Kinematic Viscometer:
SVM
- Kinematic viscosity at any temperature from 15 °C and 100 °C
- Wide viscosity range without changing capillaries
- High throughput: Up to 33 determinations per hour
- Upgradable to ASTM D4052 density and/or viscosity index
- Optional sample changers for automated sample handling
The SVM kinematic viscometer turns complexity into simplicity. Designed as a true all-in-one powerhouse, this automatic kinematic viscometer delivers much more than just viscosity: kinematic and dynamic viscosity, density, viscosity index, cloud point, freeze point, and more – all at the push of a button. It handles a wide temperature range effortlessly, using integrated Peltier technology, eliminating the hassle of liquid baths.
Trusted worldwide, SVM meets over 50 international standards. Independent ASTM studies show it not only matches but often outperforms D445. Whatever your sample, wherever your lab, the SVM kinematic viscometer is your number one choice.
For budget-friendly routine viscosity testing with minimal sample volume and easy operation, explore the SVM 1001 / 1101 automatic viscometers.
Customized solutions
Key features
The most flexible kinematic viscometer
- Multiple parameters (viscosity, density, viscosity index, API, cloud point, freeze point, and more)
- 0.2 cSt to 30,000 cSt range – measure everything from jet fuel to wax
- No capillary change required
- -60 °C to +135 °C temperature range (SVM 3001)
- Temperature change of up to 20 °C/min (SVM 3001 and 3001 Cold Properties)

Stay compliant and benefit from bias correction
- D7042 is a global standard alternative to D445
- Dual reporting: D7042 and D445 via bias correction
- Complies with ASTM D396, D975, D1655, and 50+ other standards
- ASTM D4052-compliant density included with SVM 3001 and up

Save time with our automatic kinematic viscometers
- 150 % higher throughput compared to manual methods
- Up to 33 determinations per hour
- Temperature equilibration in one minute or less
- Faster results to avoid out-of-spec production

Improve safety for lab and operator
- Metal cell: No more glass breakage
- Peltier thermostatting for fast temperature control
- Reduced exposure to hazardous solvents
- Safer operation: No flammable bath liquids

Minimal sample, solvent, and energy consumption
- Analysis with just 5 mL sample and 6 mL solvent
- Low energy consumption (max. 250 W)
- Two-minute cleaning, 30-minute maintenance
- 50 % less effort for QC documentation
- No external PC or software needed

Digital data handling and automation
- Digital data recording and storage for reliable traceability
- Automatic calculations for error-free measurements
- Compatible with AP Connect for digital data management
- Compatible with heated and non-heated sample changers
- Automated filling and cleaning – even overnight

Specifications
SVM 2001 | SVM 3001 | SVM 3001 Cold Properties | SVM 4001 | |
Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550 | ||
Test methods | ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052 (optional) | ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185 | ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185 ASTM D2386 equiv. or better ASTM D2500 equiv. or better | ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185 |
Measuring Range | ||||
Viscosity | 0.2 mm²/s to 30,000 mm²/s* | |||
Density | 0 g/cm³ to 3 g/cm³ | |||
Temperature | +15 °C to +100 °C | -60 °C to +135 °C | -60 °C to +100 °C | +15 °C to +100°C |
Precision | ||||
Viscosity repeatability** and reproducibility** | 0.1 % and 0.35 % | |||
Density repeatability** and reproducibility** | 0.0002 g/cm³ (0.00005 g/cm² with ASTM D4052 option) and 0.0005 g/cm³ (0.0001 g/cm² with ASTM D4052 option) | 0.00005 g/cm³ and 0.0001 g/cm³ | ||
Cloud/freeze point repeatability** and reproducibility** | - | - | <0.5 °C / <0.5 °C and <2.5 °C / <1.3 °C | - |
Temperature repeatability | 0.005 °C | |||
Temperature reproducibility | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | |
Performance | ||||
Sample volume min. / typical | 1.5 mL / 5 mL | 2.5 mL / 6 mL | ||
Solvent volume min. / typical | 1.5 mL / 6 mL | 2.5 mL / 10 mL | ||
Max. sample throughput | 33 samples per hour | 30 samples per hour | 24 samples per hour | |
Features | ||||
Optional upgrades | Automatic VI determination ASTM D4052-compliant density measurement | Chemical upgrade kit | - | - |
Modularity with Abbemat refractometers 5001, 5101, 5201, 7001, and 7201 | ||||
Accessories | Magnetic particle trap (MPT), hot filling attachment (HFA) | Magnetic particle trap (MPT) | ||
Automation | Optional sample changer + High-Throughput Platform HTV | Optional sample changer + High-Throughput Platform HTV | Optional sample changer + High-Throughput Platform HTV | |
Technical Data | ||||
Data memory | 1,000 measurement results | |||
HID (Human Interface Device) | 10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader | |||
Interfaces | 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 x CAN bus, 1 x RS-232, 1 x VGA | |||
Power supply | AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max. | |||
Ambient conditions | 15 °C to 35 °C, max. 80 % r.h. non-condensing | |||
Net weight in kg | 15.9 kg | 17.6 kg | 18.0 kg | 17.8 kg |
Dimensions (W x D x H) | 33 cm x 51 cm x 23.1 cm | |||
Trademarks | SVM (13411996), FillingCheck (6834725), Abbemat (1084545) |
Standards
ABNT
ASTM
CAN/CGSB
DEFSTAN
DIN
GB
GJB
GOST
IP
IS
ISO
JIG
OENORM
RANP
EN
SH
SN
SAE
Standards
ABNT
API
ASTM
CAN/CGSB
DEFSTAN
DIN
EN
GB
GJB
GOST
IP
IS
ISO
JIG
MIL
OENORM
RANP
SAE
SH
SN
Standards
ABNT
API
ASTM
CAN/CGSB
DEFSTAN
DIN
EN
GB
GJB
GOST
IP
IS
ISO
JIG
MIL
OENORM
RANP
SAE
SH
SN
Standards
ABNT
API
ASTM
CAN/CGSB
DEFSTAN
DIN
EN
GB
GJB
GOST
IP
IS
ISO
JIG
OENORM
RANP
SAE
SH
SN
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Automated Viscosity Measurement of In-Service Oils Application Reports
-
Automated Viscosity Measurement of Raw Materials for Cosmetic Products Application Reports
-
Automotive | SVM 3001: Automotive Brake Fluids Application Reports
-
Aviation | Aviation industry – What SVM can do for you Application Reports
-
Aviation | Cold Flow Properties of Jet Fuel (Freezing Point) Application Reports
-
Aviation | Jet Fuel Viscosity - SVM 3001 Application Report Application Reports
-
Aviation | Viscosity of Aviation Lube Oils and Hydraulic Fluids Application Reports
-
Base Oils, Pharma, Lubricants | Viscosity of White Oils Application Reports
-
Base and Lube Oils | Viscosity Index of Base and Lube Oils with SVM 4001 Application Reports
-
Chemicals | Multiparameter Analysis of AdBlue® Application Reports
-
Cooling Fluids | SVM 3001 – Viscosity Testing of Immersion Cooling Fluids Application Reports
-
E-Book - Analytical Methods for the Evaluation of Lubricants Application Reports
-
E-Book - The Field Guide to Data Integrity in Regulated Industries Application Reports
-
E-Book - The Future of Plant-Based Foods Application Reports
-
Efficiency Meets Sustainability – Biodiesel Measurements Made Easy Application Reports
-
Food | Liquid Food Flavors with SVM 3001 and Abbemat Refractometer Application Reports
Similar products

Rolling and Falling Ball Viscometer:
Lovis 2001 Module

Rolling and Falling Ball Viscometer:
Lovis 2001 Benchtop

Automatic Viscometer:
SVM 1001

Automatic Viscometer:
SVM 1001 Simple Fill

Automatic Viscometer:
SVM 1101 Simple Fill

Rotational Viscometer:
ViscoQC 100 H

Rotational Viscometer:
ViscoQC 100 L

Rotational Viscometer:
ViscoQC 100 R

Rotational Viscometer:
ViscoQC 300 H

Rotational Viscometer:
ViscoQC 300 L

Rotational Viscometer:
ViscoQC 300 R
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.

ISO 17034-Certified Reference Material:
Density Standards
SVM 2001 | 3001 | 4001
- Market-leading uncertainty of 0.015 kg/m³ (ISO 17034)
- Application-specific density standards, available via webshop
- Online certificate with lifetime reference values guarantee
- Conformity with ISO requirements ISO 17025 and even ISO 17034
- Safety glass ampoule for zero contamination

Heated Sample Changer:
Xsample 610
SVM 2001 | 3001 | 4001
- The single sample changer for heavy duty applications
- Heats up samples up to 95 °C (200 °F) for easy filling
- Ideal for crude oil, waxes, and gels
- Automated cleaning and drying enables minimal operator handling
- Compatible with most commercially available syringes

Accessory for Used-Oil Analysis:
Magnetic Particle Trap (MPT)
SVM 2001 | 3001 | 3001 Cold Properties | 4001

Accessory for SVM 2001/3001:
Hot Filling Attachment
SVM 2001 | 3001
- Keeps samples with high melting point in liquid state during tests
- Suitable for waxes, residual fuel oil, vacuum residue, heavy crude oil and more
- Heated by the Peltier system of SVM, thermal insulation ensures absolute safety
- Minimal space required

Sample Changer:
Xsample 340
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- The single sample changer for different syringe sizes
- The robust solution for reliable and repeatable results
- Prevents sample carry-over with automatic rinsing and drying after each sample
- Highly resistant wetted parts for handling aggressive samples

Sample Changer:
Xsample 530
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- The multi-sample changer with the highest cleaning performance
- Handles up to 71 samples with optional sample recovery
- Automated cleaning and drying with up to three solvents
- Customized magazines available for your own vials
- Measurement of volatile samples

Sample Changer:
Xsample 520
SVM 2001 | 3001 | 4001
- The multi-sample changer that provides first-class filling at a snap
- Handles up to 96 samples in one magazine
- Ideal for beer, wine, soft drinks, syrups, and other aqueous samples which can be replaced without intermediate cleaning
- Multiple fillings from the same vial if required

Lab Execution System:
AP Connect Start
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule

Lab Execution System:
AP Connect Standard subscription license
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Standard one-time license
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Pharma subscription license
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Pharma one-time license
SVM 2001 | 3001 | 3001 Cold Properties | 4001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips