BET surface area analyzer:
Nova
- Maximize budgets with the multi-station BET surface area analyzer
- Boost throughput with two analysis and degassing stations
- Conserve helium using short sample cells and NOVA mode
- Achieve 2 % reproducibility with ≥2 m2 measurement surface area
- Simplify the analysis process with built-in profiles
The Nova BET surface area analyzers have set a new benchmark in surface area and pore size analysis.
Four degassing stations and up to four analysis stations let you degas samples while analyzing others. Analyze four 5-point BETs in approximately 20 minutes with 2 % reproducibility. Automated degassing means no operator intervention is necessary.
Simple. Precise. Fast. Nova.
Key features
Integrated sample preparation simplifies your process
Eliminate the clutter, cost, and complexity of external degassing devices with four integrated degassing stations and up to four analysis stations in one space-saving design. Prepare a range of samples within a vacuum or for flow degassing at temperatures up to 425 ºC. Degassing is software programable and linked with an individual sample ID, ensuring full traceability.
Speed up your surface area and pore size analysis and save costs
Utilize the Nova Mode. Use pre-calibrated sample cells – no need to measure void volumes before every analysis – and accelerate your analyses while maintaining a high level of measurement precision.
Benefit from the Nova Nitro ReGen concept: Channel the pure nitrogen gas evaporating from its Dewar to the instrument for use in experiments. This eliminates cylinders and simplifies setup while delivering accurate, repeatable BET results, and reducing environmental impact and lab costs.
TruZone – active coolant level control
With TruZone, create and maintain a small cold zone on the sample cell and maximize the measurement sensitivity of your surface area and pore size analyzer. Increase sensitivity when measuring gas molecules that are adsorbed by the sample results in exceptional measurement performance. Nova instruments deliver better than 2 % reproducibility with as low as 2 m2 total surface area in the sample cell. This best-in-class performance lets you measure materials with specific surface areas as low as 0.01 m2/g.
Suite of smart dosing algorithms for effortless method creation
Intelligent dosing algorithms, such as DoseWizard, VectorDose, and Initial Fill, simplify the creation of analysis profiles to accelerate analyses without sacrificing precision. In combination with the 20+ built-in analysis profiles for standardized methods like ASTM, ISO, USP, and DIN, our surface area and pore size analyzer delivers operational simplicity from start to finish.
A surface area and pore size analyzer with smart software
Combine instrument control and data processing with Kaomi for Nova. Set up and perform analyses, and process, report, and store data easily. Control up to four Nova BET surface area analyzers from one PC.
21 CFR Part 11-compliant software
Enhance data integrity for the pharmaceutical industry with Kaomi for Nova 21 CFR Part 11 Software (user management, audit trail, customizable reporting, and electronic signature). Comply with the FDA’s 21 CFR Part 11 guidelines with our comprehensive pharma qualification and requalification package.
Technical specifications
Nova 600 BET | Nova 800 BET | Nova 600 | Nova 800 | |
Analysis specifications | ||||
Measurement principle | Vacuum Volumetric | |||
Analysis gases | N2 only | N2, Ar, CO2, and other non-corrosive gases | ||
Analysis stations | 2 | 4 | 2 | 4 |
Independent P0 station | Yes | |||
Relative pressure range (P/P0 ) | 10-4 to 0.5 | 10-4 to 0.999 | ||
Pressure measurement accuracy | 0.1 % (of full scale) * | |||
Pressure resolution | Absolute : 1.2 x 10-4 Torr Relative : 1.5 x 10-7 P/P0 | |||
Lower specific surface area limit | From 0.01 m2/g | |||
Lower absolute surface area limit | From 0.5 m2 | |||
Surface area reproducibility | 2 %** | |||
Pore size range | N/A | 0.35 - 500 nm (Diameter) (0.35 - 1.1 nm with CO2) (1.1 - 500 nm with N2) | ||
Minimum pore value | N/A | 1.2x10-8 cm3 | ||
Truzone | Yes | |||
Powerprotect | Yes | |||
Dosewizard | Yes | |||
Vectordose | Yes | |||
Analysis dewar | Volume: 1 L Duration: Up to 7 Hours | Volume: 2 L Duration: Up to 40 Hours | ||
Sample preparation | Integrated Degassing Stations : 4 Temperature Control: 2 Heating Zones, Ambient to 425 oC Available Methods: Flow & Vacuum, Programable Multi-Step Heating Profiles | |||
Physical specifications | ||||
Dimensions (DxWxH) | 44 cm x 63 cm x 84 cm | |||
Weight | 63 kg | |||
Operating environment | Temperature : 15 to 35 oC Humidity : 20 to 80 % relative, non-condensing | |||
Wetted parts | Stainless steel, Viton elastomers | |||
Gas | Ports: 5 (3 Analysis, 1 Helium, 1 Degas/Backfill) Purity: 99.999 % (He, N2) Input Pressure: 8 to 10 PSIG | |||
Vacuum connection | Rotary Pump Exhaust Port, KF 16 | |||
Vacuum requirements | Ultimate vacuum of 2.3 x 10-3 Torr | |||
Electrical | Supply : AC 100~240 V AC , 50 / 60 Hz Consumption: 345 VA (Maximum) | |||
Additional specifications | ||||
Display | 10-inch Touchscreen | |||
PC connection | Ethernet | |||
Kaomi for Nova Software | Instrument Control: Up to 4 Instruments 6 Languages: English, French, German, Japanese, Chinese, Spanish | |||
Kaomi for Nova 21 CFR Part 11 Software | Features: User management, audit trail, customizable reporting, and electronic signature to enhance data integrity for use in the pharmaceutical industry | |||
Pharma Qualification Package | Yes | |||
Pre-loaded analysis profiles | 20+ (ASTM, USP, DIN, ISO) | |||
ROHS 3 compliant | Yes | |||
CE certified | Yes |
* Includes precision, linearity, and hysteresis s of the complete pressure measurement system
** Performed with BAM P115 certified reference material
Standards
ASTM
DIN
ISO
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Advantages of QSDFT for Pore Size Analysis of Carbons Application Reports
-
Analysis of Carbon Black Surface Area: NSA (BET) and STSA Application Reports
-
Defining Nova 600 | 800 Series Equilibration Parameters Application Reports
-
E-Book - Field Guide to Battery Materials Characterization – Revised and Updated Application Reports
-
E-Book - Field Guide to Food Powder Characterization Application Reports
-
E-Book - Field Guide to Pharmaceutical Powder Characterization Application Reports
-
Graphene Characterization Application Reports
-
Lactose Monohydrate: Density and Surface Area - Nova and Ultrapyc Application Reports
-
Material Brief: Battery Cathode BET Surface Area – Nova 600 | 800 Series Application Reports
-
Material Brief: Graphite – BET Surface Area – Nova 600 | 800 Series Application Reports
-
Material Brief: Manganese Dioxide – BET Surface Area Nova 600 | 800 Series Application Reports
-
Material Brief: Microcrystalline Cellulose – BET Surface Area – Nova 600 Application Reports
-
Material Brief: Quartz – BET Surface Area Nova 600 | 800 Series Application Reports
-
Measuring Low Surface Area Materials Using Nova 600 | 800 Series Instruments Application Reports
-
Merging Pore Size Distributions from CO2 and N2 Adsorption Measurements Application Reports
-
Mesoporous Catalyst Supports Application Reports
-
Micropore Area and Volume by the t-Plot Method Application Reports
-
Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273 K Application Reports
Consumables & Accessories
Consumables & Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
TYPE B ROD, FOR 6 mm SHORT DIMPLE CELL
Nova 600 BET | 800 BET | 600 | 800
NOVA GAS INLET TUBE BET
Nova 600 BET | 800 BET | 600 | 800
NOVA GAS INLET TUBE
Nova 600 | 800
NOVA DESSICANT COLUMN
Nova 600 BET | 800 BET | 600 | 800
TYPE B SHORT CELL, 9 mm SM BULB
Nova 600 BET | 800 BET
TYPE C LONG CELL, 6 mm SM BULB
Nova 600 BET | 800 BET
TYPE B LONG CELL, 9 mm LG BULB
Nova 600 | 800
TYPE B SHORT CELL, 9 mm LG BULB
Nova 600 BET | 800 BET
TYPE B LONG CELL, 6 mm NO BULB
Nova 600 | 800
TYPE B SHORT CELL, 12 mm LG BULB
Nova 600 BET | 800 BET
TYPE B LONG CELL, 9 mm NO BULB
Nova 600 | 800
LEVEL SENSOR, CLS TYPE, CRYOGEN, SHORT
Nova 600 BET | 800 BET
TYPE B LONG CELL, 6 mm SM BULB
Nova 600 | 800
GAS SORPTION CALIBRATION CELL ASSEMBLY
Nova 600 BET | 800 BET | 600 | 800
TYPE B LONG CELL, 6 mm LG BULB
Nova 600 | 800
NON-ELUTRIATING PLUG, 12 mm
Nova 600 BET | 800 BET | 600 | 800
TYPE B LONG CELL, 9 mm SM BULB
Nova 600 | 800
TYPE B LONG CELL, 12 mm SM BULB
Nova 600 | 800
TYPE B LONG CELL, 12 mm LG BULB
Nova 600 | 800
DEWAR CRYOGEN LEVEL INDICATOR
Nova 600 BET | 800 BET | 600 | 800
TYPE B LONG CELL, 12 mm NO BULB
Nova 600 | 800
SURFACE AREA REFERENCE MATERIAL, 2001
Nova 600 BET | 800 BET | 600 | 800
2L Aluminum Dewar with handle
Nova 600 | 800
LEVEL SENSOR, CLS TYPE, CRYOGEN, LONG
Nova 600 | 800
TYPE B LONG CELL, 9 mm LG BULB, DIMPLE
Nova 600 | 800
REGULATOR (CGA)-CO2, 30 PSIG
Nova 600 BET | 800 BET | 600 | 800
O-RING, VITON 007, BROWN, PACK OF 2
Nova 600 BET | 800 BET | 600 | 800
O-RING, PFE 019, BLACK
Nova 600 BET | 800 BET
TYPE C SHORT CELL, 6 mm SM BULB
Nova 600 BET | 800 BET
TYPE B SHORT CELL, 6 mm SM BULB
Nova 600 BET | 800 BET
TYPE B SHORT CELL, 6 mm LG BULB
Nova 600 BET | 800 BET
TYPE B SHORT CELL, 9 mm LG BULB, DIMPLE
Nova 600 BET | 800 BET
TYPE B SHORT CELL, 6 mm NO BULB
Nova 600 BET | 800 BET
TYPE B LONG CELL, 9 mm NO BULB, QUARTZ
Nova 600 BET | 800 BET | 600 | 800
TYPE B ROD, FOR 6 mm LONG DIMPLE CELL
Nova 600 BET | 800 BET | 600 | 800
TYPE B ROD, FOR 9 mm LONG DIMPLE SM CELL
Nova 600 BET | 800 BET | 600 | 800
TYPE B LONG CELL, 6 mm SM BULB, DIMPLE
Nova 600 | 800
TYPE B ROD, FOR 9 mm SHORT DIMPLE LG
Nova 600 BET | 800 BET | 600 | 800
TYPE B LONG CELL, 9 mm SM BULB, DIMPLE
Nova 600 | 800
TYPE B ROD, FOR 9 mm SHORT DIMPLE SM
Nova 600 BET | 800 BET | 600 | 800
ETHERNET CABLE, 25 FEET
Nova 600 BET | 800 BET | 600 | 800
CELL-SEAL, OPENER 9MM
Nova 600 BET | 800 BET | 600 | 800
COMPRESSION NUT
Nova 600 BET | 800 BET | 600 | 800
TYPE B SHORT CELL, 9 mm SM BULB, DIMPLE
Nova 600 BET | 800 BET
TYPE B LONG CELL, 9 mm LG BULB, QUARTZ
Nova 600 BET | 800 BET | 600 | 800
TYPE B SHORT CELL, 12 mm SM BULB
Nova 600 BET | 800 BET
Nova X00 DEWAR COVER, 2 L, FOAM
Nova 600 BET | 800 BET | 600 | 800
1L ALUMINUM SHORT DEWAR WITH HANDLE
Nova 600 BET | 800 BET
P0 COLLAR, LARGE
Nova 600 BET | 800 BET | 600 | 800
BALANCE CELL HOLDER 6, 9, 12 mm CELL
Nova 600 BET | 800 BET | 600 | 800
TYPE B SHORT CELL, 12 mm NO BULB
Nova 600 BET | 800 BET
TYPE B SHORT CELL, 6 mm LG BULB, QUARTZ
Nova 600 BET | 800 BET | 600 | 800
TYPE B SHORT CELL, 12 mm LG BULB, QUARTZ
Nova 600 BET | 800 BET | 600 | 800
TYPE B ROD, FOR 12 mm SHORT CELL
Nova 600 BET | 800 BET | 600 | 800
CIRCULATING BATH, -20 C TO 150 C, 220 V
Nova 600 BET | 800 BET | 600 | 800
REGULATOR (CGA)-N2/HE/AR/KR, 25 PSIG
Nova 600 BET | 800 BET | 600 | 800
REGULATOR (CGA)-H2/CO/CH4, 60 PSIG
Nova 600 BET | 800 BET | 600 | 800
CONTROLLER/DATA MANAGEMENT MODULE (PC)
Nova 600 BET | 800 BET | 600 | 800
DEWAR, STORAGE, 5 L
Nova 600 BET | 800 BET | 600 | 800
DEWAR, STORAGE, 10 L
Nova 600 BET | 800 BET | 600 | 800
DEWAR, STORAGE, 30 L
Nova 600 BET | 800 BET | 600 | 800
WITHDRAWAL DEVICE, 30 L STORAGE DEWAR
Nova 600 BET | 800 BET | 600 | 800
ROLLER BASE, 30 L STORAGE DEWAR
Nova 600 BET | 800 BET | 600 | 800
CIRCULATING BATH, -20 C TO 150 C, 110 V
Nova 600 BET | 800 BET | 600 | 800
DEWAR, STORAGE, 50 L
Nova 600 BET | 800 BET | 600 | 800
ROLLER BASE, 50 L STORAGE DEWAR
Nova 600 BET | 800 BET | 600 | 800
WITHDRAWAL DEVICE, 50 L STORAGE DEWAR
Nova 600 BET | 800 BET | 600 | 800
Vacuum Pump, 100-120V
Nova 600 BET | 800 BET | 600 | 800
Vacuum Pump, 200-240V
Nova 600 BET | 800 BET | 600 | 800
NOVA X00, RECIRCULATING DEWAR KIT
Nova 600 BET | 800 BET | 600 | 800