / 6 mL
Solvent volume min./typical 1.5 mL / 6 mL 1.5 mL / 6 mL 2.5 mL / 10 mL
Maximum sample throughput 30 samples per hour 30 samples per hour 24 samples per hour
Peltier temperature control Designed for constant temperature Designed for fast heating/cooling over a wide range Designed for simultaneous measurement at any two different temperatures within the range
Optional automation
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
Wetted parts Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
O-rings in contact with sample Viton® Extreme Kalrez® Spectrum 0040 Viton® Extreme
Data memory 1000 measurement results 1000 measurement results 1000 measurement results
HID (Human Interface Device)
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
Interfaces
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
Power supply
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
Ambient conditions 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing
Net weight/shipping weight 15.9 kg/20.5 kg 17.6 kg/22.2 kg 17.8 kg/22.4 kg
Dimensions (W x D x H) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)
Compliance
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
Special features Optional automation, Automatic VI method Automatic VI method, API calculations, temperature scans, FillingCheck™.

Optional: Countercooling, automation, modularity with Abbemat refractometers
Double measurement cells for simultaneous viscosity and density measurement at any two different temperatures in the range, VI method, API calculations, FillingCheck™.

Optional: Automation, modularity with Abbemat refractometers

*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards. Valid for ideal measuring and sample conditions within the works adjustment range.

All data refer to stand-alone instruments.
For more information, please contact your Anton Paar representative.

Standards

A

API 2540
ASTM D1250
ASTM D1655
ASTM D2161
ASTM D2270
ASTM D2501
ASTM D2502
ASTM D2880
ASTM D396
ASTM D4052
ASTM D5002
ASTM D6074
ASTM D6448
ASTM D6823
ASTM D7042
ASTM D7152
ASTM D7566
ASTM D975
ASTM D7666
ASTM D4054
ASTM D7720
ASTM D8046
ASTM D7223
ASTM D341
ASTM D3238
ASTM D5372
ASTM D6710
ASTM D7665
ASTM D7863
ASTM D4174
ASTM D7826
ASTM D8128
ASTM F3208
ASTM D8147
ASTM D7752
ASTM D8185
ASTM D7155
ASTM D8181
ASTM F3337

C

CPTC SH/T 0604-2000 eqv. ISO 12185

D

DIN 51659-2
DEFSTAN 91-91

E

EN 16896
EN 16766
EN 141214-2019

G

GB T 29617
GJB 9131

I

IP 200
IP 365
ISO 12185
ISO 2909
ISO 91
IS 1460
IS 1571

J

JIG AFQRJOS

M

MIL DTL-83133J
MIL PRF-17331L

S

SH T 0870
SN T 3518

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
Learn more

Documents

Accessories

Your choice: Reset all filters X
Industry
Industry Group
Standards
Showing to of

Similar products