MCR 703 MultiDrive and MCR 703 Space MultiDrive are the most versatile advanced rheometers available. Alongside all the standard features of the MCR 503, they can also be equipped with an additional lower drive unit. This means you can perform rheological tests with two torque transducers and drive units at once, opening up multiple possibilities for your research. There are no limitations regarding test modes, measuring systems, accessories, temperature devices, and measurement precision. Additionally, MCR 703 Space MultiDrive offers maximum working space, making it easy to work with accessories and additional instruments.
Key features
One rheometer, all rheological working modes
This is the perfect rheometer for advanced measurement-precision requirements. A combination of two drive units enables you to perform rheological measurements in Combined Motor Transducer (CMT) mode and in Separate Motor Transducer (SMT) mode. Using a single air-bearing-supported EC motor in CMT mode, you can make the most of the motor’s real-time position control (TruStrain) and perform ‘classic’ stress-controlled tests. In SMT mode, one motor is operated solely as a torque transducer, while the other is used as the drive unit to get the purest results. This makes the advanced rheometer ideal even for transient regimes such as stress relaxation, start-up shear measurements, or oscillatory tests across a wide frequency range.
* Measuring ** Driving
Push the limits of material characterization
In counter-movement mode, the advanced rheometer employs both air-bearing-supported EC motors as drive units, as well as torque transducers which move in opposite directions. Create, for example, a fixed stagnation plane in a sample while visualizing with a microscope for advanced structure analysis throughout the full measurement. In combination with the universal extensional fixture, this mode also permits extensional tests down to minimal measured torques and up to unachieved elongations with Hencky strains larger than eight. With these capabilities, this advanced rheometer offers more comprehensive characterization of strain hardening. The counter-movement mode simply doubles the speed score up to a maximum speed difference of 6,000 rpm.
DMA in torsion, tension, bending, compression, and more
MCR 703 is more than just a rotational rheometer – it’s a multifunctional advanced rheometer that also supports dynamic mechanical analysis (DMA). By replacing the lower rotational drive with a linear drive, it performs DMA in bending or compression using geometries such as three-point-bending, cantilever, or parallel plates. Furthermore, in combination with geometries for films, fibers, and rectangular and cylindrical samples, the linear drive can be used to perform DMA in tension, while the upper rotational drive is used for DMA in torsion. This also enables axial-torsional DMA on a single specimen within a single test definition, and allows determination of the Poisson’s ratio and fast direction-dependent characterization of anisotropic materials.
Previously unthinkable applications
MCR 703 Space MultiDrive takes the exceptional performance of our flagship rheometer MCR 703 MultiDrive even further. It's engineered to offer unique modularity, flexibility, freedom, and functionality for any type of rheology and combined methods. The open instrument design maximizes working space so you can connect MCR 703 Space MultiDrive with a variety of additional external setups for advanced material characterization (e.g., confocal microscopy and rheology at the same time). In addition, the rheometer's separate electronics box now makes it possible to set up the rheometer where space is limited or in a laboratory glovebox, even when using inert gas (nitrogen, argon) atmosphere (e.g., for high-temperature measurements of samples with a certain hazard level).
More than 200 accessories
MCR 703 MultiDrive and MCR 703 Space MultiDrive can be paired with any measuring system, temperature device, and/or application-specific accessory recognizable from the Anton Paar MCR series, in order to carry out standard and sophisticated rheological analyses. This allows the testing platform to be used not only for rheology and DMA but also as a powder rheometer, tribometer, and universal testing machine. The Toolmaster feature automatically recognizes and configures all connected devices and measuring systems. Additionally, the QuickConnect function allows one-handed connection of the measuring systems. This modularity makes our advanced rheometers highly flexible and ensures that adaption of the configuration to your needs is straightforward.
Specifications
MCR 703 MultiDrive MCR 703 Space MultiDrive
Configuration with 1 EC motor
Configuration with 2 EC motors
Bearing design
Air, fine-pored carbon
Motor design
Electronically commutated (EC) permanent magnet synchronous motor
Displacement transducer
High-resolution optical encoder
Normal force measurement design
360° capacitive sensor, non-contacting, fully integrated in bearing
Working modes
CMT
CMT, SMT, Counter-Movement1)
Min. torque (rotation)
1 nNm
1 nNm
Min. torque (oscillation)
0.2 nNm
0.2 nNm
Max. torque
230 mNm
230 mNm
Torque resolution
0.05 nNm
0.05 nNm
Angular deflection resolution
< 1 nrad
Min. angular velocity2)
0 rad/s
Max. angular velocity / max. speed
314 rad/s 3,000 rpm
628 rad/s 6,000 rpm
Min. frequency3)
2 Hz x 10-8 Hz
Max. frequency
200 Hz
Normal force range
0.001 N to 50 N
TruStrain
✓
✓
Ready for DMA in tension, bending, and compression
✓
✓
Ready for axial-torsional DMA4)
✓
✓
Active thermal management of motor
✓
✓
With exposed support plate5)
✓
✓
Dimensions (W x H x D)
MCR 703 MultiDrive: 453 mm x 775 mm x 673 mm MCR 703 Space MultiDrive: 300 mm x 775 mm x 584 mm Electronic box: 333 mm x 231 mm x 576 mm
Weight
MCR 703 MultiDrive: 50 kg MCR 703 Space MultiDrive: 52 kg Electronic box: 16 kg
MCR 703 MultiDrive: 60 kg MCR 703 Space MultiDrive: 62 kg Electronic box: 16 kg
1) US Pat. 8453496 2) In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode depending on measuring point duration and sampling rate. 3) Theoretical value (duration per cycle = 2 years). 4) US Pat. 9574983 and US Pat. 10908058. 5) MCR 703 Space MultiDrive: Unique maximized workspace below the rheometer support plate and on both sides of the instrument
Standards
Open all
Close all
ASTM
D4440
D4473
D5279
DIN
1342 1-3
3219
13343
51810 Part 1
51810 Part 2
53019-1
53019-2
54458
DIN EN ISO
8130-15:2024-01
EN
3219
14770
ISO
3219
6721-1
European Pharmacopoeia (Ph. Eur.)
2.2.8. Viscosity
2.2.10. Viscosity - Rotating viscometer method
0132
US Pharmacopoeia (USP)
912 - Viscosity - Rotational Methods
Standards
Open all
Close all
ASTM
D4440
D4473
D5279
DIN
1342 1-3
3219
13343
51810 Part 1
51810 Part 2
53019-1
53019-2
54458
DIN EN ISO
8130-15:2024-01
EN
3219
DIN EN
14770
ISO
3219
6721-1
European Pharmacopoeia (Ph. Eur.)
2.2.8. Viscosity
2.2.10. Viscosity - Rotating viscometer method
0132
US Pharmacopoeia (USP)
912 - Viscosity - Rotational Methods
Anton Paar Certified Service
The Anton Paar quality in service and support:
More than 350 manufacturer-certified technical experts worldwide
Qualified support in your local language
Protection for your investment throughout its lifecycle
Designed to store:
- Up to 6 measuring systems
- Air bearing protection MCR XX3
- Double spatula, bent
- Torx screwdriver T8
- Allen Wrench 4mm
- Angled Torx screwdrivers T10 and T20
- Open-end wrench S-LP, size 63 mm
- Up to 2 business cards
MEAS. CYLINDER B-DG42
Compatible with
:
MCR 703
MultiDrive | Space MultiDrive
We use cookies on our website. Some of them are necessary (e.g. for the shopping cart), others help us make our online content better and easier for you over the long term via analysis, external media, and marketing services. We also use third-party cookies from providers in the USA like Google or Facebook if provided with your consent (Art. 49(1)(a) GDPR). Your data may be transferred to the USA which does not have a data protection level comparable to GDPR. In this case your data may potentially be accessed by US Authorities for surveillance purposes and you may not be able to exercise effective legal remedies. You can accept or reject all cookies by clicking on the respective button or define your cookie settings using the link "Customize your cookie settings".
If you reject all cookies, only technically required cookies will be used. You can also withdraw your consent at a later time by accessing the Cookie Settings.
Marketing cookies are used by third parties or publishers to show you personalized advertising. They do this by tracking which websites visitors go to.
Content from video platforms and social media platforms is blocked by default. If you accept cookies from external media, accessing these contents no longer requires giving manual consent.
After being informed of potential risks for my data (including transfer to the USA and potential access by US authorities) in the Cookie Banner and Privacy Policy I accept the cookies from US-providers.