SAXS/WAXS/GISAXS/USAXS/RheoSAXS Laboratory Beamline:
SAXSpoint 5.0

  • media
  • +5
  • Compact 3.6 m x 0.9 m footprint
  • Investigate nanomaterials (e.g., size, shape, internal structure) 
  • Non-destructive measurement technology
  • Measure samples directly in their native biological environment
  • Optimize measurements for the synchrotron
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN
If you can't find your country in the list get a quote

SAXSpoint 5.0 is the ultimate SAXS/WAXS/GISAXS/USAXS/RheoSAXS laboratory beamline with synchrotron detector technology for the highest resolution in a compact system. Anton Paar’s brilliant SAXS system resolves nanostructures up to 620 nm. SAXSpoint 5.0 offers flexible analysis of almost any material under ambient and non-ambient conditions. A number of additional optional features equip SAXSpoint 5.0 for future applications up to the micrometer range (USAXS). Easily perform non-destructive investigations of material properties via powerful software packages that enable automatic operation and data analysis.

Key features

Excellent data quality with short measurement times

Excellent data quality with short measurement times

SAXSpoint 5.0 employs a brilliant X-ray beam with high spectral purity and scatterless beam collimation. Equipped with powerful microsource or MetalJet X-ray sources and high-performance optics, it delivers excellent results within exceptionally short exposure times. Combined with the latest hybrid photon-counting (HPC) detectors, it ensures high-quality SAXS/WAXS/GISAXS/USAXS/RheoSAXS results for the analysis of your nanostructured materials. Excellent resolution is reached with this brilliant setup, resolving structures up to 620 nm (USAXS up to the µm range) with the most compact system size (3.6 x 0.9 m) of its class.

Obtain SAXS and WAXS data in one go

Obtain SAXS and WAXS data in one go

SAXSpoint 5.0 features a moving detector, Slidemaster, which enables completely automatic X-ray scattering studies over a very wide q-range. Obtain SAXS and WAXS data in one go without additional realignment of the system. Choose your optimum q-range from the highest SAXS resolution to a wide WAXS regime for every experiment by just moving the detector. 
SAXSpoint 5.0 provides automatic beamstop selection and positioning for your measurement. As it integrates the latest EIGER2 R detectors, windowless and beamstop-less measurements can be performed.

SAXS analysis challenging? Working with SAXSpoint 5.0 isn’t

SAXS analysis challenging? Working with SAXSpoint 5.0 isn’t

Automating routine tasks to accelerate the way to measurement is standard in the SAXSpoint 5.0 lab system. SAXSpoint 5.0 is equipped with Stagemaster, which automatically aligns all X-ray components and sample stages, recognizes which stage is implemented, and configures the system accordingly. This gives you the best possible result for your measurement setup. Automate your sample throughput with the low-volume autosampler for liquids for up to 192 sample with a temperature-controlled well plate compartment for sample cooling and heating during storage.

Choose stages: One system for all experimental conditions

Choose stages: One system for all experimental conditions

Almost any nanostructured material can be analyzed with various sample stages from Anton Paar. Switching between different sample stages is easy and fast with TrueFocus, which ensures automatic alignment of all components. 

  • TCStage sample-holder units: temperature-controlled studies from -150 °C to 600 °C
  • Humidity Stage: analysis under defined RH and temperature
  • GISAXS/GIXD stage: studies of nanostructured surfaces and thin films
  • Heated/cooled sampler: automated studies with temperature-controlled samplers 
  • Tensile stage: analysis of nanostructured fibers under defined mechanical load
  • RheoSAXS module: combined full rheological and nanostructural investigations in one go 
Powerful control and data analysis software

Powerful control and data analysis software

SAXS data analysis is complex. The intuitive SAXSdrive™ and SAXSanalysis™ software solutions are the easiest way to obtain results. They support automated routine steps, like measurement setup and alignment, and comprehensive data analysis. Set up serial measurements, benefit from automated sampling, temperature scans, and time-dependent studies, and analyze your 1D and 2D data sets using customizable templates. Determination of parameters like radius of gyration (RG), particle size, Porod constant, specific surface, Kratky plot, etc. is standard in SAXSanalysis™. 

Technical specifications

X-ray source
  • Primux 100 micro microfocus X-ray source (Cu, Mo; other target materials on request)
  • Optional dual microfocus X-ray sources (Cu and Mo; other target materials on request)
  • High-performance Ga/In MetalJet source
X-ray optics and collimation
  • Custom-designed ASTIX optics (fully evacuated)
  • Automated scatterless beam collimation (fully evacuated)
Sample stages and autosamplers
  • TCStage temperature-controlled stages (-150 °C to 600 °C)
  • GISAXS stage with heating/cooling option (-150 °C to 500 °C)
  • Tensile Stage with heating/cooling option (-150 °C to 350 °C)
  • Humidity Stage
  • Temperature-controlled autosamplers for multiple samples(-150 °C to 350 °C)
  • RheoSAXS module
  • Shear Cell
  • ASX autosamplers for up to 192 liquid samples

Customized solutions available on request

Special featuresSlidemaster: moving detector (translation in X,Y,Z)
TrueFocus: automatic self-alignment
TrueSWAXS: continuous and simultaneous SWAXS studies
Stagemaster: XYZ stage with auto-recognition of sample stages
Optional high-resolution WAXS module
Optional high-performance optics providing an X-ray flux of >4 x 10 8 ph/s
Temperature range-150 °C to +600 °C
Temperature accuracy±0.1 °C
AtmosphereVacuum, air, inert gas, humidity (reactive gases on request)
Sample holders
  • Quartz capillary for liquids
  • Low-parasitics SiN cell
  • Sample holder for solids
  • PasteCell for viscous and powder samples
  • RotorCell for sample spinning
  • High-pressure cell
  • μ-Cell for small sample volumes
  • FlowCell and TubeCell for automation
  • Holders for multiple samples
  • Multicuvette holder
  • UV-Vis cell
  • Osmotic cell

Customized solutions available on request please contact us

Detectors2D EIGER2 R and PILATUS3 R series HPC detectors
High-resolution WAXS module (EIGER2 R series)
Accessible q-range0.01 nm-1 to 49.3 nm-1 (main detector)
Software
  • SAXSdrive™ measurement and acquisition software
  • SAXSanalysis™ data processing and analysis software
  • PCG advanced data interpretation software
Footprint
  • 3.6 m x 0.9 m (Microsource version, L x W)
  • 4.5 m x 0.9 m (MetalJet version, L x W)

Standards

Open all
Close all

ISO

17867 Particle size analysis – Small angle X-ray scattering (SAXS)
20804 Determination of the specific surface area of porous and particulate systems by small-angle X-ray scattering (SAXS)

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Product
Your choice: Reset all filters

No results found!

See more

Consumables & Accessories

Consumables & Accessories

Accessories

Accessories

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

QUARTZ CUVETTE 1 mm FOR TCS Sample holder with 1 mm quartz capillary for measurements of

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 10666
Product details
liquid samples. Can be used on all TCS and TCStage sample holder units as well as with the Heated Sampler and Heated/Cooled Sampler.

Temperature-Controlled Sample Stages:
TCStage 

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Temperature-controlled sample stages for single samples
  • Dedicated sample holders for liquids, solids, pastes, and gels
  • Special sample holders e.g. for sample spinning, under pressure, and for disposable capillaries
  • Temperature range from -150 °C to +600 °C 

More info

Heated Sampler

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Temperature-controlled sample stages for Anton Paar’s SAXSpoint systems
  • Automatic scans on up to 20 solid, liquid, and paste/gel-like samples
  • Heated/Cooled Sampler: from -10 °C to 120 °C
  • Heated Sampler 2.0: from -150 °C to 350 °C 

More info

Bonse-Hart USAXS Camera:
USAXS Module 

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Automatic USAXS, SAXS, and WAXS studies using a fully motorized experimental setup
  • Probing structures from the nanometer to the micrometer level
  • Simultaneous and precise (± 0.1 °C) sample temperature control

More info

(Bio-)SAXS Autosampler for Liquids:
Low-Volume Autosampler 

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • High-throughput autosampler for liquid nanoparticle and biological samples (up to 192 in one run)
  • Optimized setup requiring minimal sample volume (≤ 5 μL)
  • Modular design enabling easy switch-over to standard SAXS sample stages

More info

Autosampler:
ASX 

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • High sample throughput of up to 192 samples from 96 well plates
  • High-precision injection down to 10 µL sample volume
  • Compatible with all Anton Paar flow-through cells: Flow Cell, Tube Cell, SiN Cell
  • Minimal bench space required

More info

GISAXS Stage 2.0

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Investigation of nanostructured surfaces and thin film samples
  • Ideal for mesoporous thin films, surface-deposited nanoparticles, metal deposits on oxide surfaces, soft matter systems, and biological materials attached to surfaces
  • Samples can be tilted and rotated

More info

Tensile Stage 2.0

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • The only commercially available stage specially designed for in-situ SWAXS studies of stress/strain phenomena
  • For investigating fibers, foils, and thin films
  • Studies at forces between 0.01 N and 600 N
  • Temperature range from -150 °C to +350 °C

More info

Humidity Stage

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • For temperature- and humidity-dependent SAXS and WAXS studies of nanostructures
  • Ideal for investigating the influence of temperature and humidity on powders and thin films
  • Studies in vacuum, air, and inert gas from 10 °C up to 110 °C

More info

Combined Rheology and SAXS Setup:
RheoSAXS Module 

Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Study structural and rheological properties simultaneously
  • Measure parallel or perpendicular to flow direction
  • All existing SAXSpoint instruments can be upgraded with this module

More info