此为必填字段。
Invalid
零件型号
验证错误!

BET 比表面积分析仪:
Nova

  • Anton Paar Nova 800 BET Surface Area Analyzer with open cabinet, two analysis ports, Dewar flask, and external monitor displaying adsorption isotherms
  • Technician operating Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with open cabinet, sample ports, Dewar flask, and external monitor displaying measurement data
  • Technician inserting glass sample tube into Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer, open cabinet with analysis ports and Dewar flask visible
  • Technician inserting sample tubes into analysis ports of the Anton Paar Nova 800 BET Surface Area Analyzer, close-up of metal fittings and glass tubes
  • Gloved technician connecting multiple glass sample tubes to analysis ports inside Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer
  • Technician inserting glass sample tubes into analysis ports of Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with touchscreen display and Dewar flask
  • Gloved technician positioning Dewar flask inside Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer beneath glass sample tubes
  • Gloved technician selecting analysis method on touchscreen of Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer, analysis ports visible
  • Technician operating Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with open cabinet, sample ports, Dewar flask, and external monitor showing Nova software
  • External monitor displaying Anton Paar Nova software interface for Nova 800 BET Surface Area and Pore Size Analyzer with report template selection window
  • media
  • media
  • media
  • media
  • Anton Paar Nova 800 BET Surface Area Analyzer with touchscreen display, two analysis ports with sample tubes, and integrated Dewar in open cabinet
  • Anton Paar Nova 800 BET Surface Area Analyzer with open cabinet, two analysis ports, Dewar flask, and external monitor displaying adsorption isotherms
  • Technician operating Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with open cabinet, sample ports, Dewar flask, and external monitor displaying measurement data
  • +10
  • 360°
型号:
  • 借助这款多工位 BET 比表面积分析仪,提升预算使用效率
  • 借助 2 个分析站和多达 8 个脱气站,提升样品通量
  • 采用短样品管和 NOVA 模式,降低氦气消耗
  • 对于表面积 ≥2 m2 的样品,可实现 2 % 的重现性
  • 借助内置配置文件,简化分析流程

Nova BET 比表面积分析仪在比表面积和孔径分析领域树立了新的标杆。 

最多可配备 8 个脱气站和 4 个分析站,可在分析样品的同时对其他样品进行脱气处理。 约 20 分钟即可完成 4 个样品的五点 BET 测定,重现性为 2 %。 自动脱气意味着无需操作人员干预。

操作简便。测量精准。分析快速。Nova。

关键功能

集成式样品制备,简化您的流程

采用紧凑型一体化设计,集成 8 个脱气站和最多 4 个分析站,无需外接脱气装置,从而减少占地、节约成本并降低系统复杂性。 可在真空条件下或采用流动气体脱气方式,对多种样品进行预处理,最高温度可达 425 ºC。 脱气程序可通过软件进行设定,并与对应的样品 ID 关联,便于实现完整追溯。 这些集成式脱气站可确保样品在使用 BET 比表面积分析仪进行分析前得到充分制备。

Gloved technician connecting multiple glass sample tubes to analysis ports inside Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer

加快单点 BET 比表面积测定,降低成本

直观的触摸屏界面让操作人员可直接在仪器上启动分析,而简便的设置以及无需外接气源即可运行的设计,使其适用于生产现场。
Nova Nitro ReGen 方案的优势在于:可将杜瓦瓶中蒸发的纯氮直接输送至仪器,供测试使用。 这样便无需使用钢瓶,可简化系统配置,有助于获得准确且重复性良好的 BET 结果,并降低环境影响和实验室成本。
Nova 脱气附件同时支持真空脱气和流动脱气,用户可灵活选择最适合其样品的方法。 这可减少对多台脱气仪的需求,并有助于降低设备成本。

Technician inserting glass sample tubes into analysis ports of Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with touchscreen display and Dewar flask

TruZone – 冷却液液位主动控制

借助 TruZone,可在样品池上形成并维持局部冷区,从而显著提高比表面积与孔径分析的测量灵敏度。 提高对样品所吸附气体分子的测量灵敏度,可带来卓越的测量性能。 Nova BET 比表面积分析仪 即使在样品池中样品总表面积低至 2 m² 时,重现性仍优于 2 %。 基于这一性能,该仪器可测量比表面积低至 0.01 m²/g 的材料。

Gloved technician positioning Dewar flask inside Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer beneath glass sample tubes

智能定量投气算法套件,轻松创建方法

DoseWizard、VectorDose 和 Initial Fill 等智能投气算法可简化分析配置文件的创建,在不牺牲精度的情况下加快分析速度。 结合适用于 ASTM、ISO、USP 和 DIN 等标准方法的 20 多种内置分析配置文件,这款比表面积及孔径分析仪可在整个流程中实现简便操作。

Gloved technician selecting analysis method on touchscreen of Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer, analysis ports visible

配备智能软件的比表面积及孔径分析仪

借助 Kaomi for Nova,实现仪器控制与数据处理一体化。 可轻松完成分析设置与执行,以及数据处理、报告生成和存储。 通过一台 PC 最多可控制四台 Nova BET 比表面积分析仪。 

Technician operating Anton Paar Nova 800 BET Surface Area and Pore Size Analyzer with open cabinet, sample ports, Dewar flask, and external monitor showing Nova software

符合 21 CFR Part 11 要求的软件

借助 Kaomi for Nova 21 CFR Part 11 软件(用户管理、审计追踪、可自定义报告和电子签名),提升制药行业中的数据完整性。 

该软件可确保您的 BET 比表面积分析仪满足 FDA 21 CFR Part 11 要求,确保数据具备完整的可追溯性和安全性,并配套全面的制药行业确认与再确认套件。

External monitor displaying Anton Paar Nova software interface for Nova 800 BET Surface Area and Pore Size Analyzer with report template selection window

规格

 Nova 600 BETNova 800 BETNova 600Nova 800
分析规格
测量原理真空体积法
分析气体仅限 N2 N2、Ar、CO2及其他非腐蚀性气体
分析工位2424
独立 P0 工位
相对压力范围 (P/P0 )10-4 至 0.510-4 至 0.999
压力测量精度0.1 %(满量程) *
压力分辨率绝对压力:1.2 x 10-4
Torr 相对压力:1.5 x 10-7 P/P0
比表面积下限从 0.01 m2/g
绝对表面积下限自 0.5 m2
比表面积重复性 2 %**
孔径范围不适用0.35 - 500 nm(直径)
(使用 CO2 时为 0.35 - 1.1 nm)
(使用 N2 时为 1.1 - 500 nm)
最小孔径值N/A1.2x10-8 cm3
Truzone
Powerprotect
Dosewizard
Vectordose
分析杜瓦瓶容量:1 L
持续时间:最长 7 小时
容量:2 L
持续时间:最长 40 小时
样品制备集成脱气站:4 个
温度控制:2 个加热区,环境温度至 425 oC
可用方法:流动和真空,可编程多步加热程序
物理规格
尺寸(深x宽x高)44 cm x 63 cm x 84 cm
重量63 kg
工作环境温度:15 至 35 oC
湿度:20 % 至 80 % 相对湿度,无冷凝
接液部件不锈钢,Viton 弹性体
气体接口:5 个(3 个分析接口、1 个氦气接口、1 个脱气/回填接口)
纯度:99.999 %(He、N2
输入压力:8 至 10 PSIG
真空接口旋转泵排气口,KF 16
真空要求极限真空度为 2.3 x 10-3 Torr
电气电源:AC 100~240 V AC,50 / 60 Hz 功耗:345 VA(最大)
附加规格
显示屏10 英寸触摸屏
PC 连接 以太网
适用于 Nova Software 的 Kaomi仪器控制:最多 4 台仪器 
6 种语言:英语、法语、德语、日语、中文、西班牙语
用于 Nova 21 CFR Part 11 软件的 Kaomi功能:用户管理、审计追踪、可定制报告和电子签名,有助于提升制药行业应用中的数据完整性
制药确认套件
预加载分析配置文件20+(ASTM、USP、DIN、ISO)
符合 ROHS 3
CE 认证

* 包括整个压力测量系统的精度、线性度和滞后
** 采用 BAM P115 有证标准物质测得

标准

全部打开
关闭所有

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

CFR

21 Part 11

标准

全部打开
关闭所有

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

CFR

21 Part 11

标准

全部打开
关闭所有

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

CFR

21 Part 11

标准

全部打开
关闭所有

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

CFR

21 Part 11

安东帕认证服务

无论您身在何处,我们都将为您的仪器提供
  • 三年标准保修支持
  • 产品停产后至少 10 年内保证提供原厂配件和维修服务,以及持续的仪器生命周期支持。
  • 仪器维护、验证和优化
  • 遍布 110 多个国家/地区的认证工厂培训专家提供快速可靠的支持
更多详情

文档

类别:
行业
应用
您的选择: 重置所有筛选条件

未找到结果!

了解更多信息

互补产品

产品类型
  • 配件
类别
  • 其他
  • 样品制备

Nova的增强选项:
脱气配件 

兼容 :
BET 比表面积分析仪:Nova 600 BET | 800 BET | 600 | 800
仅为在线购买价格 不含包含 0增值税
交货时间: %1$s – %2$s 工作日 %1$s – %2$s 周 %1$s – %2$s 月
零件型号 : 316060
产品详情
  • 在八个样品冷却时处理八个样品
  • 加热至425 ℃,具有两个加热区域的灵活性
  • 选择保持加热器开启以实现更快的周转时间
  • 能够进行真空和流动脱气
  • 持续跟踪脱气信息,甚至在分析报告中

更多信息

外部脱气装置:
FloVac 

兼容 :
BET 比表面积分析仪:Nova 600 BET | 800 BET | 600 | 800
仅为在线购买价格 不含包含 0增值税
交货时间: %1$s – %2$s 工作日 %1$s – %2$s 周 %1$s – %2$s 月
零件型号 : 385955
产品详情
  • 一次性进行六个样品的脱气,同时对另外六个样品进行冷却
  • 将样品从室温加热至 425 ℃
  • 保持加热器开启以实现更快的周转时间
  • 进行真空和流动脱气
  • 轻松设置加热和冷却速率

更多信息

了解更多信息