Recommended Results

Kinematic viscometer: SVM 2001

The most economic kinematic viscometer for a large variety of samples

SVM 2001 allows for easy and fast viscosity measurements from 15 °C to 100 °C, from fuels and lubes to used oils. Simply fill the sample from a syringe and start the measurement to get the results within a few minutes. Cover the full viscosity range from 0.2 mm²/s to 30 000 mm²/s with one single measurement cell – no need to change capillaries. For easy cleaning and maintenance, the measurement cell is accessible for cleaning without any tools thanks to its patented design.

Get in touch Document Finder

Key Features

Viscosity measurement made easy

Viscosity measurement made easy

When testing diverse samples like used oils, finding the appropriate capillary can be a tedious task due to their limited viscosity range. SVM 2001 on the other hand covers the entire viscosity, density, and temperature range with one single measuring cell, turning the search for the right capillaries into a thing of the past. Even the viscosity index (VI) of lubricants and in-service oils can be measured from one syringe within a single measuring cycle. Inject your sample and SVM 2001 does the rest, measuring at two different temperatures successively and automatically calculating the VI.

Eco-friendliness at an affordable price

Eco-friendliness at an affordable price

SVM 2001 offers great value to price-conscious users, while still outperforming all competitors on the market.

Not only does SVM 2001 make viscosity measurements smart and simple, it also requires just a small volume of sample and solvent for cleaning (min. 1.5 mL), which lowers solvent and disposal costs. In contrast to glass capillary viscometers, the high-performance kinematic viscometer SVM 2001 does not require a liquid bath and cooling equipment, meaning it saves energy and space.

Great results with little effort

Great results with little effort

Installation, operation, and maintenance of SVM 2001 are incredibly easy. The factory-adjusted instrument is ready to measure immediately after start-up. Thanks to the patented motor concept, access to the measuring cell is tool-free, which enables convenient cleaning when measuring heavily contaminated samples, such as used oils. The optional magnetic particle trap removes magnetic particles from the sample, ensuring good quality measurements.

Technical Specifications

SVM 2001 SVM 3001 SVM 4001
Patents granted AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1) AT516058 (B1), AT516302 (B1)
Temperature range +15 °C to +100 °C -60 °C to +135 °C +15 °C to +100°C
Viscosity range 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s 0.2 mm²/s to 30 000 mm²/s
Density range 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³ 0.6 g/cm³ to 3 g/cm³
Viscosity repeatability* 0.1 % 0.1 % 0.1 %
Viscosity reproducibility* 0.35% 0.35% 0.35%
Density repeatability* 0.0002 g/cm³ 0.00005 g/cm³ 0.00005 g/cm³
Density reproducibility* 0.0005 g/cm³ 0.0001 g/cm³ 0.0001 g/cm³
Temperature repeatability 0.005 °C (0.009 °F) 0.005 °C (0.009 °F) 0.005 °C (0.009 °F)
Temperature reproducibility 0.03 °C (0.054 °F) from 15 °C to 100 °C 0.03 °C (0.054 °F) from 15 °C to 100 °C
0.05 °C (0.09 °F) outside this range
0.03 °C (0.054 °F) from 15 °C to 100 °C
Main standards ASTM D7042, EN 16896 ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
Supported precision classes Ultrafast, Fast and Precise Ultrafast, Fast, Precise and Ultraprecise Ultrafast, Fast, Precise and Ultraprecise
Sample volume min./typical 1.5 mL / 5 mL 1.5 mL / 5 mL 2.5 mL / 6 mL
Solvent volume min./typical 1.5 mL / 6 mL 1.5 mL / 6 mL 2.5 mL / 10 mL
Maximum sample throughput 30 samples per hour 30 samples per hour 24 samples per hour
Peltier temperature control Designed for constant temperature Designed for fast heating/cooling over a wide range Designed for simultaneous measurement at any two different temperatures within the range
Optional automation
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
  • Non-heated: Single syringe (2 mL, 5 mL or 10 mL) or 45 vials (35 mL) or 71 vials (12mL)
  • Heated: 36 vials (12 mL) or single sample filling (from 12 mL vial)
Wetted parts Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
Inside the instrument:
  • Copper
  • Titanium
  • Stainless steel A4
  • Inconel®
O-rings in contact with sample Viton® Extreme Kalrez® Spectrum 0040 Viton® Extreme
Data memory 1000 measurement results 1000 measurement results 1000 measurement results
HID (Human Interface Device)
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
  • Touchscreen
  • optional keyboard, mouse and 2D bar code reader
Interfaces
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
  • 4 x USB (2.0 full speed)
  • 1 x Ethernet (100 Mbit)
  • 1 X CAN bus
  • 1 x RS-232; 1 x VGA
Power supply
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
  • AC 100 V to 240 V
  • 50 Hz to 60 Hz
  • 250 VA max
Ambient conditions 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing
Net weight/shipping weight 15.9 kg/20.5 kg 17.6 kg/22.2 kg 17.8 kg/22.4 kg
Dimensions (W x D x H) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)
Compliance
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
  • CE mark
  • EMC directive EN 61326-1
  • LV directive EN 61010-1
  • RoHS
Special features Optional automation, Automatic VI method Automatic VI method, API calculations, temperature scans, FillingCheck™.

Optional: Countercooling, automation, modularity with Abbemat refractometers
Double measurement cells for simultaneous viscosity and density measurement at any two different temperatures in the range, VI method, API calculations, FillingCheck™.

Optional: Automation, modularity with Abbemat refractometers

*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards. Valid for ideal measuring and sample conditions within the works adjustment range.

All data refer to stand-alone instruments.
For more information, please contact your Anton Paar representative.

Standards

A

ASTM D2161
ASTM D2502
ASTM D2880
ASTM D396
ASTM D6074
ASTM D6448
ASTM D6823
ASTM D7042
ASTM D7152
ASTM D975
ASTM D7666
ASTM D7720
ASTM D8046
ASTM D341
ASTM D5372
ASTM D6710
ASTM D7665
ASTM D7863
ASTM D4174
ASTM D8128
ASTM F3208
ASTM D7752
ASTM D8185
ASTM D7155
ASTM D8181
ASTM F3337

D

DIN 51659-2

E

EN 16896
EN 16766
EN 141214-2019

G

GB T 29617
GJB 9131

I

IS 1460

M

MIL PRF-17331L

S

SH T 0870
SN T 3518

Documents

Accessories

Your choice: Reset all filters X
Industry
Industry Group
Standards
Showing to of