Dynamic Shear Rheometer:
SmartPave

  • +3
  • 360°
Model:
  • Rheometer for research and development of asphalt and bitumen
  • Illuminated sample area for perfect trimming results
  • Upgradeable for tests on solid mastic materials
  • Suitable for measurements of rubber-modified bitumen and at low temperature ranges down to -50 °C
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The dynamic shear rheometers (DSR) SmartPave 92 and SmartPave 303 enable the performance of precise measurements on asphalt binder and bitumen. Features such as Toolmaster, QuickConnect, a Peltier temperature device for dry sample heating, and step-by-step instructions for measuring procedures according to AASHTO T315, AASHTO T350, AASHTO TP101, ASTM D7175, ASTM D7405, and DIN EN 14770 guarantee convenient operation. For measurements according to AASHTO T316, ASTM D4402, and DIN EN 13302, both instruments can be equipped with a Peltier-controlled measurement chamber for concentric cylinder geometries.


Get Our Latest Bitumen Rheology Book
Interested in learning more about the flow and deformation behavior of bitumen in an easy, entertaining way? Then join Joe Flow and Samira Smart on the Bitumen Rheology Road.
Order now

Key features

Two models for the whole spectrum of rheological asphalt and bitumen testing

The well-established SmartPave dynamic shear rheometers analyze unmodified and modified asphalt binder and bitumen within a wide temperature range, either according to standards or by means of classic rheological methods. SmartPave 303 meets the highest measurement demands across the board. SmartPave 92 is designed especially for the demands of quality control and routine measurements in asphalt test labs.

RheoCompass software

RheoCompass is a navigation tool that provides both a complete overview and detailed insights. It contains numerous templates tailored specifically to using the dynamic shear rheometer in the asphalt industry. The predefined test procedures include step-by-step instructions for all test types as defined by AASHTO, ASTM, DIN EN, and FGSV. Templates are regularly updated to ensure you always comply with the latest version of your standard.

Unique accessories for easy handling

The unique temperature control unit of SmartPave 92 and SmartPave 303 is the first Peltier heating system with heating elements above and below the sample – combined with the widest temperature range. Both instruments also include Toolmaster. The only completely contact-free automatic tool recognition and configuration system for rheometers, it recognizes measuring systems and temperature control units as soon as they are connected to the rheometer, eliminating the need for manual data entry. 

Fully automatic temperature calibration

Temperature accuracy and stability are crucial in asphalt testing. Anton Paar offers fully automatic temperature calibration and verification routines via the RheoCompass software. The unique automatic calibration routine ensures temperature gradients <0.1 °C, tailored specifically for asphalt workflows using the SmartPave dynamic shear rheometer.

Upgrade your SmartPave DSR to a BBR

Enhance your SmartPave 303 or 92 with a specialized software solution from our cooperation partner, Pavement Systems LLC. Connect effortlessly to this external analysis software and unlock a range of features, including iCCL testing. This powerful surrogate method to BBR (AASHTO PP112) provides low-temperature PG grade, m-value, stiffness (S), and ΔTc results – all within 30 minutes. Learn more  about Pavement Systems and their analysis solutions.

Experienced experts on hand

Anton Paar’s worldwide service network ensures that an expert on your system is always nearby. Numerous installed instruments around the globe, an extensive application database, and cooperation with civil engineering institutes underscore that Anton Paar is the number one choice for answers to rheological questions about asphalt binder and bitumen.

Specifications

Technical DataUnitSmartPave 92SmartPave 303
Bearing design-Air, fine-pored carbon
Motor design-Electronically Commutated (EC) - Permanent Magnet Synchronous Motor
Displacement transducer design-High-resolution optical encoder
Normal force measurment design
(US Pat. 6167752,1996)
--360 ° capacitive sensor, non-contacting, fully integrated in bearing
Working mode-Combined Motor Transducer (CMT)
Minimum torque
(rotation)
nNm0.4 µNm5
Minimum torque
(oscillation)
nNm0.4 µNm1
Maximum torquemNm125215
Minimum angular deflection
(set value)
µrad10.5
Maximum angular deflection
(set value)
µrad
Minimum angular velocity[1]rad/s00
Maximum angular velocityrad/s157314
Maximum speed1/min15003000
Minimum speed (CSS/CSR)1/min 10-3 10-7
Minimum angular frequency[2]rad/s 10-4 10-7
Maximum angular frequencyrad/s6281256
Maximum frequency[3]HZ100200
Normal force rangeN--50 to 50
Normal force sensitivityN-0.001
Minimum gap size changeµm0.6250.0625
Dimensions (W x H x D)mm380 x 660 x 530453 x 725 x 673
Weightkg3348
Additional Device Features
Device display with remote control of software (decoupled from measuring sensor for mechanical and electromagnetic interference prevention)-YesYes
Direct strain/stress controller-YesYes
TruStrain™ (sample adaptive controller)-NoYes
TruRate™ (sample adaptive controller)-NoYes
Raw data (LAOS, waveform)-NoYes
Normal force profiles (set and read)-NoYes
Velocity profiles, tack, squeeze-NoYes
Automatic gap control/setting (AGC/AGS)-YesYes
Electronic trim lock for measuring geometry-YesYes
Toolmaster™
(measuring geometries and accessories, storing of zero-gap)
(US Pat. 7275419, 2004)
-YesYes
QuickConnect Coupling for measuring geometries
(one-hand operation, screwless)
-YesYes
Trimming mirror
(360° blind sample spot prevention)
-NoYes
Three-point support of device
(three robust feet for tool-free one hand alignment)
-YesYes
Three-point support for mounting of measuring cells
(wobble prevention, no misalignment after changing of cells)
-YesYes
Maximum temperature range[4]°C-50 to +400-160 to +1000
Virtually gradient-free temperature control
(horizontal,vertical)
-YesYes
Temperature gradient >0.1 °C according to AASHTO and ASTM-YesYes
CoolPeltier™ Peltier System with built-in cooling option that does not require additional accessories for counter cooling°C-5 to +200-5 to +200
Pressure CellbarNoup to 1000
Safe Gap™ normal force limiter during gap setting-YesNo
TruRay™ dimmable illumination of sample area-YesYes
RheoCompass Software
Asphalt standard operation procedures (SOP) with regular updates-YesYes
Auto Update via Network-OptionalOptional
Fully automatic temperature calibration-YesYes
Test and analysis designer-YesYes
Report designer
(with all test information for export and print)
-YesYes
Managed lab multiple clients and servers-OptionalOptional

1. In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode, depending on measuring point duration and sampling rate.
2. Theoretical value (duration per cycle = 2 years)
3. Higher frequencies are possible using multi-wave functionality (942 rad/s (150 Hz) or even higher, depending on measuring system and sample)
4. Depending on used temperature device

Standards

Open all
Close all

AASHTO

M320
M332
T315 "SHRP-Test"
T316
T350 "MSCR-Test"
TP101 "LAS-Test"
TP123 BYET

ASTM

D4402
D7175 "SHRP-Test"
D7405 "MSCR-Test"
D7552

DIN EN

13302
13702
14770
16659 "MSCR-Test"

FGSV

AL 720 BTSV
AL 721 Constant Shear Rate
AL 722 Temperature Sweep
AL 723 MSCR-Test

IS

73
15462

SATS

3208

AGPT

T125
T192
T194

GOST

33133
33137
R 58400.1
R 58400.6
R 58400.7
R 58400.10

Standards

Open all
Close all

AASHTO

M320
M332
T315 "SHRP-Test"
T316
T350 "MSCR-Test"
TP101 "LAS-Test"
TP123 BYET

ASTM

D4402
D7175 "SHRP-Test"
D7405 "MSCR-Test"
D7552

DIN EN

13302
13702
14770
16659 "MSCR-Test"

FGSV

AL 720 BTSV
AL 721 Constant Shear Rate
AL 722 Temperature Sweep
AL 723 MSCR-Test

IS

73
15462

SATS

3208

AGPT

T125
T192
T194

GOST

33133
33137
R 58400.1
R 58400.6
R 58400.7
R 58400.10

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

See more

Complementary products

Product Type
  • Accessory
Category
  • Temperature Control

Temperature Control for MCR:
Peltier Systems 

Compatible with :
SmartPave 92 | 303
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Effective and convenient heating and cooling
  • Air cooled Peltier hood and plate; sustainable and cost efficient
  • Temperature control with minimized temperature gradients from -50 °C to +220 °C
  • Modular system for combination with rheo-optics accessories
  • For cone-plate, parallel-plate, and cylinder measuring systems
See more