This is a required field.
Invalid
Part number
Error in validation!

Advanced Rheometer:
MCR 703

  • +9
Model:
  • Advanced rheometer with unrivaled variety of working modes
  • Highest precision for sophisticated research
  • Expansion of material characterization with counter-movement mode
  • DMA in torsion, tension, bending, and compression
  • 200+ accessories for endless possibilities in research and development

MCR 703 MultiDrive and MCR 703 Space MultiDrive are the most versatile advanced rheometers available. Alongside all the standard features of the MCR 503, they can also be equipped with an additional lower drive unit. This means you can perform rheological tests with two torque transducers and drive units at once, opening up multiple possibilities for your research. There are no limitations regarding test modes, measuring systems, accessories, temperature devices, and measurement precision. Additionally, MCR 703 Space MultiDrive offers maximum working space, making it easy to work with accessories and additional instruments. 

Key features

One rheometer, all rheological working modes

This is the perfect rheometer for advanced measurement-precision requirements. A combination of two drive units enables you to perform rheological measurements in Combined Motor Transducer (CMT) mode and in Separate Motor Transducer (SMT) mode. Using a single air-bearing-supported EC motor in CMT mode, you can make the most of the motor’s real-time position control (TruStrain) and perform ‘classic’ stress-controlled tests. In SMT mode, one motor is operated solely as a torque transducer, while the other is used as the drive unit to get the purest results. This makes the advanced rheometer ideal even for transient regimes such as stress relaxation, start-up shear measurements, or oscillatory tests across a wide frequency range.

* Measuring
** Driving
 

Push the limits of material characterization

In counter-movement mode, the advanced rheometer employs both air-bearing-supported EC motors as drive units, as well as torque transducers which move in opposite directions. Create, for example, a fixed stagnation plane in a sample while visualizing with a microscope for advanced structure analysis throughout the full measurement. In combination with the universal extensional fixture, this mode also permits extensional tests down to minimal measured torques and up to unachieved elongations with Hencky strains larger than eight. With these capabilities, this advanced rheometer offers more comprehensive characterization of strain hardening. The counter-movement mode simply doubles the speed score up to a maximum speed difference of 6,000 rpm.

DMA in torsion, tension, bending, compression, and more

MCR 703 is more than just a rotational rheometer – it’s a multifunctional advanced rheometer that also supports dynamic mechanical analysis (DMA). By replacing the lower rotational drive with a linear drive, it performs DMA in bending or compression using geometries such as three-point-bending, cantilever, or parallel plates. Furthermore, in combination with geometries for films, fibers, and rectangular and cylindrical samples, the linear drive can be used to perform DMA in tension, while the upper rotational drive is used for DMA in torsion. This also enables axial-torsional DMA on a single specimen within a single test definition, and allows determination of the Poisson’s ratio and fast direction-dependent characterization of anisotropic materials.

Previously unthinkable applications

MCR 703 Space MultiDrive takes the exceptional performance of our flagship rheometer MCR 703 MultiDrive even further. It's engineered to offer unique modularity, flexibility, freedom, and functionality for any type of rheology and combined methods. The open instrument design maximizes working space so you can connect MCR 703 Space MultiDrive with a variety of additional external setups for advanced material characterization (e.g., confocal microscopy and rheology at the same time). In addition, the rheometer's separate electronics box now makes it possible to set up the rheometer where space is limited or in a laboratory glovebox, even when using inert gas (nitrogen, argon) atmosphere (e.g., for high-temperature measurements of samples with a certain hazard level).

More than 200 accessories

MCR 703 MultiDrive and MCR 703 Space MultiDrive can be paired with any measuring system, temperature device, and/or application-specific accessory recognizable from the Anton Paar MCR series, in order to carry out standard and sophisticated rheological analyses. This allows the testing platform to be used not only for rheology and DMA but also as a powder rheometer, tribometer, and universal testing machine. The Toolmaster feature automatically recognizes and configures all connected devices and measuring systems. Additionally, the QuickConnect function allows one-handed connection of the measuring systems. This modularity makes our advanced rheometers highly flexible and ensures that adaption of the configuration to your needs is straightforward.

Specifications

 MCR 703 MultiDrive
MCR 703 Space MultiDrive
 Configuration with 1 EC motor Configuration with 2 EC motors 
Bearing designAir, fine-pored carbon
Motor designElectronically commutated (EC) permanent magnet synchronous motor
Displacement transducerHigh-resolution optical encoder
Normal force measurement design360° capacitive sensor, non-contacting, fully integrated in bearing
Working modesCMTCMT, SMT, Counter-Movement1)
Min. torque (rotation)1 nNm1 nNm
Min. torque (oscillation)0.2 nNm0.2 nNm
Max. torque230 mNm230 mNm
Torque resolution0.05 nNm0.05 nNm
Angular deflection resolution< 1 nrad
Min. angular velocity2)0 rad/s
Max. angular velocity / max. speed314 rad/s
3,000 rpm
628 rad/s
6,000 rpm
Min. frequency3)2 Hz x 10-8 Hz
Max. frequency200 Hz
Normal force range0.001 N to 50 N
Gap resolution0.0625 µm
TruStrain
Ready for DMA in tension, bending, and compression
Ready for axial-torsional DMA4)
Active thermal management of motor
With  exposed support plate5)
Dimensions (W x H x D)MCR 703 MultiDrive: 453 mm x 775 mm x 673 mm
MCR 703 Space MultiDrive: 300 mm x 775 mm x 584 mm
Electronic box: 333 mm x 231 mm x 576 mm
WeightMCR 703 MultiDrive: 50 kg
MCR 703 Space MultiDrive: 52 kg
Electronic box: 16 kg
MCR 703 MultiDrive: 60 kg
MCR 703 Space MultiDrive: 62 kg
Electronic box: 16 kg

Trademarks: RheoCompass (917 7015), MultiDrive (16731581), TwinDrive Rheometry (7081128), SmartPave (16731556), T-Ready (9176983), Toolmaster (3623873), TruRate (9176967), TruRay (15273915), TruStrain (9176918)
Patents: US Pat. 8453496, 9766172, 9574983, 10908058, 8132445, 10031057, 9702809, AT Pat. 513661, DE Pat. 102015100714

 ✓ included | o optional | x not included

1) US Pat. 8453496
2) In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode depending on measuring point duration and sampling rate.
3) Theoretical value (duration per cycle = 2 years).
4) US Pat. 9574983 and US Pat. 10908058.
5) MCR 703 Space MultiDrive: Unique maximized workspace below the rheometer support plate and on both sides of the instrument
 

Standards

Open all
Close all

ASTM

D4440
D4473
D5279

DIN

1342 1-3
3219
13343
51810 Part 1
51810 Part 2
53019-1
53019-2
54458

DIN EN ISO

8130-15:2024-01

EN

3219
14770

ISO

3219
6721-1

European Pharmacopoeia (Ph. Eur.)

2.2.8. Viscosity
2.2.10. Viscosity - Rotating viscometer method
0132

US Pharmacopoeia (USP)

912 - Viscosity - Rotational Methods

Standards

Open all
Close all

ASTM

D4440
D4473
D5279

DIN

1342 1-3
3219
13343
51810 Part 1
51810 Part 2
53019-1
53019-2
54458

DIN EN ISO

8130-15:2024-01

EN

3219

DIN EN

14770

ISO

3219
6721-1

European Pharmacopoeia (Ph. Eur.)

2.2.8. Viscosity
2.2.10. Viscosity - Rotating viscometer method
0132

US Pharmacopoeia (USP)

912 - Viscosity - Rotational Methods

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Similar products

Complementary products

Product Type
  • Accessory
  • Software
Category
  • Additional Parameter Settings
  • Cell
  • Cup Holder
  • Dielectric Spectrometer
  • Electro-Rheological Device
  • Geometries
  • Laboratory Software
  • Low Temperature Options
  • Microscope
  • Plate
  • Pressure Cell
  • Set
  • Structure Analysis
  • Structure Analysis and Rheo-Optics
  • Temperature Control

Rheometer Software:
RheoCompass 

Compatible with :
MCR 703 MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Software for your Anton Paar rheometer
  • Predefined templates and analysis methods
  • Report and automation functions
  • Customized test definitions and analysis methods in detail
  • Compliant with QM regulations such as GLP/GMP and 21 CFR Part 11

More info

Accessory for MCR and RheolabQC:
Flexible Cup Holder 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for “Extended Material Characterization"
  • Holds, for example: paint cans, yogurt cups, other containers
  • Can be combined with stirrers, concentric cylinder geometries, and a Pt100 temperature sensor

More info

Temperature Control for MCR:
Liquid Temperature Devices (LTD) 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • For measurements at constant temperatures from -30 °C to +180 °C
  • For parallel-plate, cone-plate, concentric cylinder, and double-gap measuring geometries

More info

Temperature Control:
Peltier Systems with TruGap™ 

Compatible with :
MCR 703 MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • TruGap™ measures the real gap size to ensure accurate measurements even if the measuring temperature changes
  • No loss of accuracy: set the zero-gap at any temperature you want
  • Reduces waiting times: T-Ready™ detects when temperature equilibrium is reached and starts the test automatically

More info

Accessory for MCR:
Cone Partitioned Plate 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • For viscoelastic samples when performing LAOS and transient tests
  • Reduces the impact of edge fracture effects
  • Reduces errors due to sample trimming

More info

Temperature Control:
Convection Temperature Devices (-160 °C to +1000 °C) 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • For temperature-controlled rheological and DMA measurements performed on melts, solids, films, and fibers from -160 °C to +1000 °C
  • Homogeneous temperature distribution for accurate and stable results
  • For MCR measuring systems: parallel-plate, cone-plate, DMA in torsion or extension, controlled relative humidity, and more

More info

Accessory for MCR:
Dielectric Spectrometer 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Combine rheology and dielectric spectroscopy
  • Study a material’s response to an applied electric field
  • Gain information on a material’s structure and behavior

More info

Accessory for MCR:
Electrorheological Device 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for “Additional Parameter Settings”
  • Characterization of electrorheological fluids
  • Electric field of up to 12.5 kV can be applied
     

More info

MCR Rheometer Setups for:
Envelope Density 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 310063
Product details
  • Envelope density setup from the leader in powder characterization
  • Buy an envelope density device and benefit from full rheometer functionality
  • Budget-friendly option for envelope density determination
  • 21 CFR Part 11-compliant
  • Automatic detection of setup to save time and eliminate errors

More info

Accessory for MCR:
Humidity Option 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for “Additional Parameter Settings”
  • Controls the impact of the relative humidity on a material’s rheological behavior

More info

Accessory for MCR Temperature Devices:
Low-Temperature Options 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Combinable with electric and convection temperature devices
  • Tailor-made solutions for low temperatures down to -15 °C, -90 °C, or -170 °C
  • Toolmaster functionality for automatic system configuration and error-proofing

More info

Option for a Rheometer with two EC Drives:
Rheo-Microscopy Setup 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Flow visualization in the stagnation plane
  • Characterization of microstructural changes at higher shear rates
  • Direct assignment of images and videos to rheological data

More info

Accessory for MCR:
Particle Imaging Velocimetry 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for structure analysis and rheo-optics
  • For visualization of flow fields

More info

Temperature Control for MCR:
Peltier Systems 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Effective and convenient heating and cooling
  • Air cooled Peltier hood and plate; sustainable and cost efficient
  • Temperature control with minimized temperature gradients from -50 °C to +220 °C
  • Modular system for combination with rheo-optics accessories
  • For cone-plate, parallel-plate, and cylinder measuring systems

More info

Accessory for MCR:
Pressure Cell 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • For investigation of the effect of pressure on rheological properties
  • Unique pressure range of up to 1,000 bar
  • Choose between gas or liquid pressurization 

More info

Rheo-Confocal Microscopy:
MCR 703 Multidrive Space and Rheo-Optics 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for structure analysis: Rheology meets confocal microscopy
  • Highly versatile MCR rheometer with maximum working space, for sophisticated research

More info

Optical Accessory for MCR:
Rheometer-Infrared Spectrometer Adapter 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for structure analysis and rheo optics
  • Connects your infrared spectrometer to an MCR rheometer
  • Investigates chemical composition and rheology

More info

Accessory for MCR:
Rheometer Geometries 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Wide range of measuring systems for RheoLabQC and the MCR rheometer series
  • Concentric-cylinder, double-gap, cone-plate, and parallel-plate systems; vane geometries and spindles; Krebs spindles
  • Customized solutions upon request

More info

Accessory for MCR:
Starch Cell 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 16083
Product details
  • Accessory for extended material characterization
  • Starch pasting cell for analysis of starch gelatinization or pasting behavior
  • Max. heating rate: 60 °C/min; max. cooling rate: 45 °C/min
     

More info

Optical Accessory for MCR:
UV Light Curing System 

Compatible with :
MCR 703 MultiDrive | Space MultiDrive
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Accessory for additional parameter setting
  • For the investigation of UV-curing reactions
  • Simultaneous characterization of rheological behavior and UV-light-initiated curing
  • Built-in temperature control
  • LED and mercury light sources available

More info

See more