Automatic kinematic viscometer:
SVM
- Conduct viscosity measurement of all samples without changing capillaries
- For kinematic viscosity at any temperature between 15 °C and 100 °C
- Comply with ASTM D396, D975, D3699, D6158, D6823, D7467, and other standards
- Get viscosity index and density according to ASTM D4052
- Choose from a wide portfolio of automated sample changers
Our automatic kinematic viscometers determine kinematic and dynamic viscosity, density, viscosity index (VI), cloud point, freeze point, and many other parameters in one run. Exchange all your capillaries for a single unit. The SVM series covers the entire range with one cell for maximum flexibility. Enjoy all the benefits of ASTM D7042 and report in both D7042 as well as D445 with the integrated ASTM-defined bias corrections. No matter the sample, there’s an SVM that fits your needs.
Key features

Save time with our automatic kinematic viscometers
- 150 % higher throughput compared to manual methods
- Faster results help avoid out-of-spec production
- Temperature equilibration in one minute or less

Experience error-free digital data handling
- Automatic calculations and digital data recording and storage for error-free measurements and traceability
- Data export from device to a PC or USB drive
- One-click data access from your automatic kinematic viscometer
- Compatible with AP Connect for digital data management (for SVM 2001/SVM 3001/ SVM 3001 Cold Properties/SVM 4001)

Improve safety for lab and operator
- A metal measuring cell makes glass breakage a thing of the past
- Built-in Peltier thermostatting for fast temperature control
- Reduced exposure to hazardous solvents or flammable bath liquids

Save costs while lowering your carbon footprint
- Analysis with just 5 mL of sample and 6 mL of solvent
- Low energy consumption – 50 W to get started
- Minimal downtime: 2-minute cleaning, 30-minute downtime during maintenance
- Quality control documentation efforts reduced by 50 %
- No external PC or software needed

Stay compliant and benefit from bias correction
- ASTM D7042 is referenced in ASTM, SAE, ISO, IP, EN, DIN, DEFSTAN, ML, GB, GOST, and other standards as an accepted alternative to D445
- With the ASTM bias correction, you can report results in both D7042 and D445
- Complies with ASTM D396, D975, D1655, D3699, D6158, D6823, D7467, and other standards
- ASTM D4052 density measurement included (SVM 3001/SVM 3001 Cold Properties/SVM 4001)

Enjoy 24/7 automatic kinematic viscometer measurements
- Robotic solution options for labs analyzes hundreds of samples per day
- Compatible with heated and non-heated sample changers for all-day measurements
- Reproducible and unattended filling and cleaning process, even over night
Technical specifications
SVM 1001 | SVM 1001 Simple Fill | SVM 2001 | SVM 3001 | SVM 3001 Cold Properties | SVM 4001 | |
Patents | AT5160588 (B1), US10036695 (B2), CN105424556 | AT5160588 (B1), US10036695 (B2), CN105424556, AT516302 (B1), CN105628550 | ||||
Test methods | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896, ASTM D4052 (optional) | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 ASTM D2386 equivalent or better ASTM D2500 equivalent or better | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 | |
Measuring Range | ||||||
Viscosity | 0.3 mm²/s to 5,000 mm²/s | 0.2 mm²/s to 30,000 mm²/s | ||||
Density | --- | 0 g/cm³ to 3 g/cm³ | ||||
Temperature | 15 °C to 100 °C (59 °F to 212 °F) (one temperature as standard, second temperature optional) | 15 °C to 100 °C (59 °F to 212 °F) | -60 °C to +135 °C (-76 °F to +275 °F) | -60 °C to +100 °C (-76 °F to +212 °F) | 15 °C to 100°C (59 °F to 212 °F) | |
Precision | ||||||
Viscosity repeatability* | 0.1 % | |||||
Viscosity reproducibility* | 0.35 % | |||||
Density repeatability* | --- | 0.0002 g/cm³ (0.00005 g/cm³ with ASTM D4052 option) | 0.00005 g/cm³ | |||
Density reproducibility* | --- | 0.0005 g/cm³ (0.0001 g/cm³ with ASTM D4052 option) | 0.0001 g/cm³ | |||
Cloud/freeze point repeatability* | --- | <0.5 °C / <0.5 °C | --- | |||
Cloud/freeze point reproducibility* | --- | <2.5 °C / <1.3 °C | --- | |||
Temperature repeatability | 0.005 °C (0.009 °F) | |||||
Temperature reproducibility | 0.03 °C (0.054 °F) from 15 °C to 100 °C | 0.03 °C (0.054 °F) from 15 °C to 100 °C 0.05 °C (0.09 °F) outside this range | 0.03 °C (0.054 °F) from 15 °C to 100 °C | |||
Performance | ||||||
Sample voume min. / typical | 1.5 mL / 5 mL | 3.5 mL / 8 mL | 1.5 mL / 5 mL | 2.5 mL / 6 mL | ||
Solvent voume min. / typical | 1.5 mL / 6 mL | 5 mL / 10 mL | 1.5 mL / 6 mL | 2.5 mL / 10 mL | ||
Max. sample throughput | 37 samples per hour | 21 samples per hour | 33 samples per hour | 30 samples per hour | 24 samples per hour | |
Features | ||||||
Optional upgrades | Second temperature | Automatic VI determination ASTM D4052-compliant density measurement | Chemical upgrade kit Modularity with Abbemat refractometers 300/500, 350/550, 450/650 | Modularity with Abbemat refractometers 300/500, 350/550, 450/650 | ||
Accessories | Magnetic particle trap (MPT) | None | Magnetic particle trap (MPT) Hot filling attachment (HFA) | Magnetic particle trap (MPT) | ||
Automation | None | Integrated Simple Fill Filling Device | Optional Autosampler (Xsample 340, 520, 530, 610, 630) + High-Throughput Platform HTV | Optional Autosampler (Xsample 340, Xsample 530) + High-Throughput Platform HTV | Optional Autosampler (Xsample 340, 530, 610, 630) + High-Throughput Platform HTV | |
Technical Data | ||||||
Data memory | 1,000 measurement results | |||||
HID (Human Interface Device) | 7" touchscreen | 10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader | ||||
Interfaces | 4 x USB (3 x A, 1 x B) | 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 X CAN bus, 1 x RS-232, 1 x VGA | ||||
Compliance | CE mark; EMC directive EN 61326-1; LV directive EN 61010-1; RoHS | |||||
Power supply | At instrument: DC, 24 V /3A, AC adapter 90 VAC to 264 VAC, 47 Hat to 63 Hz, < 75W | AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max. | ||||
Ambient conditions | 15 °C to 35 °C (59 °F to 95 °F), max. 80 % r.h. non-condensing | |||||
Net weight in kg (in lbs) | 5.6 kg (12.3 lbs) | 6.6 kg (14.6 lbs) | 15.9 kg (35.1 lbs) | 17.6 kg (38.8 lbs) | 18.0 kg (39.7 lbs) | 17.8 kg (39.2 lbs) |
Dimensions (W x D x H) | 26.5 cm x 36.5 cm x 18 cm (10.4 in x 14.4 in x 7.1 in) | 33 cm x 36.5 cm x 20.5 cm (13 in x 14.4 in x 8.1 in) | 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) |
*Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standards.
Standards
ABNT
ANP
API
ASTM
CAN/CGSB
CPTC
DEFSTAN
DIN
EN
GB
GJB
GOST
IP
IS
ISO
JIG
MIL
OENORM
RANP
SAE
SH
SN
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Automated Viscosity Measurement of In-Service Oils Application Reports
-
Automotive | SVM 3001: Automotive Brake Fluids Application Reports
-
Aviation | Cold Flow Properties of Jet Fuel (Freezing Point) Application Reports
-
Aviation | Jet Fuel Viscosity - SVM 3001 Application Report Application Reports
-
Aviation | Viscosity of Aviation Lube Oils and Hydraulic Fluids Application Reports
-
Base Oils, Lubricants | SVM 1001 for Quality Control of Base Oils Application Reports
-
Base Oils, Pharma, Lubricants | Viscosity of White Oils Application Reports
-
Base and Lube Oils | Viscosity Index of Base and Lube Oils with SVM 4001 Application Reports
-
Food | Liquid Food Flavors with SVM 3001 and Abbemat Refractometer Application Reports
-
Food, Bio-fuel | Kinematic Viscosity of Edible Oils Application Reports
-
Fuels | SVM 1001 for Measuring Kinematic Viscosity of Diesel and Biodiesel Fuels Application Reports
-
Fuels | Verifying ISO 8217 Specifications for Marine Fuel Oils with SVM 3001 Application Reports
-
Fuels | Viscosity Measurement of Diesel Fuel - SVM 3001 Application Report Application Reports
-
Hydraulics | Kinematic Viscosity of Hydraulic Fluids Application Reports
-
Hydraulics | SVM for Viscosity Determination of Hydraulic Fluid Application Reports
-
Lubricants | SVM 1001 for Fast and Easy Quality Control of Engine Oils Application Reports
-
Lubricants | SVM 1001 for Kinematic Viscosity Measurement of In-Service Oils Application Reports
Similar products
Consumables, Accessories, Software & Reference materials
Consumables, Accessories, Software & Reference materials
Accessories & Software
Accessories & Software
To find out if you can purchase online from your location, check the online availability below.
If you do not find the item you require, please contact your Anton Paar sales representative.

O-RING 3x1 KALREZ 6375 SPECTRUM
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

"ADAPTER LUER LOCK 1/4""-28 UNF PEEK"
SVM 1001

HOSE 3.2x6.4 mm TYGON A-60-G, BLACK (FORMERLY:
NORPRENE A-60-G)
SVM 2001 | 3001 | 3001 Cold Properties | 4001

HOSE 380x3x2 FEP 2x1/4"-28 UNF
SVM 4001

ANGULAR SCREWDRIVER TORX T10
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

CABLE TIE HEAT-RESISTANT 100 pcs
SVM 1001

SYRINGES 5 ml LUER (100 pcs.)
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

PROTECTIVE COVER DMA 501/1001 W. XS200
SVM 1001

ANGULAR SCREWDRIVER TORX T20
SVM 2001 | 3001 | 3001 Cold Properties | 4001

SYRINGES 10 ml LUER (100 pcs.)
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

HOSE 250x3x2 FEP 2x1/4"-28 UNF "BB"
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

PROTECTIVE COVER DMA 501/1001 W. XS200HR
SVM 1001

HOSE CLAMP DMIN 8.8 DMAX 9.3
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N100 100 ml - 280 / 86 / 9.7 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
280 / 86 / 9.7 mPa.s

VISCOSITY STANDARD ANTON PAAR N100 500 ml - 280 / 86 / 9.7 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

HOSE 5x8 VITON-BK ISO VERSINIC
SVM 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD APCL68 CCS (500 mL)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Low-temperature viscosity standard.
- Viscosity values from 19,584 mPa.s (-15 °C) up to 11,417 mPa.s (-10 °C)

VISCOSITY STANDARD ANTON PAAR N4000 500 ml - 16000 / 2900 / 100 mPa.s
SVM 1001 | 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N14 500 ml - 25 / 12 / 2.7 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

SYRINGES 2 ml LUER (100 pcs.)
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD APCL60 CCS (500 mL)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Low-temperature viscosity standard.
- Viscosity values from 21,961 mPa.s (-18 °C) up to 5,731 mPa.s (-5 °C)

VISCOSITY STANDARD SET FOR SVM 1001 4x100 ml AP S3, N7.5, N26, N415
SVM 1001 | 1001 Simple Fill

VISCOSITY STANDARD ANTON PAAR N1400 100 ml - 5000 / 1200 / 74 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

ADAPTER LUER CONE
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N1400 500 ml - 5000 / 1200 / 74 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

MALE LUER PLUG
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N26 (C) 100 ml - 50 / 21 / 4.2 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N26 (C) 500 ml - 50 / 21 / 4.2 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

ACCESSORY KIT SVM 1001
SVM 1001 | 1001 Simple Fill

VISCOSITY STANDARD ANTON PAAR N415 (H) 100 ml - 1100 / 330 / 32 mPa.sc
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Recommended for DIN/SSA/UL spindles

SET BATTERY HOLDER SVM 1001
SVM 1001 | 1001 Simple Fill

HOSE 4X6 SILICONE
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N415 (H) 500 ml - 1100 / 330 / 32 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

SYRINGE HOLDER
SVM 1001 | 1001 Simple Fill

PRINTER PAPER 57x30 STANDARD
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 100 ml - 10 / 5.4 / 1.6 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 500 ml - 10 / 5.4 / 1.6 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

PRINTER CONNECTION CABLE
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N75 500 ml - 164 / 61 / 8.8 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

ADAPTER LUER 1/4" UNF
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR S3 (L) 500 ml - 3.7 / 2.3 / 0.9 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

PRINTER PAPER FOR EPSON TM-U220
SVM 2001 | 3001 | 3001 Cold Properties | 4001

RIBBON CARTRIDGE FOR EPSON PRINTER TM-U220
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR S6 500 ml - 8.8 / 4.7 / 1.5 mPa.s
SVM 1001 | 1001 Simple Fill | 2001 | 3001 | 3001 Cold Properties | 4001

BRUSH 175x25x2.7 NYLON 0.06 (5 pcs.)
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD APCL38 CCS (500 mL)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Low-temperature viscosity standard.
- Viscosity values from 20,950 mPa.s (-25 °C) up to 2,670 mPa.s (-5 °C)

HOSE CLAMP DMIN 5.8 DMAX 6.5
SVM 2001 | 3001 | 3001 Cold Properties | 4001

HOSE 3.2x6.4 mm TYGON CHEMICAL (FORMERLY:
NORPRENE CHEMICAL)
SVM 2001 | 3001 | 3001 Cold Properties | 4001

VISCOSITY STANDARD ANTON PAAR N2B 100 ml - 7.6 / 3.9 mPa.s at -20 / 0 °C
SVM 2001 | 3001 | 3001 Cold Properties | 4001

CARRYING CASE SVM 1001
SVM 1001 | 1001 Simple Fill

ISO 17034-certified reference material:
Density standards
SVM 2001 | 3001 | 4001
- Market-leading uncertainty of 0.015 kg/m³ (ISO 17034)
- Application-specific density standards, available via webshop
- Online certificate with lifetime reference values guarantee
- Conformity with ISO requirements ISO 17025 and even ISO 17034
- Safety glass ampoule for zero contamination

MAGNETIC PARTICLE TRAP SVM 1001 ONLY FOR SVM 1001 – NOT FOR Simple Fill
SVM 1001

Heated sample changer:
Xsample 610
SVM 2001 | 3001 | 4001
- The single sample changer for heavy duty applications
- Heats up samples up to 95 °C (200 °F) for easy filling
- Ideal for crude oil, waxes, and gels
- Automated cleaning and drying enables minimal operator handling
- Compatible with most commercially available syringes

Heated sample changer:
Xsample 630
SVM 2001 | 3001 | 4001
- The multi-sample changer with no limits for high viscosities
- Handles up to 56 samples with heated (up to 95 °C / 200 °F) and non-heated samples at the same time
- Automated cleaning and drying
- Safe electrical heating, no water bath required

Accessory for used-oil analysis:
Magnetic particle trap (MPT)
SVM 2001 | 3001 | 3001 Cold Properties | 4001


Sample changer:
Xsample 340
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- The single sample changer for different syringe sizes
- The robust solution for reliable and repeatable results
- Prevents sample carry-over with automatic rinsing and drying after each sample
- Highly resistant wetted parts for handling aggressive samples

Sample changer:
Xsample 530
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- The multi-sample changer with the highest cleaning performance
- Handles up to 71 samples with optional sample recovery
- Automated cleaning and drying with up to three solvents
- Customized magazines available for your own vials
- Measurement of volatile samples

DRYING CARTRIDGE
SVM 2001 | 3001 | 3001 Cold Properties | 4001

KEYBOARD USA USB
SVM 2001 | 3001 | 3001 Cold Properties | 4001

KEYBOARD GERMAN USB
SVM 2001 | 3001 | 3001 Cold Properties | 4001

STAND FOR Xsample
SVM 2001 | 3001 | 3001 Cold Properties | 4001

SAFETY WASTE CONTAINER
SVM 2001 | 3001 | 3001 Cold Properties | 4001

PRINTER EPSON TM-U220D or B
SVM 2001 | 3001 | 3001 Cold Properties | 4001

ETHERNET CABLE FOR PC CONNECTION CAT5E, RJ45G-RJ45G, SFTP, 2 m, CROSSED
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Only for ViscoQC 300. Cable for LIMS Bridge connection to PC for transferring measurement data.

BARCODE SCANNER 2D WITH USB CABLE
SVM 2001 | 3001 | 3001 Cold Properties | 4001
Only for ViscoQC 300

PROTECTING COVER FOR KEYBOARD
SVM 2001 | 3001 | 3001 Cold Properties | 4001

RIBBON CARTRIDGE FOR CITIZEN PRINTER CBM910 / IDP3110
SVM 2001 | 3001 | 3001 Cold Properties | 4001

Sample changer:
Xsample 520
SVM 2001 | 3001 | 4001
- The multi-sample changer that provides first-class filling at a snap
- Handles up to 96 samples in one magazine
- Ideal for beer, wine, soft drinks, syrups, and other aqueous samples which can be replaced without intermediate cleaning
- Multiple fillings from the same vial if required

Gesture Control
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Equips your density (and sound velocity) meter or viscometer for gesture-controlled operation
- Interact with your device without touching it, e.g. when your hands are dirty or wet
- Start and stop measurements, select methods, etc.

SVM 1001 Dual Temperature Option
SVM 1001 | 1001 Simple Fill

Lab execution software:
AP Connect Start
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Now: 100 % discount at checkout!
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule

Lab execution software:
AP Connect Standard (subscription license)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Standard (one-time license fee)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Pharma (subscription license)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Pharma (one-time license fee)
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

AP DENSITY STANDARD DODECANE 1x10 mL WITH ISO 17034 CERTIFICATE
SVM 2001 | 3001 | 4001
- Density standard with low density (750 kg/m³)
- Organic liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD OIL 30 cSt @ 40 °C 1x10 mL, WITH ISO 17034 CERTIFICATE
SVM 2001 | 3001 | 4001
- Density standard with low density (830 kg/m3)
- Organic liquid
- Viscous liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements