MCR Rheometer Setups for:
Powder

  • +11
  • 360°
Model:
  • Accurate powder analysis with the powder flow cell and shear cell
  • True powder rheology to analyze bulk solids in any state, from fluidized to consolidated powders
  • Wide range of dedicated powder measurement methods for quality control and R&D
  • Suitable for measurements from -160 °C to +980 °C (and combinable with humidity control)
  • Enables the characterization of powders under low to high loads and their time-dependent behavior
  • Shear, compressibility, and wall friction tests

The two cells for true powder rheology help you to really characterize and understand your powders. A wide range of dedicated powder measurement methods is available putting the advantages of rheometers to use: fast and easy-to-perform tests but also elaborate measurements for both quality control and R&D purposes.

The powder shear cell is ideal for determining the flow behavior of consolidated powders and their time-dependent behavior. Additional accessories provide full control over temperature and humidity.

The powder flow cell is an innovative and scientific approach towards powder characterization offering a wide range of test methods. Powder behavior can be characterized under various processing conditions: simulating, adjusting, and optimizing – for example – manufacturing processes.

Key features

Two cells to cover all your needs

Two cells to cover all your needs

The complete powder rheology setup with the powder shear cell and the powder flow cell gives you all the possibilities you need for the characterization of your powders and granular media. The combination of a rheometer with a system to determine the behavior of powders guarantees the highest sensitivity and absolute results. 

The most versatile powder characterization with the powder flow cell

The most versatile powder characterization with the powder flow cell

Due to its high versatility, the powder flow cell can be used for in-depth powder characterization or as an easy-to-use quality control tool: You can use it to control the quality of your products with quick tests while benefitting from the precision of Anton Paar’s MCR rheometers. Use one of the many measurement methods, such as basic flowability energy, cohesion strength, pressure drop, deaeration time, etc., to characterize your powder as it is during processing, handling, and storage. On top of that, you can also determine envelope density using the powder flow cell with a dedicated measuring geometry and displacement powder.

The only powder shear cell with temperature and humidity control

The only powder shear cell with temperature and humidity control

Control the temperature and find out how this impacts your powders. An MCR rheometer can be equipped with heating chambers for an extreme temperature range from -160 °C to 980 °C. Humidity is known to heavily change powder behavior during storage, handling, and processing and can be controlled in the range between 5 %rH and 95 %rH with a dedicated humidity kit. Temperature and humidity control are also available for the powder flow cell on request as a customized solution.

Powerful software for incomparable control

Powerful software for incomparable control

With the intuitive user interface of the rheometer software you can run fully automatized measurements with only two clicks while maintaining full autonomy over all measurement parameters. You can adapt all measurements to your needs. The system complies with QM requirements, such as 21 CFR Part 11 for the pharmaceutical industry, and can be used with Windows 10 or higher.

Patented dust protection for the powder flow cell

Patented dust protection for the powder flow cell

The unique patented dust protection system (EP 3067684) enables clean and safe sample handling. The fourfold sealing concept protects the operator and the instrument from fine and potentially hazardous powder even when it is fully fluidized. The air seal technology of the powder flow cell is dustproof without any friction on the measurement axis and thus maintains the MCR rheometer’s extraordinary accuracy and resolution down to 10 nNm and below.

Designed for sensitivity and reproducibility

Designed for sensitivity and reproducibility

Expect reproducible measurements for both the powder shear cell and the powder flow cell. The MCR’s sensitivity helps to differentiate even very similar powders and detect even small changes within your samples. A sample preparation bench is included in the powder shear cell setup. It ensures that the samples are always prepared identically, strongly reducing operator influence and thereby increasing reproducibility. The powder flow cell applies automated sample preparation modes for an unrivalled reproducibility of up to 0.5 %.

Technical specifications

  Powder shear cell PFC 30 PFC 20 PFC 10
Sample volume 4.3 mL and 18.9 mL 60 mL to 120 mL 60 mL to 120 mL 21 mL
Torque range 1 nNm to 300 mNm 10 nNm to 300 mNm
Normal stress While shearing: up to 30 kPA
While compacting: up to 110 kPA
(sample- and cell-dependent)
22 kPa -
Temperature option -20 °C to +180 °C with CTD 180 HR
-160 °C to +600 °C with CTD 600 MDR
-100 °C up to +980 °C with CTD 1000 MDR
-15 °C to +80 °C -160 °C to +600 °C
Humidity option 5 %rH to 95 %rH
from 5 °C to 120 °C with CTD 180 HR and humidity option
Customizable on request -5 %rH to +95 %rH from 5 °C to 120 °C with CTD 180HR and humidity option
Meaurement systems compatible

Included in the setup:

  • Small shear system (4.3 mL)
  • Large shear system (18.9 mL)
  • Wall friction system with exchangeable discs (stainless steel, aluminum, PTFE, further materials on request)
 Two-blade stirrer - helical two-blade stirrer - warren-springs geometry - powder preparation set with
exchangeable disks (stainless
steel, air-permeable, PTFE,
further materials on request)
- Cylinder - profiled cylinder
Basic flowability energy stirrer (further stirrers on request); not compatible with PFC 20 and 30 stirrers
Measurement method
  • Shear measurements (with temperature and humidity)
  • Time consolidation
  • Wall fricton and adhesion
  • Compressibility (bulk density, Carr index, Hausner ratio)
  • Easily customizable methods
For fluidized, aerated and low-load conditions For non-fluidized, aerated and low-load conditions For non-fluidized, aerated conditions (BFE and SE)
Dust protection Not necessary incl.  Upgrade kit to PFC 30 available no
Fluidization option Not necessary Choice of 3 mass flow controllers for volumetric flow from 0.05 L/min up to 80 L/min. Only with upgrade kit no
Accessories

Included in the setup:

  • Sample preparation / time consolidation bench
  • Weight base for small and large shear cell


Weights for small and large shear cell (up to 12 kPA in 1 kPA step)

Included in the setup: ø 50 mm PFC with uncoated glass; dust protection hood and fluidization option Included in the setup: ø 50 mm PFC with uncoated glass Included in the setup: ø 24 mm PFC made of stainless-steel, funnel for PFC, basic flowability stirrer
Optional: FTO-coated glass/ steel tube Optional: Measuring cup made of inconel or disposable cup

Standards

Open all
Close all

ASTM

D6773 Shear Cell

DIN

1055 Shear Cell

DIN EN ISO

8130-15:2024-01 Flow Cell

ISO

8130-15:2023 Flow Cell

Pharmacopoeia Europe (Ph. Eur.)

2.9.49. Shear Cell

U.S. Pharmacopoeia (USP)

1174 Shear Cell

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Product
Your choice: Reset all filters

No results found!

See more

Compatible instruments

Consumables

Consumables

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

PFC UPDATE KIT FOR ENVELOPE DENSITY

Compatible with:
Powder Shear Cell
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 310251
Product details
Incl.
- Uncoated Measuring Tube
- Funnel Piece PFC (with mounted sealing ring)

ENVELOPE POWDER

Compatible with:
Powder Shear Cell
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 314877
Product details
Spare part for Envelope Density Set
- Glass beads 800g

COMPRESSION DISCS FOR ENVELOPE DENSITY

Compatible with:
Powder Shear Cell
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 315763
Product details
Spare part for Envelope Density Set
- 5 pcs of PEEK compression discs

ENVELOPE DENSITY SHAFT PP50/187/PE/PFC

Compatible with:
Powder Shear Cell
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 267619
Product details
Spare part for Envelope Density Set