High Vacuum Physisorption Analyzer:
Autosorb
- Accurate high vacuum physisorption analyses of surface area and micropores
- Advanced measurement routines made accessible with DoseWizard point selection and PowderProtect
- Up to three samples, three gases, and three temperatures can be measured simultaneously with independent analysis stations
Autosorb instruments are high vacuum physisorption and chemisorption analyzers designed for advanced measurements of BET surface area, active area, and pore size distributions. Independent analysis stations, exclusive TruZone active coolant control, and accessible Kaomi software let you meet your current measurement needs, while factory and field upgradeable options let you adapt to future ones. For your most important gas sorption measurements, the choice is clear: Absolutely Autosorb.
Key features
A gas sorption analyzer that’s absolutely accurate
- Get highly accurate physisorption measurements from relative pressures below 10-7 for nitrogen
- Leverage precise manifold temperature control between 35 °C and 50 °C
- Rely on TruZone active coolant level control for accurate data – even over lengthy analyses
- Achieve superior high vacuum performance (38 % better than previous generation instruments) with precision-machined manifolds and high-quality pneumatic valves
Independent stations ensure you’re absolutely agile
- Analyze up to three different samples with three different analysis gases at three different temperatures simultaneously with independent analysis stations and patented temperature control accessories
- Perform the most challenging physisorption measurements with the 90-hour Dewar
- Maximize your throughput with six integrated degassing stations
- Quickly swap to the 1100 °C furnace for advanced temperature programmed analyses, pulse titrations, or chemisorption isotherms
Intuitive software makes every analysis absolutely accessible
- Enjoy an updated and streamlined Kaomi software, which makes the whole measurement process easier than ever before
- Optimize measurement definition to suit your needs with DoseWizard’s new standard and advanced modes
- Keep downtime to a minimum with PowderProtect, which prevents accidental loss of powder in the instrument
Customization options keep you absolutely adaptable
- With 3 instruments and modular upgrades, the Autosorb adapts to the exact analysis requirements of your porous solids and catalysts
- As your research changes, the instrument’s physisorption and chemisorption features can be field upgraded to fit new materials and applications
- Go beyond standard measurements with enhanced chemical resistance, a built-in vapor source, thermal conductivity detector, or even a fully integrated mass spectrometer
Compliance and quality are absolutely assured
- Comply with 20+ ASTM, DIN, and ISO standards for catalyst characterization and the evaluation of porous solids.
- Get peace of mind with our 3-year warranty so you can avoid unforeseen costs
Technical specifications
Measurement Specifications
Autosorb 6100 | Autosorb 6200 | Autosorb 6300 | |
Measurement principle |
|
|
|
Analysis gas compatibility | |||
N2, Ar, Kr, CO2, H2, and other non-corrosive gases | Included | Included | Included |
CH4, C2H6, C3H8, other alkanes, C6H6, C8H10 | Included | Dependent on instrument configuration | Included |
NH3, C5H5N, C3H6O, and other reactive gases | N/A | Dependent on instrument configuration | Included |
Physisorption analysis stations | Number: 1, 2, or 3 Independence: Up to 3 gases at 3 analysis temperatures can be used concurrently, 1 analysis gas and temperature per station | ||
Chemisorption analysis stations | N/A | 1 | |
Independent p0 station | Yes (dedicated cell and transducer) | ||
Pressure |
| ||
BET surface area |
| ||
Pore size |
| ||
Active area | N/A |
| |
TruZone | Yes (active coolant level control) | ||
PowderProtect | Yes (prevents sample elutriation) | ||
Analysis dewar |
| ||
Analysis furnace | N/A |
| |
Sample preparation |
| ||
Additional capabilities | |||
Vapor source | Optional | Optional | Included |
CryoSync control | Optional | Optional | Optional |
TCD and loop injector | N/A | Optional | Included |
Mass spectrometer | N/A | Optional | Optional |
Kaomi software features
Autosorb 6100 | Autosorb 6200 | Autosorb 6300 | |
Instrument connection | Control up to 4 instruments from 1 PC | ||
DoseWizard |
| ||
Physisorption methods |
| ||
Chemisorption methods | N/A |
| |
Available languages | Chinese, English, French, German, Japanese, Korean, Portuguese, Spanish |
Technical Specifications
Autosorb 6100 | Autosorb 6200 | Autosorb 6300 | |
Dimensions (W x D x H) | 79.5 cm x 70.1 cm x 107.9 cm (31.3 in x 27.6 in x 42.5 in) dependent on instrument configuration | ||
Weight | 136.4 kg (300 lbs) dependent on instrument configuration | ||
Operating environment |
| ||
Gas distribution manifold elastomers | FKM | FKM or EPDM (dependent on instrument configuration) | PFE |
Analysis manifold construction | Vacuum-brazed manifold block in stainless steel | ||
Analysis manifold temperature |
| ||
Analysis manifold valves |
| ||
Pressure transducer (1550 Torr) -Analysis and degas |
| ||
Pressure transducer (10 Torr) – MP or XR |
| ||
Pressure transducer (1 Torr) – MP only |
| ||
Pressure transducer (0.1 Torr) – XR only |
| ||
Pirani vacuum gauge – Degas only |
| ||
Vacuum system |
| ||
Thermal conductivity detector (TCD) | N/A |
|
|
Gas ports |
|
|
|
Gas supply |
| ||
Air |
| ||
Electrical |
| ||
PC connection | Ethernet | ||
RoHS3 compliant | Yes | ||
CE / UKCA certified | Yes | ||
Indoor/outdoor use | For indoor use only |
Standards
ASTM
DIN
ISO
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Advantages of QSDFT for Pore Size Analysis of Carbons Application Reports
-
Graphene Characterization Application Reports
-
How to Appropriately Characterize the BET Area of a Microporous Material Application Reports
-
Improving the Structural Characterization of Zeolite with Argon Adsorption Application Reports
-
Material Brief: Activated Carbon - Cyclohexane - Autosorb 6100 Application Reports
-
Material Brief: Activated Carbon - Water Sorption - Autosorb 6100 Application Reports
-
Material Brief: MOF – Ar (87 K) & H2O (293 K) Adsorption – Autosorb 6100 Application Reports
-
Material Brief: Metal Powder - BET Surface Area - Autosorb 6100 Application Reports
-
Metal Organic Frameworks - Pore Size and Volume Measurement - Autosorb 6100 Application Reports
-
Micropore Area and Volume by the t-Plot Method Application Reports
-
Practical Methods to Prevent Sample Elutriation Application Reports
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
P0 COLLAR, AS6X00
Autosorb 6100 | 6200 | 6300
TYPE E LONG CELL, 12 mm, QUARTZ
Autosorb 6100 | 6200 | 6300
P0 CELL, STRAIGHT SM BULB, 323 mm LONG
Autosorb 6100 | 6200 | 6300
TYPE E ROD, FOR 12 mm LONG QUARTZ CELL
Autosorb 6100 | 6200 | 6300
TYPE A ROD, FOR 9 mm LONG CELL
Autosorb 6100 | 6200 | 6300
VOLUME / VAPOR CELL 13 cm3
Autosorb 6100 | 6200 | 6300
TYPE S CELL, LOOP INJECTOR, QUARTZ
Autosorb 6200 | 6300
FUNNEL, LONG STEM GLASS, 9/12 mm CELLS
Autosorb 6100 | 6200 | 6300
TYPE S ROD, LOOP INJECTOR, QUARTZ
Autosorb 6200 | 6300
DEWAR, 350 mL
Autosorb 6300
VACUUM GREASE .25 OUNCE
Autosorb 6100 | 6200 | 6300
TYPE S CELL, THIN FILM
Autosorb 6200 | 6300
TYPE A LONG CELL, 9 mm SM BULB
Autosorb 6100 | 6200 | 6300
TYPE A CELL, MONOLITH
Autosorb 6200 | 6300
AC INPUT CABLES
Autosorb 6100 | 6200 | 6300
TYPE A CELL, STOPCOCK
Autosorb 6200 | 6300
TYPE A LONG CELL, 9 mm CYL BULB
Autosorb 6100 | 6200 | 6300
GLASS TUBE, DEGAS COLD TRAP, 325 mm LONG
Autosorb 6100 | 6200 | 6300
TYPE F CELL, 6 mm MICRO
Autosorb 6100 | 6200 | 6300
O-RING, PFE 12 mm, BLACK
Autosorb 6300
AS6X00, RECIRCULATION DEWAR KIT
Autosorb 6100 | 6200 | 6300
O-RING, PFE 6 mm, BLACK
Autosorb 6300
FLOW DEGASSING KIT, AS6X00
Autosorb 6100 | 6200 | 6300
O-RING, PFE 9 mm, BLACK
Autosorb 6300
DEWAR FLASK, 3 L
Autosorb 6100 | 6200 | 6300
DEWAR, 2 L, WITH CLIP AND HANDLE
Autosorb 6100 | 6200 | 6300
ASIQ WIDE MOUTH DEWAR ASSEMBLY
Autosorb 6100 | 6200 | 6300
LEVEL SENSOR, CLS TYPE, CRYOGEN, OFFSET
Autosorb 6100 | 6200 | 6300
GAS INPUT 1 TO DEGAS CONNECTING LINE FOR AS6X00
Autosorb 6100 | 6200 | 6300
HEATING MANTLE, 7 PIN SOCKET, 24 VDC
Autosorb 6100 | 6200 | 6300
AS6X00 ANALYSIS DEWAR LID, 6 mm CELLS
Autosorb 6100 | 6200 | 6300
AS6X00 ANALYSIS DEWAR LID, 9 mm CELLS
Autosorb 6100 | 6200 | 6300
AS6X00 ANALYSIS DEWAR LID, 12 mm CELLS
Autosorb 6100 | 6200 | 6300
TYPE A CELL, STOPCOCK, LOWER
Autosorb 6200 | 6300
SAFETY COVER, AS6X00
Autosorb 6100 | 6200 | 6300
TYPE A CELL, STOPCOCK, UPPER
Autosorb 6200 | 6300
INPUT LINE, 5 FEET, STAINLESS STEEL MALE
Autosorb 6100 | 6200 | 6300
GAS INPUT LINE, 5 FEET, STAINLESS STEEL
Autosorb 6100 | 6200 | 6300
CRYOGEN MEASURING STICK
Autosorb 6100 | 6200 | 6300
O-RING, EPDM 12 mm, PURPLE, PACK OF 2
Autosorb 6200 | 6300
SAMPLE EXTRACTION HOOK
Autosorb 6100 | 6200 | 6300
BALANCE CELL HOLDER TYPE E LONG CELL
Autosorb 6100 | 6200 | 6300
FITTING PTC 6 mm TUBE X 1/4 NPT
Autosorb 6100 | 6200 | 6300
PUMP SILENCER G 1/8
Autosorb 6100 | 6200 | 6300
- Temperature range: -10 to +70 C
- Material of silencer insert: PE
- Pneumatic connection: G 1/8
TUBING POLYURETHANE OD 6 mm
Autosorb 6100 | 6200 | 6300
BULKHEAD SPANNER WRENCH
Autosorb 6100 | 6200 | 6300
O-RING, EPDM 6 mm, PURPLE, PACK OF 2
Autosorb 6200 | 6300
SAMPLE CELL ADAPTOR, 6 mm
Autosorb 6100
ChemBET REPLACEMENT FURNACE, 115 V
Autosorb 6200 | 6300
FURNACE CABLE
Autosorb 6200 | 6300
FURNACE HEAT SHIELD
Autosorb 6200 | 6300
O-RING, EPDM 9 mm, PURPLE, PACK OF 2
Autosorb 6200 | 6300
CALIBRATION SYRINGE, 0.50 mL
Autosorb 6200 | 6300
SYRINGE 2 INCH SIDE PORT .018X.008
Autosorb 6200 | 6300
CHEMSORB FURNACE POWER
Autosorb 6200 | 6300
TYPE B SHORT CELL, 9 mm SM BULB
Autosorb 6200 | 6300
SEPTUM [PACK OF 2]
Autosorb 6200 | 6300
THERMOCOUPLE, AS6X00 TCD
Autosorb 6300
TITRATION LOOP ADAPTER
Autosorb 6300
DEWAR LID, AS6X00 TCD COLD TRAP
Autosorb 6300
GAS INPUT LINE, 5 FEET, STAINLESS STEEL WITH QUICK CONNECT
Autosorb 6300
NUT & FERRULE, 1/8 INCH STAINLESS STEEL
Autosorb 6300
CryoSync ACCESSORY, AS6X00
Autosorb 6100 | 6200 | 6300
- Temperature stability better than +/-0.005K
- Analysis duration greater than 50 hours at 87K
- Full operating temperature range 82K to 115K
Cryostat Accessory for autosorb iQ:
CryoSync
Autosorb 6100
- Wide temperature range (82 K to >115 K)
- Precise temperature control (temp. stability < ±0.005 K S.D.)
- Perfect for argon isotherm measurements without using liquid argon or for multi-isotherm heat of adsorption experiments
- Runs for over 50 hours without refilling