Benchtop density meter:
DMA
- 4-digit measurements in 20 seconds
- Ultra-fast measurement mode maximizes throughout
- Best-in-class filling control provides reliable results
- 200+ conversion tables for quicker results
We’ve incorporated over five decades of experience developing market-leading benchtop density meters into our new generation of density meters. With best-in-class U-tube technology based on our patented Pulsed Excitation Method, our Next-Level Density Meters are the fastest, most intelligent benchtop density meters we’ve made to date.
20-second (4-digit) results give you high throughput. Compliance with a range of standards gives you peace of mind. There’s storage space for up to 10,000 measurements. And up to 6-digit accuracy gives you results you can rely on.
Now that’s taking it to the next level.
Glavne značajke

Fast and accurate benchtop density meters
- Get market-leading precision, repeatability, and reproducibility with our patented Pulsed Excitation Method
- Maximize throughput with an ultra-fast measurement mode
- Define limits for different samples and make pass/fail QC decisions right away
- 200+ pre-installed conversion tables show concentration values immediately
- Achieve excellent results for highly viscous samples with the best viscosity correction on the market
- Get reliable measurement results for high- and low-density samples as well as inhomogeneous, sedimenting, or particle-containing ones

High-tech features simplify your lab
- Know your samples are filled correctly with FillingCheck™, which even detects microbubbles, and U-ViewTM, which shows a zoomable image of the measuring cell
- Benefit from an automatic compensation of the U-tube’s aging effects and minimized drift over the lifetime of the instrument
- Use 30+ guided user workflows and five industry-specific profiles with predefined quantities and scales
- Streamline your data management with AP Connect

Guaranteed compliance gives you peace of mind
- Comply with ASTM D4052, D5002, D1250, ISO 12185 petroleum standards, and all relevant pharmacopeias
- Satisfy all major data integrity and traceability standards (e.g., 21 CFR Part 11)
- Ensure your results are traceable to the International System of Units (SI) with ISO 17025 calibration from our accredited lab
- Use our ISO 17034-certified reference material for density to ensure your instrument is perfectly calibrated

Modularity lets you conduct multiparameter analysis
- Connect your benchtop density meter to a range of Anton Paar measuring modules to forge a multiparameter system
- Measure all relevant QC parameters from the same sample under the same conditions
- Measure more than eight parameters at once

Automated processes for higher throughput
- Automate your filling, measuring, and cleaning process by choosing from seven different sample changers (optional)
- Ensure accurate results without operator influence
- Reduce contact with dangerous substances during filling with automated sample changers
Tehničke specifikacije
DMA 4101 | DMA 4501 | DMA 5001 | |
Measuring range | |||
Density | 0 g/cm³ to 3 g/cm³ | ||
Temperature | 0 °C to 100 °C (32 °F to 212 °F) | ||
Pressure | Up to 10 bar (145 psi) absolute pressure | ||
Accuracy | |||
Density | 0.0001 g/cm³ | 0.00005 g/cm³ (full range) 0.00001 g/cm³ (0 g/cm³ to 1 g/cm³, 15 °C to 20 °C) | 0.000005 g/cm³ |
Temperature | 0.03 °C (0.05 °F) | 0.02 °C (0.04 °F) (full range) 0.01 °C (0.02 °F) (15 °C to 20 °C) | 0.01 °C (0.02 °F) |
Repeatability | |||
Density | 0.00001 g/cm³ | 0.000005 g/cm³ | 0.000001 g/cm³ |
Temperature | 0.02 °C (0.04 °F) | 0.01 °C (0.02 °F) | 0.001 °C (0.002 °F) |
Reproducibility | |||
Density | 0.00005 g/cm³ | 0.00002 g/cm³ | 0.000005 g/cm³ |
Digital resolution | |||
Density | 0.0001 g/cm³ | 0.00001 g/cm³ | 0.000001 g/cm³ |
Features | |||
Power features | U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction | ||
Special functions | QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment at high viscosity (only DMA 5001 ) | ||
Automation | Automatic sample changers | ||
Modularity | pH, alcohol, CO2, O2, color, turbidity, refractive index | ||
Optional accessories | Aerosol adapter, heating attachment | ||
Technical data | |||
Typical measuring time/sample | 20 s | 30 s | 40 s |
Minimum sample volume | Approx. 1 mL | ||
Wetted materials | PTFE, borosilicate glass | ||
Dimensions (L x W x H) | 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in) | ||
Weight | 22.04 kg (48.6 lbs) | ||
Power supply | AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA | ||
Display | 10.1" TFT WXGA (1280 x 800 px); PCAP touchscreen | ||
Controls | Touchscreen, optional keyboard, mouse, and barcode reader | ||
Communication interfaces | 5 x USB, Ethernet, CAN, RS232 | ||
Internal storage | More than 10,000 measuring values with camera images |
Standardi
2020 Chinese Pharmacopoeia
ABNT
AOAC
ASBC
ASTM
CPTC
DIN
EBC
Europska unija
GB
HG
HM Revenue & Customs
IP
ISO
JIS
JJF
Japanese Pharmacopoeia (JP)
OIML
OIV
Pharmacopoeia Europe (Ph. Eur.)
QB
RANP
SH
TTB
U.S. Pharmacopoeia (USP)
Certificirana usluga servisa Anton Paar
- Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
- Kvalificirana podrška na vašem lokalnom jeziku
- Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
- Trogodišnje jamstvo
Dokumenti
-
DMA 4101/4501/5001 Brochure Brošure
-
Tank Terminals Overview Brochure Brošure
-
Vaccine Analysis Brochure Brošure
-
Vaccine Analysis Data Sheet Brošure
-
Alcohol Measurement Using Anton Paar Density Meters Izvješća o zahtjevu
-
Compensate your density results Izvješća o zahtjevu
-
Density Measurement of Infusion Solutions in Hospital Pharmacies Izvješća o zahtjevu
-
Density measurement gets the battery industry going Izvješća o zahtjevu
-
Density measurement of biodiesel Izvješća o zahtjevu
Potrošni materijal, Dodatni pribor, Softver & Referentni materijali
Potrošni materijal, Dodatni pribor, Softver & Referentni materijali
Dodatni pribor & Softver
Dodatni pribor & Softver
Da biste saznali možete li putem interneta kupovati sa svoje lokacije, provjerite dostupnost na mreži u nastavku.
Ako ne pronađete predmet koji vam je potreban, kontaktirajte svog prodajnog predstavnika tvrtke Anton Paar.

HOSE 2x4 SILICONE
DMA 4101 | 4501 | 5001

SYRINGE 5 mL LUER (WITHOUT SEAL)
DMA 4101 | 4501 | 5001

CABLE TIE HEAT-RESISTANT 100 pcs
DMA 4101 | 4501 | 5001

PROTECTION CAP, BLACK (SQUARE USB INTERFACE)
DMA 4501 | 5001

ACCESSORY KIT DMA HR01 SERIES/DMA 5000 M
DMA 4101 | 4501 | 5001

Protective cover DMA HR01 series
DMA 4101 | 4501 | 5001

Interface caps DMA HR01 series
DMA 4101 | 4501 | 5001

HOSE 3x5 VITON
DMA 4101 | 4501 | 5001

BOTTLE FOR RINSING LIQUID
DMA 4101 | 4501

GENDER CHANGER DB9F/DB9F
DMA 4101 | 4501 | 5001

"HOSE 300x3x2 PTFE ""AA"""
DMA 4101 | 4501 | 5001

SYRINGE HOLDER 5 ml FOR 5 ml PLASTIC SYRINGE
DMA 4101 | 4501 | 5001

HOSE 3x5 SILICONE
DMA 4101 | 4501 | 5001

HOSE 2x4 VITON
DMA 4101 | 4501 | 5001

PRINTER CONNECTION CABLE
DMA 4101 | 4501 | 5001

ADAPTER LUER 1/4" UNF
DMA 4101 | 4501 | 5001

ADAPTER UNF 1/4"-LUER MALE
DMA 4101 | 4501 | 5001

SYRINGES 2 ml LUER (1000 PCS)
DMA 4101 | 4501 | 5001

INJECTION ADAPTER UNF 1/4"
DMA 4101 | 4501 | 5001

INJECTION ADAPTER LUER
DMA 4101 | 4501 | 5001

INJECTION ADAPTER FITTING WITH METAL TUBE
DMA 4101 | 4501 | 5001

DENSITY STANDARD TRIMETHYLPENTANE
DMA 4101 | 4501 | 5001

SYRINGES 5 ml LUER (100 pcs.)
DMA 4101 | 4501 | 5001

MALE LUER PLUG
DMA 4101 | 4501 | 5001

ADAPTER LUER CONE
DMA 4101 | 4501 | 5001

SYRINGE 2 ml LUER (1 PCS)
DMA 4101 | 4501 | 5001

PRINTER PAPER 57x30 STANDARD
DMA 4101 | 4501 | 5001

HOSE 4X6 SILICONE
DMA 4101 | 4501 | 5001

SYRINGES 2 ml LUER (10 PCS)
DMA 4101 | 4501 | 5001

PRINTER PAPER FOR EPSON TM-U220
DMA 4101 | 4501 | 5001

RIBBON CARTRIDGE FOR EPSON PRINTER TM-U220
DMA 4101 | 4501 | 5001

DENSITY STANDARD ETHANOL IN WATER 40%ABV
DMA 4101 | 4501 | 5001

DENSITY STANDARD ETHANOL IN WATER 9%ABV
DMA 4101 | 4501 | 5001

DENSITY STANDARD "CAESIUM CHLORIDE" 10ML
DMA 4101 | 4501 | 5001

DENSITY STANDARD "OCEAN SEAWATER"
DMA 4101 | 4501 | 5001

COLOR ADJUSTMENT SET 3x ULTRA-PURE WATER 2x color standards (50 ml).
DMA 4101 | 4501 | 5001

HOSE CLAMP DMIN 5.8 DMAX 6.5
DMA 4101 | 4501 | 5001

SYRINGES 5 mL LUER-LOCK (100 PCS)
DMA 4101 | 4501 | 5001

SYRINGE 10 mL LUER-LOCK
DMA 4101 | 4501 | 5001

INJECTION ADAPTER LUER-LOCK
DMA 4101 | 4501 | 5001

INTERFACE CABLE DMA™-PC 9-POLE MALE / 9-POLE FEMALE
DMA 4101 | 4501 | 5001

ISO 17034-certified reference material:
Density standards
DMA 4101 | 4501 | 5001
- Market-leading uncertainty of 0.015 kg/m³ (ISO 17034)
- Application-specific density standards, available via webshop
- Online certificate with lifetime reference values guarantee
- Conformity with ISO requirements ISO 17025 and even ISO 17034
- Safety glass ampoule for zero contamination


DRYING CARTRIDGE
DMA 4101 | 4501 | 5001


KEYBOARD USA USB
DMA 4101 | 4501 | 5001


KEYBOARD GERMAN USB
DMA 4101 | 4501 | 5001



PROTECTING COVER FOR KEYBOARD
DMA 4101 | 4501 | 5001


PRINTER EPSON TM-U220D or B
DMA 4101 | 4501 | 5001

HEATING ATTACHMENT FOR DMA HR01 / M SERIES
DMA 4101 | 4501 | 5001

Lab execution software:
AP Connect Start
DMA 4101 | 4501 | 5001
- Now: 100 % discount at checkout!
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule

Lab execution software:
AP Connect Pharma (one-time license fee)
DMA 4101 | 4501 | 5001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Standard (one-time license fee)
DMA 4101 | 4501 | 5001
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Pharma (subscription license)
DMA 4101 | 4501 | 5001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab execution software:
AP Connect Standard (subscription license)
DMA 4101 | 4501 | 5001
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

AP DENSITY STANDARD DODECANE 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4101 | 4501 | 5001
- Density standard with low density (750 kg/m³)
- Organic liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD SODIUM BROMIDE 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4101 | 4501 | 5001
- Density standard with high density (1250 kg/m3)
- Aqueous liquid
- Measuring uncertainty: 0.03 kg/m³
- Specified temperature range: 15 °C – 25 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD GLUCOSE / WATER 10% 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4101 | 4501 | 5001
- Density standard with medium density (1040 kg/m3)
- Aqueous liquid
- Measuring uncertainty: 0.02 kg/m³
- Specified temperature range: 15 °C – 25 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD WATER 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4101 | 4501 | 5001
- Density standard with medium density (998 kg/m3)
- Aqueous liquid
- Suitable for density adjustments
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 35 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD OIL 30 cSt @ 40 °C 1x10 mL, WITH ISO 17034 CERTIFICATE
DMA 4101 | 4501 | 5001
- Density standard with low density (830 kg/m3)
- Organic liquid
- Viscous liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements