This is a required field.
Invalid
Part number
Error in validation!

BET surface area analyzer:
Nova

  • media
  • media
  • media
  • media
  • +10
  • 360°
Model:
  • Optimize BET surface area, pore size, and volume analysis
  • Boost throughput with 4 analyses, and up to 8 degassing stations
  • Analyze 4 BETs in 20 minutes, 4 isotherms in 8 hours
  • Achieve 2 % reproducibility with ≥2 m2 measurement surface area
  • Simplify the analysis process with built-in profiles
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The Nova BET surface area analyzers have set a new benchmark in surface area and pore size analysis. 

Up to eight degassing stations plus up to four analysis stations let you degas samples while analyzing others. Analyze four 5-point BETs in approximately 20 minutes, with 2 % reproducibility. Automated degassing means no operator intervention is necessary.

Simple. Precise. Fast. Nova.

Key features

Integrated sample preparation simplifies your process

Eliminate the clutter, cost, and complexity of external degassing devices with eight integrated degassing stations and up to four analysis stations in one space-saving design. Prepare a range of samples within a vacuum or for flow degassing at temperatures up to 425 ºC. Degassing is software programable and linked with an individual sample ID, ensuring full traceability. These integrated degassing stations ensure that samples are fully prepared before analysis with the BET surface area analyzer.

Speed up your surface area and pore size analysis, and save costs

Utilize the Nova Mode. Use pre-calibrated sample cells – no need to measure void volumes before every analysis – and accelerate your analyses while maintaining a high level of measurement precision.

Benefit from the Nova Nitro ReGen concept: Channel the pure nitrogen gas evaporating from its Dewar to the instrument to use in experiments. This eliminates cylinders and simplifies setup while delivering accurate, repeatable BET results, and reduces environmental impact and lab costs. 

Nova Degassing Accessory can degas your samples using vacuum or flow degassing. This offers users flexibility and cost savings as they don’t have to buy multiple degassers.

TruZone – active coolant level control

With TruZone, create and maintain a small cold zone on the sample cell and maximize the measurement sensitivity of your surface area and pore size analyzer. Increase sensitivity when measuring gas molecules that are adsorbed by the sample results in exceptional measurement performance. Nova BET surface area analyzers deliver better than 2 % reproducibility with as low as 2 m2 total surface area in the sample cell. This best-in-class performance lets you measure materials with specific surface areas as low as 0.01 m²/g.

Suite of smart dosing algorithms for effortless method creation

Intelligent dosing algorithms, such as DoseWizard, VectorDose, and Initial Fill, simplify the creation of analysis profiles to accelerate analyses without sacrificing precision. In combination with the 20+ built-in analysis profiles for standardized methods like ASTM, ISO, USP, and DIN, our surface area and pore size analyzer delivers operational simplicity from start to finish.

A surface area and pore size analyzer with smart software

Combine instrument control and data processing with Kaomi for Nova. Set up and perform analyses, and process, report, and store data easily. Control up to four Nova BET surface area analyzers from one PC. 

21 CFR Part 11-compliant software

Enhance data integrity for the pharmaceutical industry with Kaomi for Nova 21 CFR Part 11 Software (user management, audit trail, customizable reporting, and electronic signature). 

This guarantees that your BET surface area analyzer meets FDA’s 21 CFR Part 11 requirements, ensuring complete data traceability and security, backed by a comprehensive pharma qualification and requalification package.

Specifications

 Nova 600 BETNova 800 BETNova 600Nova 800
Analysis specifications
Measurement principleVacuum Volumetric
Analysis gasesN2 onlyN2, Ar, CO2, and other non-corrosive gases
Analysis stations2424
Independent P0 stationYes
Relative pressure range (P/P0 )10-4 to 0.510-4 to 0.999
Pressure measurement accuracy0.1 % (of full scale) *
Pressure resolutionAbsolute : 1.2 x 10-4
Torr Relative : 1.5 x 10-7 P/P0
Lower specific surface area limitFrom 0.01 m2/g
Lower absolute surface area limitFrom 0.5 m2
Surface area reproducibility 2 %**
Pore size rangeN/A0.35 - 500 nm (Diameter)
(0.35 - 1.1 nm with CO2)
(1.1 - 500 nm with N2)
Minimum pore valueN/A1.2x10-8 cm3
TruzoneYes
PowerprotectYes
DosewizardYes
VectordoseYes
Analysis dewarVolume: 1 L
Duration: Up to 7 Hours
Volume: 2 L
Duration: Up to 40 Hours
Sample preparationIntegrated Degassing Stations : 4
Temperature Control: 2 Heating Zones, Ambient to 425 oC
Available Methods: Flow & Vacuum, Programable Multi-Step Heating Profiles
Physical specifications
Dimensions (DxWxH)44 cm x 63 cm x 84 cm
Weight63 kg
Operating environmentTemperature : 15 to 35 oC
Humidity : 20 to 80 % relative, non-condensing
Wetted partsStainless steel, Viton elastomers
GasPorts: 5 (3 Analysis, 1 Helium, 1 Degas/Backfill)
Purity: 99.999 % (He, N2)
Input Pressure: 8 to 10 PSIG
Vacuum connectionRotary Pump Exhaust Port, KF 16
Vacuum requirementsUltimate vacuum of 2.3 x 10-3 Torr
ElectricalSupply : AC 100~240 V AC , 50 / 60 Hz Consumption: 345 VA (Maximum)
Additional specifications
Display10-inch Touchscreen
PC connection Ethernet
Kaomi for Nova SoftwareInstrument Control: Up to 4 Instruments 
6 Languages: English, French, German, Japanese, Chinese, Spanish
Kaomi for Nova 21 CFR Part 11 SoftwareFeatures: User management, audit trail, customizable reporting, and electronic signature to enhance data integrity for use in the pharmaceutical industry
Pharma Qualification PackageYes
Pre-loaded analysis profiles20+ (ASTM, USP, DIN, ISO)
ROHS 3 compliantYes
CE certifiedYes

* Includes precision, linearity, and hysteresis s of the complete pressure measurement system
** Performed with BAM P115 certified reference material

Standards

Open all
Close all

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

Standards

Open all
Close all

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

Standards

Open all
Close all

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

Standards

Open all
Close all

ASTM

B922-10
C1069-09
C1274-12
D3663-20
D4222-03
D4365
D4641
D6556-17

ISO

9277
15901-2
18757

DIN

66134

US Pharmacopoeia (USP)

846 - Specific Surface Area

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

See more

Complementary products

Product Type
  • Accessory
Category
  • Miscellaneous

Enhancement option for Nova:
Degassing Accessory 

Compatible with :
Nova 800 | 600 | 800 BET | 600 BET
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 316060
Product details
  • Degas eight samples while eight are cooling
  • Heat up to 425 °C with the flexibility of two heating zones
  • Option to keep the heater on for faster turnaround time
  • Capable of performing vacuum and flow degassing
  • Keep track of degassing information, even on analysis reports
See more