Recommended Results

  • SVM™ Product Series
  • Expect More - all parameters at one glance

SVM™ Series

Expect More – Welcome to New Viscometry

The SVM™ series gives you more parameters than any other kinematic viscometer on the market. There are three different models: SVM™ 2001 is a quick and easy-to-use viscometer for measuring kinematic viscosity at any temperature between 15 °C and 100 °C, whereas SVM™ 3001 provides measurements between -60 °C and +135 °C. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity, Viscosity Index and more. SVM™ 4001 is a double-cell instrument especially tailored for simultaneous measurements of viscosity and density at two different temperatures. It automatically provides the Viscosity Index from only a small amount of sample. Different accessories, such as automated samplers or a hot filling attachment, and modularity options are available for the series.

 

 

Get in touch

Key Features

Multiple parameter measurement

SVM™ provides our customers with an exceptional solution that is unique on the market: The possibility to not only measure viscosity, but multiple parameters from only one syringe. From kinematic and dynamic viscosity to density measurements and more – the possibilities are vast. Each parameter measured by SVM™ 3001 or SVM™ 4001 complies with the following industry standards:

  • Kinematic viscosity (ASTM D7042, EN 16896, DIN 51659-2)
  • Density (EN ISO 12185, ASTM D4052, IP 365)
  • Dynamic viscosity (ASTM D7042)
  • Viscosity Index (VI) (ISO 2909, ASTM D2270)
  • API grades (ISO 91, API 2540, ASTM D1250, IP 200)
  • Saybolt viscosity (ASTM D2161)

Unbeatable ease of operation

The SVM™ series stands out for its unbeatable ease of operation, from the initial start-up to the maintenance of the instruments. The devices come factory-adjusted, which means they are ready for immediate use. The measurement is started by simply injecting the sample from a syringe. The SVM™ instruments guarantee safe and easy handling during the measurement procedure, without leaks or breakage. In addition, easy cleaning with a wash bottle simplifies the work.

Low sample and solvent volume

An outstanding feature of the SVM™ series is the small amount of sample and solvent volume required to obtain precise measurement results. This not only simplifies the measuring procedure, but also lowers costs the minimum sample volume is only 1.5 mL and the amount of solvent needed for cleaning is low. Disposal costs can therefore be considerably reduced. Therefore, these SVM™ instruments not only impress with their performance, but also with their sustainability.

Wide temperature range

The instruments of our SVM™ series provide a wide temperature range for both viscosity and density. SVM™ 3001 comes with a range from -60 °C to +135 °C for measuring jet fuel and diesel fuel as well as lubricating oil and wax – with only one integrated cell. Temperatures down to -20 °C can be reached with built-in air cooling (without external cooling), whereas temperatures as low as -60 °C are reached by using external cooling with water/glycol mixtures; no flammable liquids are required. SVM™ 4001 is designed to determine viscosity and density simultaneously at any two temperatures between 15 °C and 100 °C.

One measuring cell – all samples

The SVM™ instruments have one measuring cell for the entire viscosity, density, and temperature range and the sample is measured in one go. This means that samples of different viscosity, such as jet fuels, lubricating oils, heavy fuels and waxes, can all be tested with one integrated measuring cell, which is especially relevant for testing laboratories. In addition, SVM™ 3001 enables you to perform temperature scans and gain knowledge of the sample’s behavior such as low temperature fluidity. Connecting the SVM™ with the 71-position sample changer means you are free to perform other important tasks.

Technical Specifications

SVM™ 2001SVM™ 3001SVM™ 4001
Temperature range+15 °C to +100 °C-60 °C to +135 °C+15 °C to +100°C
Viscosity range0.2 mm²/s to 30 000 mm²/s
Density range0.6 g/cm³ to 3 g/cm³
Main standardsASTM D7042, EN 16896ASTM D7042, EN 16896
ASTM D4052, ISO 12185
ASTM D7042, EN 16896
ASTM D4052, ISO 12185
Supported precision classesUltrafast, Fast and PreciseUltrafast, Fast, Precise and UltrapreciseUltrafast, Fast, Precise and Ultraprecise
Sample volume min./typical1.5 mL / 5 mL1.5 mL / 5 mL2.5 mL / 6 mL
Solvent volume min./typical1.5 mL / 6 mL1.5 mL / 6 mL2.5 mL / 10 mL
Maximum sample throughput30 samples per hour24 samples per hour
Peltier temperature controlDesigned for constant temperatureDesigned for fast heating/cooling over a wide rangeDesigned for simultaneous measurement at any two different temperatures within the range
Optional automationSingle syringe (5 mL or 10 mL) or 45 vials with 35 mL or 71 vials with 12mL
Wetted partsInside the instrument: Copper, Titanium, Stainless steel A4, Inconel®
O-rings in contact with sampleViton® ExtremeKalrez® Spectrum 0040 Viton® Extreme
Data memory1000 measurement results
HID (Human Interface Device)Touchscreen; optional keyboard, mouse and 2D bar code reader
Interfaces4 x USB (2.0 full speed); 1 x Ethernet (100 Mbit); 1 X CAN bus; 1 x RS-232; 1 x VGA
Power supplyAC 100 V to 240 V; 50 Hz to 60 Hz; 250 VA max.
Ambient conditions15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing
Net weight/shipping weight15.9 kg/20.5 kg17.6 kg/22.2 kg17.8 kg/22.4 kg
Dimensions (W x D x H)33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in)
ComplianceCE mark; EMC directive EN 61326-1; LV directive EN 61010-1; RoHS
Special featuresOptional automationAutomatic VI method, API calculations, temperature scans, FillingCheck™. Optional: Countercooling, automation, modularity with Abbemat refractometersDouble measurement cells for simultaneous viscosity and density measurement at any two different temperatures in the range, VI method, API calculations, FillingCheck™. Optional: Automation, modularity with Abbemat refractometers

For more information, please contact your Anton Paar representative.

Standards

A

API 2540
ASTM D1250
ASTM D1655
ASTM D2161
ASTM D2270
ASTM D2501
ASTM D2502
ASTM D2880
ASTM D396
ASTM D4052
ASTM D4054
ASTM D5002
ASTM D6074
ASTM D6448
ASTM D6823
ASTM D7042
ASTM D7152
ASTM D7566
ASTM D7666
ASTM D7720
ASTM D8046
ASTM D975

C

CPTC SH/T 0604-2000 eqv. ISO 12185

D

DEFSTAN 91-91
DIN 51659-2

E

EN 16896

G

GB T 29617-2013

I

IP 200
IP 365
ISO 12185
ISO 2909
ISO 91

J

JIG AFQRJOS

S

SH T 0870-2013
SN T 3518-2013

Applications

Your choice: Reset all filters X
Industry
Calculation of the Carbon Type Distribution of Oils with SVM™ 4001 and Abbemat

Calculation of the Carbon Type Distribution of Oils with SVM™ 4001 and Abbemat

SVM™ 4001 determines kinematic viscosity and density at two different measuring temperatures simultaneously in one go. Combined with an Abbemat refractometer, fast and automated carbon distribution analysis of oils is performed according to ASTM D3238.

Certify diesel fuels for both kinematic viscosity and density according to ASTM D975

Certify diesel fuels for both kinematic viscosity and density according to ASTM D975

SVM™ 3001 gives you more parameters than any other kinematic viscometer on the market. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity and more.

Determining the right time for an oil change with SVM™ 3001

Determining the right time for an oil change with SVM™ 3001

SVM™ 3001 gives you more parameters than any other kinematic viscometer on the market. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity, viscosity index and more.

Fastest Viscosity Index Determination from the Lowest Sample Volume with SVM™ 4001

Fastest Viscosity Index Determination from the Lowest Sample Volume with SVM™ 4001

SVM™ 4001 determines kinematic viscosity and density at two different measuring temperatures simultaneously with one filling in one measuring cycle. This innovative double cell technology allows for up to 24 viscosity index measurements per hour.

SVM™ 3001 with Abbemat for Transformer Oils

SVM™ 3001 with Abbemat for Transformer Oils

SVM™ 3001 in combination with Abbemat measures kinematic viscosity, density, dynamic viscosity and the refractive index in one single measuring cycle. It makes measurements of transformer oils routine and easy.

Testing the quality of jet fuel with SVM™ 3001

Testing the quality of jet fuel with SVM™ 3001

When it comes to passengers' safety, rely on SVM™ 3001. SVM™ 3001 gives you more parameters than any other kinematic viscometer on the market. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity and more

Viscosity of Lubricating Oil with SVM™ 3001

Viscosity of Lubricating Oil with SVM™ 3001

SVM™ 3001 gives you more parameters than any other kinematic viscometer on the market. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity, viscosity index and more.

Accessories

Your choice: Reset all filters X
Industry
Industry Group
Standards
Showing to of

Similar products