Microwave Digestion Platform:
Multiwave 5000
- A single microwave digestion platform for all your needs
- >500 pre-installed programs, guiding features, and a 'clever' door
- Up to 64 samples in a single run; tool-free vessel handling; 2x faster vessel opening/closing
- 10,1" high-resolution, durable touchscreen display
40 years’ sample preparation expertise driving the most ambitious, user-friendly microwave digestion system ever built: Digestion of a broad array of samples (varying in difficulty or volume), acid leaching, solvent extraction, evaporation, microwave-induced O₂ combustion, sample drying and synthesis. A comprehensive, interactive method library. A customizable, intuitive user interface, and modern sensor technology, together with Anton Paar’s easy-to-handle compact rotors. 500 pre-installed programs. A very ‘clever’ door. Multiwave 5000. The lab chemist’s dream.
Benefits
- More than 500 programs
- Full-text database search
- Add your own methods if needed
Challenge
Sometimes, it can be difficult to predict which conditions are required for full digestion, or how a sample will react – especially when dealing with unknown or frequently changing samples.
Solution
With a database of more than 500 methods, Multiwave 5000 eases your workload. Use sample tags to search for your application and Multiwave 5000 will provide you with the program – and even recommend a recipe – directly on the instrument, without any paperwork.
Benefit
A pre-installed method library of >500 programs gives you access to the most comprehensive application knowledge base on the market. No need to spend hours of valuable lab time developing the right method.
![SmartScreen SmartScreen](https://www.anton-paar.com/fileadmin/_processed_/7/b/csm_01_Start_from_Home_Screen_d412a84c05.jpg)
- Shortcuts to often-used programs and features
- Start your experiment right from the SmartScreen
Challenge
Conventional user interfaces make you go through pages and pages of menus and lists each time you’re in front of the instrument.
Solution
SmartScreen lets you configure the home screen according to your needs: define shortcuts to often-used programs, menu links, or experiment data.
Benefit
Save time, nerves and money by configuring the Multiwave 5000 home screen, so the instrument behaves like it’s truly yours.
![Video manuals Video manuals](https://www.anton-paar.com/fileadmin/_processed_/c/b/csm_02-Open-Video-Manual_01_c4adaba9fc.jpg)
- Extensive video library with in-depth explanations
Challenge
You’re not an expert in analytical chemistry but you have to perform acid digestion procedures in your lab. You need an instrument that is easy to operate.
Solution
Questions? Simply watch the video manual directly on the screen.
Benefit
We guide you through the whole process step-by-step.
![Hands-free door opener Hands-free door opener](https://www.anton-paar.com/fileadmin/_processed_/3/4/csm_03_Open_Door__747760a020.jpg)
- A 'clever' door indeed
Challenge
You’re standing in front of the instrument with a fully loaded rotor, and the door is closed.
Solution
With the unique hands-free door opener, all you need to do is push gently against the door. You can do it with your elbow – no need to set the vessels or rotor aside.
Benefit
It's the simple things: Multiwave 5000 takes convenience to the next level.
![All kinds of samples All kinds of samples](https://www.anton-paar.com/fileadmin/_processed_/b/4/csm_04_Overview_Samples_4e5598b958.jpg)
- SmartVent technology: Safe overpressure release – for higher sample amounts, higher temperatures and various samples in one run
- Ingenious sensor technology for the best reaction control
Challenge
Some samples are challenging, they have changing compositions, or their reactivity is unknown.
Solution
Multiwave 5000 and its various rotors are designed for any challenge. Premium operation parameters and a supreme reaction control – with the seal of Austrian quality – allow for complete digestion of even the most demanding samples.
Benefit
Our rotors, especially those with SmartVent technology, are designed for a broad range of samples – from routine ones like food, feed, or environmental samples, to demanding ones like ceramics, oil, polymers, and petroleum.
![Future-proof Future-proof](https://www.anton-paar.com/fileadmin/_processed_/8/6/csm_05-Overview-Applications_01_7c3f158313.jpg)
- Acid digestion and leaching
- Solvent extraction and synthesis
- Special solutions: Microwave-induced O2 combustion etc.
Challenge
Some samples require special treatment beyond microwave acid digestion.
Solution
Multiwave 5000 goes beyond digestion: perform other sample preparation techniques or even synthesis. Microwave heating technology makes all these methods faster, safer, cleaner, and more cost-efficient than classic, conventionally-heated alternatives.
Benefit
Multiwave 5000 is a future-proof instrument. With the broadest portfolio available, you can extend your setup – rotors from previous models can be carried over.
![SmartVent technology SmartVent technology](https://www.anton-paar.com/fileadmin/_processed_/b/9/csm_06_Rendering_Mechanism_bd29a0357b.jpg)
- Digestion of a large variety of samples
- Up to 50 % higher sample quantities
- Samples with varying reactivity in a single run
Challenge
Final digestion temperature and sample weight are often limited by the pressure built up during the digestion reaction.
Solution
The use of SmartVent technology is a reliable way to deal with overpressure.
Benefit
Thanks to the controlled release of reaction gases, maximum digestion temperatures are attained independent of the applied sample amounts.
![Intelligent vessels Intelligent vessels](https://www.anton-paar.com/fileadmin/_processed_/5/d/csm_07_HVT-SVT_Vessel_b83f8d1465.jpg)
- SmartVent technology for reliable release of overpressure
- Cooling fins and guided airflow enable fast cooling
- Varying vessel volumes; compact, easy-to-handle vessel design
Challenge
Long liners, lots of vessel components, difficult cleaning and unsafe operation of conventional vessels are downsides in the lab.
Solution
The practical design of the SmartVent vessels – available in different volumes – facilitates all steps of operation: from sample weighing and reagent addition to closing, opening, and cleaning.
Benefit
Fast, safe, tool-free operation providing new levels of performance and convenience for the sample preparation lab.
![Tool-free vessel handling Tool-free vessel handling](https://www.anton-paar.com/fileadmin/_processed_/1/4/csm_08_Setup_SVT_Vessel_de55ac1f79.jpg)
- Tool-free assembly
- HVT and SVT: Only three vessel parts
- Optimized surface and compact design for less adsorption and easier cleaning
Challenge
Setup, but also alignment and cleaning of vessel parts, can be tedious. Tools get lost in the lab and additional handling steps can mean setting up an experiment takes longer than the experiment itself.
Solution
Opening and sealing Multiwave 5000's rotors, vessels, and sensors is quick and simple – just use your hands.
Benefit
Unique tool-free handling makes closing and opening vessels twice as fast.
![Super-high throughput Super-high throughput](https://www.anton-paar.com/fileadmin/_processed_/4/7/csm_09_41HVT56_Rotor_20SVT50_e11c305764.jpg)
- Rotor 41HVT56: highest throughput for routine samples
- Rotor 20SVT50: high-performance rotor with the highest throughput on the market
- Up to 64 samples in disposable glass vials
Challenge
Super-high throughput and fast turnover times are often requirements in elemental analysis.
Solution
Anton Paar’s rotors are robust, lightweight, and accommodate more samples on a smaller footprint.
Benefit
The practical design of our vessel impacts all operation steps: from sample weighing and reagent addition, to closing, opening, and cleaning. Digest up to 64 samples in a single run.
![Safety features Safety features](https://www.anton-paar.com/fileadmin/_processed_/7/3/csm_10_Door_can_not_be_opened_9431272494.jpg)
- Each instrument is tested individually
- Active and passive safety features
- ETL and GS certificates
Challenge
Safety is non-negotiable, especially at elevated temperatures and pressures.
Solution
Multiwave 5000 comes with active and passive safety features: self-checks, software interlocks, and a resealing safety door. This way, users and equipment are protected.
Benefit
Each instrument is tested individually, but beyond that, Multiwave 5000 is the only sample preparation microwave platform with ETL and GS “approved safety” certificates from independent testing institutes.
![Sensor technology Sensor technology](https://www.anton-paar.com/fileadmin/_processed_/3/e/csm_11_Sensor_Technology_592f45e92d.jpg)
- SmartTemp: Contactless internal temp. measurement (SVT/HVT)
- SmartVent detection for registration of venting events
Challenge
Correct temperature and pressure control are the key to reliable results. Conventional sensors require extensive efforts to set up, employ only one control strategy, or react slowly due to infrequent vessel control or temperature measurement solely in a reference vessel.
Solution
Comprehensive reaction control is guaranteed thanks to temperature and pressure control for each position, including various control strategies for the simultaneous digestion of different sample types. Our newest additions: SmartTemp temperature sensor and SmartVent detection (for identification of venting events).
Benefit
Reaction control is easier and safer than ever before: The new SmartTemp sensor combines the fast temperature feedback of an internal temperature probe with the convenience of an infrared sensor.
![Connectivity Connectivity](https://www.anton-paar.com/fileadmin/_processed_/3/a/csm_12_Operator_looking_at_Smartphone_be96704017.jpg)
- Visualization of the instrument's status
- Connect your Multiwave 5000 to the technology of your choice
Challenge
Work interruptions can be annoying and time-consuming. Especially if you have to change rooms to check if everything is running smoothly, or if the experiment has finished.
Solution
The color and mode of SmartLight reflect whether an experiment is in progress, finished, or on standby. SmartLink connects Multiwave 5000 to your PC, notebook, tablet, or mobile phone, so you can monitor and operate experiments remotely.
Benefit
No need to dash over from your desk to check if the run is finished – just cast a glance from afar. Automated notifications keep you informed, whether you’re in the lab or on the go.
Technical specifications
The main acid digestion rotors of Multiwave 5000:*
Rotor 24HVT | Rotor 41HVT | Rotor 20SVT | Rotor 8 NXF/NXQ | Rotor 64MG5 | |
---|---|---|---|---|---|
Number of vessels | 24 | 41 | 20 | 8 | 64 |
Volume | 50 mL/80 mL | 56 mL | 50 mL | 100 mL/80 mL | 5 mL |
Material | PTFE-TFM | PTFE-TFM | PTFE-TFM | PTFE-TFM / Quartz | Glass |
HF resistance | Yes | Yes | Yes | Yes (NXF) | No |
Temperature control | Internal T in all positions / SmartTemp | SmartTemp | T in all positions | IR in 16 positions | |
Pressure control | SmartVent technology / SmartVent detection | p in all vessels | PTFE seal | ||
Applications | Routine samples: Biological and environmental samples, EPA procedures, food, cosmetic and pharmaceutical samples | Harder to digest samples: including polymers, ceramics, petroleum products, and alloys | Most difficult samples | Micro samples up to 20 mg |
*Multiwave 5000 can be used with the digestion rotors (Rotor 16MF100 and 16HF100) of Multiwave PRO as well
Standards
ASTM
Chinese Pharmacopoeia (ChP)
EN
EN ISO
EPA
GA
GB
HJ
ICH
JIS
Japanese Pharmacopoeia (JP)
Pharmacopoeia Europe (Ph. Eur.)
U.S. Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Acid Digestion of Chromium Ores for Analysis with ICP Application Reports
-
Application Collection | Multiwave 5000 Application Reports
-
Application Guide Acid Digestion for Multiwave 5000 Application Reports
-
Closed-vessel Digestion of Cosmetics Application Reports
-
Defined Evaporation in HVT Vessels Application Reports
-
Digestion Using Rotor 24HVT50 for subsequent Element Analysis with ICP Application Reports
-
Digestion in Multiwave 5000 Using HF Complexation of Fluorides Application Reports
-
Digestion of Coal and Graphite Samples for Element Analysis with ICP Application Reports
-
Digestion of Dairy Products for the Element Analysis with ICP and AAS Application Reports
-
Digestion of Demanding Samples for Element Analysis with ICP Application Reports
-
Digestion of Minerals for Element Analysis with ICP Application Reports
-
Digestion of Nutraceuticals for Element Analysis with ICP Application Reports
Similar products
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
![](https://www.anton-paar.com/fileadmin/_processed_/8/7/csm_2432_c665434ddc.jpg)
VESSEL JACKET M100 PEEK
![](https://www.anton-paar.com/fileadmin/_processed_/0/8/csm_13801_f048f1539b.jpg)
SCREW CAP SOLV
![](https://www.anton-paar.com/_assets/f2c683566845b6396b5589f8a60965c7/Images/placeholder.jpg)
PRESSURE VESSEL SOLV HF100
![](https://www.anton-paar.com/fileadmin/_processed_/d/6/csm_235216_25523526e0.jpg)
DISPOSABLE INSERT HVT80 (100 PCS)
![](https://www.anton-paar.com/fileadmin/_processed_/6/7/csm_185564_60fccd47da.jpg)
PRESSURE VESSEL SVT50
![](https://www.anton-paar.com/fileadmin/_processed_/c/3/csm_185547_b1be00435f.jpg)
SEAL FOR PRESSURE VESSEL SVT
![](https://www.anton-paar.com/fileadmin/_processed_/1/8/csm_185563_6a46e2a441.jpg)
SCREW CAP SVT (ASSEMBLED)
![](https://www.anton-paar.com/fileadmin/_processed_/4/9/csm_221788_041b5d4f73.jpg)
ROTOR LID FOAM 20SVT (5 PCS)
![](https://www.anton-paar.com/fileadmin/_processed_/8/4/csm_89088_99f41cf86b.jpg)
STIR BAR PTFE
![](https://www.anton-paar.com/fileadmin/_processed_/1/8/csm_4238_fd00f6b3d3.jpg)
DRIVE BEARING
![](https://www.anton-paar.com/fileadmin/_processed_/8/9/csm_4239_0d027f643c.jpg)
DRIVE STAR
![](https://www.anton-paar.com/fileadmin/_processed_/c/0/csm_5711_8b2f5fc925.jpg)
PRESSURE VESSEL HF100
![](https://www.anton-paar.com/fileadmin/_processed_/d/d/csm_7702_43be952992.jpg)
SEAL FOR VESSEL HOLDER
![](https://www.anton-paar.com/fileadmin/_processed_/a/9/csm_8564_7af96e98e0.jpg)
SEAL FORMING DEVICE FOR 8 CAPS
![](https://www.anton-paar.com/fileadmin/_processed_/6/9/csm_10141_55043dc763.jpg)
CENTRE RING
![](https://www.anton-paar.com/fileadmin/_processed_/5/9/csm_11103_0dda63c7cb.jpg)
SYRINGE FILTER
![](https://www.anton-paar.com/fileadmin/_processed_/9/2/csm_13804_3285aca286.jpg)
SAFETY DISK SOLV
![](https://www.anton-paar.com/fileadmin/_processed_/5/b/csm_13871_4938fdef47.jpg)
SCREW PEEK M3X6
![](https://www.anton-paar.com/fileadmin/_processed_/5/b/csm_18553_e53ed804b3.jpg)
SEAL HUSK S
![](https://www.anton-paar.com/fileadmin/_processed_/3/1/csm_13686_232dcb49c9.jpg)
RACK 16
![](https://www.anton-paar.com/fileadmin/_processed_/c/a/csm_22775_927c50e4cf.jpg)
HEATING ELEMENT D = 10, H = 18
![](https://www.anton-paar.com/fileadmin/_processed_/5/3/csm_97161_ee01ed2377.jpg)
SEAL SOLV C
![](https://www.anton-paar.com/fileadmin/_processed_/3/7/csm_102812_3e5917275f.jpg)
IR CAP
![](https://www.anton-paar.com/fileadmin/_processed_/b/d/csm_102871_afb86a1a08.jpg)
MULTIWAVE 3000 FOAM PACKAGE
![](https://www.anton-paar.com/fileadmin/_processed_/9/c/csm_161100_54d6955355.jpg)
PRESSURE VESSEL HVT80
![](https://www.anton-paar.com/fileadmin/_processed_/a/1/csm_173020_8bd568ef4c.jpg)
CAP NXF (ASSEMBLED)
![](https://www.anton-paar.com/fileadmin/_processed_/e/a/csm_176282_20a36d17ed.jpg)
PRESSURE VESSEL HVT 56
![](https://www.anton-paar.com/fileadmin/_processed_/6/3/csm_228188_9eb8974c3f.jpg)
RACK 10SVT
![](https://www.anton-paar.com/fileadmin/_processed_/b/1/csm_235215_d9149935db.jpg)
DISPOSABLE INSERT HVT50/56 (100 PCS.)
![](https://www.anton-paar.com/fileadmin/_processed_/2/8/csm_240310_4f7d79ca5f.jpg)
QUARTZ INSERT SVT50
![](https://www.anton-paar.com/fileadmin/_processed_/5/4/csm_169329_9a9249de3c.jpg)
ROTOR LID FOAM 24HVT (5 PCS)
![](https://www.anton-paar.com/fileadmin/_processed_/e/1/csm_Rotor-12HVT50-01_2fd79d6114.jpg)
Microwave Digestion Rotor:
Rotor 12HVT50
- A rotor for the microwave reaction platform Multiwave 5000
- Acid digestion of up to 12 samples in one run
- SmartVent technology handles higher temperatures, heavier sample weights, and samples with different reaction behaviors in one run
- Ideal for routine samples (e.g., environmental, agricultural, food)
![](https://www.anton-paar.com/fileadmin/_processed_/c/a/csm_194727_94fd3ac0d8.jpg)
WIFI/BLUETOOTH DONGLE
![](https://www.anton-paar.com/fileadmin/_processed_/9/f/csm_Closing_Station_HVT_01_54a4ab4ee7.jpg)
Closing Station HVT
- Ideal for high-throughput laboratories
- Reproducible closing of all HVT vessels
- Easy, self-explanatory operation
![](https://www.anton-paar.com/fileadmin/_processed_/b/e/csm_HVT-Vessel-Insert-01_eb5929ba3d.jpg)
Disposable Glass Vials for Vessels with SmartVent Technology
More info![](https://www.anton-paar.com/fileadmin/_processed_/f/5/csm_Multiwave-5000_EVAP-02_094f326af1.jpg)
Accessory for HVT Rotors:
24EVAP
![](https://www.anton-paar.com/fileadmin/_processed_/5/9/csm_Multiwave-5000-08_a41d895f8f.jpg)
Microwave Digestion Rotor:
20SVT50
- Rotor for Multiwave 5000
- Ideal for the digestion of demanding samples
- Highest sample throughput (20 samples in a run)
- SmartTemp temperature measurement for optimum reaction control
- Only three parts allows tool-free, easy handling of the vessel
![](https://www.anton-paar.com/fileadmin/_processed_/8/5/csm_rotor_stand_ad3d10b9e1.jpg)
Rotor Stand
More info![For the evaporation of reagents and aqueous solutions using Rotor 8EVAP a scrubber accessory is required. It consists of a set of washing bottles with highly efficient gas diffusers, a chemically resistant vacuum pump and a lead-through connecting the outlet of Rotor 8EVAP to the washing bottles. This lead-through can be installed in every Multiwave PRO. For the evaporation of reagents and aqueous solutions using Rotor 8EVAP a scrubber accessory is required. It consists of a set of washing bottles with highly efficient gas diffusers, a chemically resistant vacuum pump and a lead-through connecting the outlet of Rotor 8EVAP to the washing bottles. This lead-through can be installed in every Multiwave PRO.](https://www.anton-paar.com/fileadmin/_processed_/8/1/csm_scrubber_accessory_84dcbbf096.jpg)
Scrubber Accessory
More info![Microwave-induced oxygen combustion is an innovative method for sample preparation for all kinds of combustible solids such as wood, paper, coal, food or polymers. Microwave-induced oxygen combustion is an innovative method for sample preparation for all kinds of combustible solids such as wood, paper, coal, food or polymers.](https://www.anton-paar.com/fileadmin/_processed_/f/2/csm_oxygen_combustion_set_36cda4a895.jpg)
Oxygen Combustion Set
- Accessory for Rotor 8NXQ
- Suitable for all combustible solids
- Modern alternative to steel combustion bombs
- Parallel combustion of up to 8 samples
- No electrical components or ignition wires
![](https://www.anton-paar.com/fileadmin/_processed_/2/f/csm_magnetic-stirrer-device_1935703cb2.jpg)
Magnetic Stirrer Device
- Accessory for microwave reaction systems
- Stirring improves leaching and extraction processes
- Supports acid digestion of floating samples
- Different speeds selectable
- Retrofittable
![](https://www.anton-paar.com/fileadmin/_processed_/6/7/csm_safety-module-solv_a8a9da1c9f.jpg)
Safety Module SOLV
- Accessory for microwave reaction systems
- Ensures safe solvent extraction and microwave-assisted synthesis
- Fail-safe design for maximum safety
- Can be retrofitted to existing setups
![The seal forming device enables the proper pre-forming and safe storage of seals and screw caps of Rotor 8 and 16. One unit has a capacity for 8 caps/seals of different kinds. Storage in this device prolongs the lifetime of the lip-type seals. The seal forming device enables the proper pre-forming and safe storage of seals and screw caps of Rotor 8 and 16. One unit has a capacity for 8 caps/seals of different kinds. Storage in this device prolongs the lifetime of the lip-type seals.](https://www.anton-paar.com/fileadmin/_processed_/3/0/csm_seal_forming_device_60c6e6637c.jpg)
Seal Forming Device
More info![](https://www.anton-paar.com/fileadmin/_processed_/6/6/csm_hydrolysis-set-01_36d0aa4e18.jpg)
Hydrolysis Set
- Protein hydrolysis accessory for microwave reaction systems
- Protein hydrolysis of milligrams to grams
- Samples processed in less than one hour
- For up to 60 samples in one run
- Inert gas can be applied
![The cylindrically shaped passive heating elements are made of sintered silicon carbide (SiC). Due to its high microwave absorbance and excellent heat capacity, SiC can be used to efficiently heat low-absorbing solvents (toluene, dioxane, THF…) in a microwave environment. The cylindrically shaped passive heating elements are made of sintered silicon carbide (SiC). Due to its high microwave absorbance and excellent heat capacity, SiC can be used to efficiently heat low-absorbing solvents (toluene, dioxane, THF…) in a microwave environment.](https://www.anton-paar.com/fileadmin/_processed_/c/5/csm_passive_heating_elements_127e01a70e.jpg)
Passive Heating Elements
- Accessory for microwave reaction systems
- Made of sintered silicon carbide (SiC) to provide high microwave absorbance and excellent heat capacity
- Purchase once and reuse again and again
- Chemically inert and easy to clean
![Different racks are available for the adequate storage of the various vessel types and liners of Multiwave PRO as well both vial sizes of Monowave 300. For vessels applicable in the multimode reactors Anton Paar supplies Rack 16, a polyethylene foam block for 16 vessels or liners of Rotor 8 and Rotor 16. Different racks are available for the adequate storage of the various vessel types and liners of Multiwave PRO as well both vial sizes of Monowave 300. For vessels applicable in the multimode reactors Anton Paar supplies Rack 16, a polyethylene foam block for 16 vessels or liners of Rotor 8 and Rotor 16.](https://www.anton-paar.com/fileadmin/_processed_/1/4/csm_racks_79b48e6767.jpg)
Racks
- Different racks for storing vessels, liners, and vials
- For Multiwave 5000: Rack 12 for HVT vessels, Rack 10 for SVT vessels, Rack 16 for 16 vessels or liners of Rotor 8 and Rotor 16
- For Monowave 200/400/450: 24 x 30 mL vials and 40 x 10 mL vials
![Pressure/temperature sensor accessory for precise reaction control within the reference vessel of Rotor 16MF100 and/or Rotor 16HF100. Pressure/temperature sensor accessory for precise reaction control within the reference vessel of Rotor 16MF100 and/or Rotor 16HF100.](https://www.anton-paar.com/fileadmin/_processed_/a/7/csm_p_t_sensor_accessory_8700cc91c4.jpg)
p/T Sensor Accessory
- Accessory for Rotor 16MF100 or Rotor 16HF100
- Precise reaction control within a reference vessel
- Simultaneous pressure and temperature measurement up to 86 bar (1250 psi) and 280 °C
![The pressure sensor accessory allows for precise reaction control within the reference vessel of Rotor 16MF100 or Rotor 16HF100. The pressure data is transferred to the oven via infrared signal. If required, the pressure sensor accessory can be upgraded to a pressure/temperature sensor accessory. The pressure sensor accessory allows for precise reaction control within the reference vessel of Rotor 16MF100 or Rotor 16HF100. The pressure data is transferred to the oven via infrared signal. If required, the pressure sensor accessory can be upgraded to a pressure/temperature sensor accessory.](https://www.anton-paar.com/fileadmin/_processed_/d/3/csm_pressure_sensor_accessory_f7e9a29929.jpg)
Pressure Sensor Accessory
More info