Rotational viscometer:
ViscoQC
- Multi-point measurements on 7” color touchscreen
- Viscosity range from 3 mPa.s to 40,000,000 mPa.s
- 6 RH spindles to measure medium-viscosity samples (paints, dairy products, and many more)
Do you need an easy-to-use viscometer that provides convenient operation for the most reliable and traceable viscosity results in your day-to-day work? ViscoQC rotational viscometers ensure the quality of your substance – from liquid to semi-solid. Eliminate the risk of measurement errors and free up your time and budget with the simplest spindle exchange mechanism, automatic spindle detection, automatic speed searching function for new formulations, and more. All of these brilliant features have been developed to make your life easier. Your existing SOPs can be easily converted if the same setup and settings are used.
It’s time to switch to an easier way. It’s time to switch to ViscoQC.
Key features

Unpack your digital viscometer – and measure right away
Setup takes less than two minutes: ViscoQC comes preassembled, and includes an SOP booklet with first steps and straightforward user training. Built-in digital leveling automatically monitors and indicates the correct leveling status, which prevents faulty measurements and ensures superb, full-scale-range accuracy of +- 1 %. For pharmaceutical customers, Anton Paar offers instrument qualification packages: ViscoQC is qualified and ready to use within a single day – compliant to 21 CFR Part 11, GMP, and GAMP 5 (ViscoQC 300 + V-Comply), or to GMP and GAMP 5 (ViscoQC 100).

The easiest way to measure dynamic viscosity
You don’t need to be an expert to measure with ViscoQC. Anton Paar’s viscometers guide you from start-up through the entire measurement process via an intuitive user interface. Continue to use the standard operating procedure methods of your existing rotational viscometer: ViscoQC uses the same instrument setup and measuring settings to deliver the same results. Each spindle is equipped with magnetic coupling for easy spindle exchange, saving you up to 15 seconds per test. The coupling also reduces maintenance costs by protecting the spindle and instrument against damage caused by knocks or bending. All spindles from Anton Paar are made of chemically resistant stainless steel (AISI 316L), which increases spindle lifetime by protecting them from corrosion.

Full traceability for reliable viscosity tests
ViscoQC instantly detects and documents the measuring setup of the following parts:
- Spindles by Toolmaster™ and spindle guard by TruGuard™
- Temperature devices and sensors (PTD 80, PTD 175, Pt100)
- Heli-Plus motorized accessory
- PTD 100 Cone-Plate accessory
To ensure correct viscosity results, all spindle data is automatically delivered to the viscometer as soon as the spindle is attached. With ViscoQC 300, Toolmaster™ further restricts each method to a unique spindle identity. No time is wasted with repeat measurements (e.g., if the wrong spindle is mistakenly chosen from the spindle list). If you need to measure new formulations, ViscoQC automatically leads you to the right spindle/speed configuration using TruMode™.

The most convenient way to generate and export viscosity quality control data
Every ViscoQC includes the V-Collect PC data collection software free of charge. As ViscoQC 100 does not store any data, results are directly exported to V-Collect or printed via the Dymo® LabelWriter™ after each test. ViscoQC 300 has a huge data memory for up to 999 measurements with up to 10,000 sub-measurements on 150 MB. Additionally it is possible to print and export data as PDF, CSV, or page printer (USB or network) to V-Collect and the Dymo® LabelWriter™. For automated data export, ViscoQC 300 can be integrated into your network via Laboratory Information Management System (LIMS) or FTP Server.

Your future-proof rotational viscometer
ViscoQC 100 and ViscoQC 300 are future-proof: They grow with your evolving needs. To measure new paste-like formulations (e.g., wall putty), you can upgrade your instruments with the Heli-Plus and T-bar spindles. Gel time/pot life determination of adhesives is automatically possible with both models. If you need super-fast and accurate sample temperature control (max. heating/cooling rate 5.2/6.3 K/min) and have less than 20 mL of sample volume, simply use the Peltier temperature device PTD 80. For very small sample volumes (0.5 mL to 2 mL), PTD 100 Cone-Plate is the accessory of choice. Further software functionality can be added to ViscoQC 300 with up to two optionally upgradeable software modules: V-Curve and/or V-Comply.
- V-Curve adds real-time graphs, analysis (e.g., yield point), programmability, and extended method functionality (e.g., with PTD 175)
- V-Comply delivers compliance to 21 CFR Part 11 (e.g., audit trail, electronic signature), including qualification documentation
For automated sample name input, a bar code reader is available for ViscoQC 300.

Three-year warranty and on-site service for maximum uptime
ViscoQC comes with a unique three-year warranty. With 86 locations and 350 certified service engineers, we guarantee a response within 24 hours. Maintenance of ViscoQC and other Anton Paar products can be performed in a single appointment, so you don’t need to contact different suppliers or send in your viscometer for service or repair. As ViscoQC uses highly durable bearings and regularly performs an automatic bearing check (TruSine™), your uptime is maximized and ongoing service costs are reduced to a minimum.
Technical specifications
ViscoQC 100 | ViscoQC 300 | |||||
---|---|---|---|---|---|---|
L | R | H | L | R | H | |
Viscosity test | Single-point | Multi-point | ||||
Viscosity range [mPa.s or cP] (depends on measuring system) | 0.2* to 6 M | 1.6** to 40 M | 13.2*** to 320 M | 0.1* to 6 M | 1.3** to 40 M | 10.6*** to 320 M |
Speed [rpm] | 0.1 rpm to 200 rpm 740 increments | 0.01 rpm to 250 rpm Speed list with 18 standard speeds Freely selectable speeds within the speed range | ||||
Max. spring torque [mNm] | 0.0673 | 0.7187 | 5.7496 | 0.0673 | 0.7187 | 5.7496 |
Accuracy | ±1.0 % full scale range | |||||
Repeatability | ±0.2 % | |||||
Heli-Plus compatibility | ✔ | |||||
PTD 100 Cone-Plate compatibility | ✔ | |||||
Peltier temperature control | 15 °C to 80 °C 0 °C to + 100 °C | 15 °C to 80 °C 0 °C to + 100 °C | ||||
Liquid temperature control/sensing | Ambient to +100 °C (control of L/RH spindles with optional thermostat bath) | |||||
Temperature sensing | -60 °C to +300 °C (temperature sensing with optional Pt100) | |||||
Intuitive user interface | 3.5" color LCD display | 7" color touchscreen display; Options: keyboard, mouse, 2D bar code reader | ||||
Languages | EN, DE, ES, FR, CN, JA, KO, IT, RU, PT | EN, DE, ES, FR, IT, PT, JA, KO, RU, ZH-CN, ZH-TW, PO, CZE | ||||
Built-in digital leveling | ✔ | |||||
Easiest spindle exchange (magnetic coupling) | ✔ | |||||
Automatic spindle recognition (Toolmaster™) | ✔ | |||||
Automatic measuring range calculation | ✔ | |||||
Automatic speed searching function (TruMode™) | ✔ | |||||
Spindle correction by user | ✔ | |||||
Users, user groups | None | ✔ Customizable |
* With optional PTD 100 Cone-Plate, with L1 spindle 15 mPa.s
** With optional PTD 100 Cone-Plate, with RH1 spindle 100 mPa.s
*** With optional PTD 100 Cone-Plate, with RH1 spindle 800 mPa.s
M = million
DIN = Concentric cylinders, double-gap
SSA = Small sample adapter (SC4-xx)
UL = Ultra-low viscosity adapter
Standards
ASTM
BS
Chinese Pharmacopoeia (ChP)
DIN
EN
ISO
Japanese Pharmacopoeia (JP)
Pharmacopoeia Europe (Ph. Eur.)
TAPPI
U.S. Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Adhesives | Measurement of Hot Melt Adhesives According to ASTM D3236 Application Reports
-
Adhesives | ViscoQC Quality Control of Adhesives Application Reports
-
Beverages | ViscoQC Quality Control of Fruit Juice Application Reports
-
Chemicals | Rotational Viscosity Testing in Battery Cell Manufacturing Application Reports
-
Chemicals | Rotational Viscosity Testing of Isocyanates with ViscoQC Application Reports
-
Coatings, Paints | ViscoQC Quality Control of Coatings and Paints Application Reports
-
Cosmetics | Rotational Viscosity Testing of Make-up (Remover) with ViscoQC Application Reports
-
Cosmetics, Pharma | Rotational Viscosity Testing of Hand Sanitizer with Visco Application Reports
-
Detergents | ViscoQC Quality Control of Dishwashing Detergents Application Reports
-
Food | Rotational Viscosity Testing of Chocolate with ViscoQC Application Reports
-
Food | Rotational Viscosity Testing of Dairy Products with ViscoQC Application Reports
-
Food | Rotational Viscosity Testing of Porridge with ViscoQC Application Reports
-
Food | Rotational Viscosity Testing of Sauces and Dressings with ViscoQC Application Reports
-
Food, Beverage | Rotational Viscosity Testing of Gum Arabic with ViscoQC Application Reports
-
Minerals | Viscosity Testing of Bentonite Clay with ViscoQC Application Reports
Similar products
ViscoQC FAQ
A. General
B. Cleaning
C. Maintenance
D. ViscoQC 300 and its software packages
E. Contact
Consumables, Accessories & Software
Consumables, Accessories & Software
Accessories & Software
Accessories & Software
To find out if you can purchase online from your location, check the online availability below.
If you do not find the item you require, please contact your Anton Paar sales representative.

LABELS 90 x 29 mm, 1 x 400 pcs. FOR BROTHER Label Printer
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

ANGULAR SCREWDRIVER TORX T10
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MOUNTING LINK SET
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

ANGULAR SCREWDRIVER TORX T20
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

O-RING 22x3 VMQ 70 SILICONE (RED-BROWN)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- O-ring sitting on the bottom plug of cups of the following DIN/SSA/UL systems.
- Recommended for low- and high-temperature range, especially when working with PTD 175 Peltier temperature device.

VISCOSITY STANDARD APCL68 CCS (500 mL)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 19,584 mPa.s (-15 °C) up to 11,417 mPa.s (-10 °C)

VISCOSITY STANDARD APCL60 CCS (500 mL)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 21,961 mPa.s (-18 °C) up to 5,731 mPa.s (-5 °C)

SILICONE VISCOSITY STANDARD AP RT30k 600 ml - 33 / 30 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- 33 Pa·s / 30 Pa·s at 20 °C / 25 °C
- Recommended for ViscoQC x00 - H

SILICONE VISCOSITY STANDARD AP RT5k 600 ml - 5.6 / 5.0 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- 5.6 Pa·s / 5.0 Pa·s at 20 °C / 25 °C
- Recommended for ViscoQC x00 - R

SILICONE VISCOSITY STANDARD AP RT500 600 ml - 554 / 501 mPa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- "554 mPa·s / 501 mPa·s at 20 °C / 25 °C
- Recommended for ViscoQC x00 - L and ViscoQC x00 - R"

SILICONE VISCOSITY STANDARD AP RT10 600 ml - 11 / 10 mPa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- 11 mPa·s / 10 mPa·s at 20 °C / 25 °C
- Recommended for ViscoQC x00 - L

VISCOSITY STANDARD ANTON PAAR N26 (C) 100 ml - 50 / 21 / 4.2 mPa.s
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 100 ml - 10 / 5.4 / 1.6 mPa.s
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR S3 (L) 100 ml - 3.7 / 2.3 / 0.9 mPa.s
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for DIN/SSA/UL spindles

VISCOSITY STANDARD ANTON PAAR N415 (H) 100 ml - 1100 / 330 / 32 mPa.sc
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for DIN/SSA/UL spindles

LABELS 89 x 28 mm, 2 x 130 pcs. FOR DYMO LabelWriter
ViscoQC 100 L | 100 R | 100 H
For Dymo LabelWriter (ViscoQC 100 only)

LABELS 89 x 36 mm, 2 x 260 pcs. FOR DYMO LabelWriter
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
For Dymo LabelWriter (ViscoQC 100, ViscoQC 300)

SILICONE VISCOSITY STANDARD AP RT50 600 ml - 55 / 50 mPa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
55 mPa·s / 50 mPa·s at 20 °C / 25 °C

SILICONE VISCOSITY STANDARD AP RT100 600 ml - 111 / 100 mPa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
111 mPa·s / 100 mPa·s at 20 °C / 25 °C

SILICONE VISCOSITY ETALON AP RT1k 600 ml - 1.1 / 1.0 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
1.1 Pa·s / 1.0 Pa·s at 20 °C / 25 °C

SILICONE VISCOSITY STANDARD AP RT12k 600 ml - 14 / 13 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
14 Pa·s / 13 Pa·s at 20 °C / 25 °C

SILICONE VISCOSITY STANDARD AP RT60k 600 ml - 66 / 60 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
66 Pa·s / 60 Pa·s at 20 °C / 25 °C

SILICONE VISCOSITY STANDARD AP RT100k 600 ml - 111 / 100 Pa.s at 20 / 25 °C
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
111 Pa·s / 100 Pa·s at 20 °C / 25 °C

FOAM PACKING MATERIAL ViscoQC
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

VITON O-RING FOR DIN/SC4 SYSTEMS
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
O-ring sitting on the bottom plug of cups of the following DIN/SSA systems.

O-RING 22x3 EPDM 70
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
O-ring sitting on the bottom plug of cups of the following DIN/SSA systems.

GLASS ROD
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
10 pcs. of glass rods for Gel Time Kit.

DISPOSABLE MEASURING CUP D22 1 pack = 100 pcs. (blank aluminium)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
For measuring system 4B2 insulated and L1D22.

VISCOSITY STANDARD APCL16 CCS (500 mL)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 10 459 mPa.s (-40°C) up to 1 014 mPa.s (-18°C)

VISCOSITY STANDARD APCL20 CCS (500 mL)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Low-temperature viscosity standard
- Viscosity values from 21,337 mPa.s (-40 °C) up to 862.4 mPa.s (-10 °C)

VISCOSITY STANDARD APCL25 CCS (500 mL)
ViscoQC 100 L | 100 R | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 19,907 mPa.s (-35 °C) up to 1,371 mPa.s (-10 °C)

VISCOSITY STANDARD APCL28 CCS (500 mL)
ViscoQC 100 L | 100 R | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 16,682 mPa.s (-30 °C) up to 2,022 mPa.s (-10 °C)

VISCOSITY STANDARD APCL38 CCS (500 mL)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Low-temperature viscosity standard.
- Viscosity values from 20,950 mPa.s (-25 °C) up to 2,670 mPa.s (-5 °C)

MEASURING BOB CP40
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING BOB CP41
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Temperature control solutions for ViscoQC:
Temperature device PTD 175
ViscoQC 300 L | 300 R | 300 H
- For ViscoQC 300; viscometer and temperature device from a single source
- Air cooling saves tempering time and reduces maintenance costs
- From low-temperature engine oil to high-temperature asphalt binder tests
- Wide-range Peltier device: -45 °C to +175 °C (±0.1 °C)

MEASURING BOB CP52
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING BOB CP51
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING BOB CP42
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

CARRYING CASE ViscoQC
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING CUP PTD 100 Cone-Plate
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING SYSTEM DG26
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

LABEL PRINTER USB BROTHER Label Printer QL-700
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring Cup C-8R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING SYSTEM CC26
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

Measuring System SC4-15/7R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING SYSTEM CC18
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

MEASURING SYSTEM CC12
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

Cone-plate measuring system with integrated Peltier temperature device:
PTD 100 Cone-Plate
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- For small sample volumes from 0.5 mL to 2 mL
- Upgrades ViscoQC 100 and 300 to a cone-plate viscometer
- Two in one: Cone-plate and Peltier temperature device combined
- Automated gap setting process
- Magnetic coupling, Toolmaster™ feature, and temperature probe as standard

MEASURING BOB B-SC4-14
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE GUARD R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for ViscoQC x00 - R

MEASURING BOB B-SC4-15
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE GUARD L
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Recommended for ViscoQC x00 - L

MEASURING BOB B-SC4-16
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

PT100 TEMPERATURE SENSOR
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Comes with a metal clip (mounting clamp) for fixing the Pt100 sensor on the rim of open sample vessels or on the L/R spindle guard.

Measuring Cup C-6R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLESET RH
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring Cup C-7R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLESET L
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring System SC4-14/6R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE RH1
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring System SC4-16/8R
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE RACK
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Temperature control solutions for ViscoQC:
Temperature device PTD 80
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- For ViscoQC 100/300; viscometers and temperature device from a single source
- Air cooling ensures small footprint, and reduces maintenance costs
- Exact sample temperature control of, e.g. chocolate, adhesive
- For routine QC applications from +15 °C to +80 °C (±0.1 °C)

DIN ADAPTER
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Required for measurement with a concentric cylinder (CC), double-gap (DG), ultra-low viscosity adapter (UL), or SSA (SC4) measuring system if not using a Peltier temp. device.

Motorized accessory for ViscoQC 100/300:
Heli-Plus
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Convenient operation thanks to motorized stand instead of manual height adjustment
- Measure paste-like materials (e.g. mayonnaise) with helical T-bar spindle movement
- Simplest spindle exchange saves up to 15 seconds per measurement

KEYBOARD USA USB
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

KEYBOARD GERMAN USB
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE SET T-Bar
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

MEASURING CUP C-CC26
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring System DG26/SS
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

JULABO CORIO C-BT5 BATH THERMOSTAT 20...100 °C +/-0.03 °C, 208-230V/50-60Hz
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires stand for bath thermostat (P/N 194946) and stainless bath cover (P/N 194765) to be mounted on ViscoQC and to operate 600 mL beakers from ambient to +100 °C. 208 V to 230 V / 50 Hz to 60 Hz

MEASURING CUP LOCK
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

STAINLESS BATH COVER FOR 600 ml BEAKER ACCESSORY JULABO CORIO C-BT5 (191891)
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
For Julabo bath thermostat to operate 600 mL beakers

PROTECTING COVER FOR KEYBOARD
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

USB CABLE
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

STAND FOR BATH THERMOSTAT CORIO C-BT5
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
To mount Julabo bath thermostat on ViscoQC

JULABO CORIO C-BT5 BATH THERMOSTAT 20ºC_100°C +/-0.03°C, 100-115V/50-60Hz
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires stand for bath thermostat (P/N 194946) and stainless bath cover (P/N 194765) to be mounted on ViscoQC and to operate 600 mL beakers from ambient to +100 °C. 100 V to 115 V / 50 Hz to 60 Hz

Accessory for ViscoQC 100/300:
Flexible Cup Holder
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
- Ensures your sample is always centered in the right place
- To easily center ½ pint, pint, quart containers, or 600 mL beakers
- Easily mounted on instrument stand
- Guarantees reproducible results

SPINDLESET VANES
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Includes vane spindles V71 to V73.

SPINDLE T-E
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE V75
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Has only full immersion. For very low sample volume.

CLAMP FOR T-Bar SPINDLE
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

Measuring System SC4-21
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

Measuring System SC4-18
ViscoQC 100 R | 100 H | 300 L | 300 R | 300 H
Requires DIN adapter or Peltier temp. device to be mounted on ViscoQC

SPINDLE T-D
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H

SPINDLE T-B
ViscoQC 100 L | 100 R | 100 H | 300 L | 300 R | 300 H