Dynamic shear rheometer:
SmartPave
- The asphalt rheometer for quality control and routine measurements of asphalt and bitumen
- Illuminated sample area for perfect trimming results
- Air-cooled Cool Peltier temperature accessory makes thermostats obsolete
- The asphalt rheometer for research and development of asphalt and bitumen
- Features like TruGap™ (automatic gap measurement) and T-Ready™ (automatic sample temperature detection ) included
- Suitable also for measurements of rubber-modified bitumen and at low-temperatures of down to -30 °C
upon request
The dynamic shear rheometers (DSR) SmartPave 92 and SmartPave 102 allow precise measurements on asphalt binder and bitumen. Features such as Toolmaster™, QuickConnect, a Peltier temperature device for dry sample heating, and step-by-step instructions for measuring procedures according to AASHTO T315, AASHTO T350, AASHTO TP101, ASTM D7175, ASTM D7405, and DIN EN 14770 guarantee the most convenient operation. For measurements according to AASHTO T316, ASTM D4402, and DIN EN 13302 both instruments can be equipped with a Peltier-temperature-controlled measurement chamber for concentric cylinder geometries.
Key features

Two models to cover the whole spectrum of rheological asphalt and bitumen testing
The well-established SmartPave dynamic shear rheometers are able to analyze unmodified as well as modified asphalt binder and bitumen in a wide temperature range, either according to standards or with classic rheological methods. While SmartPave 102 is the instrument which meets the highest measurement demands, SmartPave 92 is designed especially for the demands of quality control and routine measurements in asphalt test labs.

The RheoCompass™ software: new paths for asphalt and bitumen testing
RheoCompass™ is a navigation tool that gives you the complete overview as well as the exact insights you require. It contains numerous templates that are tailored specifically to the needs of the asphalt industry. The predefined test procedures contain step-by-step instructions for all test types as defined by AASHTO, ASTM, DIN EN, and FGSV.

Unique accessories for easy handling
SmartPave 92’s and SmartPave 102’s unique temperature control unit is the first Peltier heating system with heating elements above and below the sample. Furthermore, the instruments feature Toolmaster™ – the only completely contact-free automatic tool recognition and configuration system for rheometers. It recognizes measuring systems and temperature control units as soon as they are connected to the rheometer so you don’t need to enter any data manually.

Fully automatic temperature calibration
Anton Paar offers fully automatic temperature calibration and verification routines in the RheoCompass™ software. Temperature accuracy and stability are crucial in asphalt testing. The unique automatic temperature calibration routine ensures temperature gradients <0.1 °C.

Experienced experts close to you
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. Numerous installed instruments around the globe, an extensive application database, and cooperation with civil engineering institutes confirm that Anton Paar is the first choice for answering any rheological question on your asphalt binder and bitumen you might have.
Technical specifications
Technical Data | SmartPave 92 | SmartPave 102 |
Bearing | Air | Air |
---|---|---|
EC motor | Yes | Yes |
Maximum torque | 125 mNm | 200 mNm |
Min. torque (rotation) | 1 µNm | 5 nNm |
Min. torque (oscillation) | 1 µNm | 2 nNm |
Torque resolution | 100 nNm | 0.5 nNm |
Angular deflection (set value) | 1 µrad to ∞ µrad | 1 µrad to ∞ µrad |
Angular resolution | 614 nrad | 10 nrad |
Min. angular velocity | 10-4 rad/s | 10-8 rad/s |
Max. angular velocity | 157 rad/s | 314 rad/s |
Max. speed | 1500 1/min | 3000 1/min |
Min. angular frequency | 10-4 rad/s | 10-7 rad/s |
Max. angular frequency | 628 rad/s | 628 rad/s |
Normal force range | – | 0.01 N to 50 N |
Normal force resolution | – | 1 mN |
Max. temperature range | -5 °C to +200 °C | -40 °C to +200 °C |
Toolmaster™ | Yes | Yes |
QuickConnect | Yes | Yes |
Automatic gap setting (AGC/AGS) | Yes | Yes |
TruGap™ (innovative system for measuring the gap) | No | Yes |
T-Ready™ (automatically detects and transmits the sample temperature) | No | Yes |
Normal force and velocity profiles, tack, squeeze | No | Yes |
Applications | ||
AASHTO T315 / ASTM D7175 (SHRP-Test/SuperPave PG) | Yes | Yes |
AASHTO T316 / ASTM D4402 DIN EN 13302 & 13702 (Rotational Viscosity) | Yes | Yes |
AASHTO T350 / ASTM D7405 DIN EN 16659 (MSCR-Test) | Yes | Yes |
AASHTO TP101-UL (LAS-Test) | No | Yes |
FGSV AL 720 BTSV FGSV AL 721 (Constant Shear Rate) FGSV AL 722 (Temperature Sweep) FGSV AL 723 (MSCR-Test) | Yes | Yes |
Master Curves | Optional | Yes |
Measurement of rubber-modified bitumen | No | Yes |
Low-temperature measurements -30°C (parallel plate) | No | Yes |
Low-temperature measurements -20°C (torsion) | No | Yes |
Standards
AASHTO
AGPT
ASTM
DIN EN
FGSV
GOST
IS
SATS
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
To find out if you can purchase online from your location, check the online availability below.
If you do not find the item you require, please contact your Anton Paar sales representative.

Disposible Measuringcup C-CC27/D/AL

Filterelement for Feinstfilter 10661

Filterelement for Fine Filter 10660

Silicone Mold 18mm for Asphalt Binder

Silicone Mold 8mm for Asphalt Binder

Viscosity standard AP N26 C (500 ml)

Viscosity standard AP N415 H (500 ml)

Viscosity standard AP N7.5 M (500 ml)

Viscosity standard AP S3 L (500 ml)

Inset I-PP08/Cu/Cx

Inset I-PP25/Cu/Cx

Meas. Cylinder B-CC27

Measuring Plate PP08/PE

Measuring Plate PP08/SP

Measuring Plate PP25/PE

Measuring Plate PP25/SP

Temperature control for MCR:
Peltier systems
- Effective and convenient heating and cooling
- Patented temperature control with minimized temperature gradients from -40 °C to 200 °C
- Modular system for combination with Rheo-Optics accessories
- For cone-plate, parallel-plate, and cylinder measuring systems