This is a required field.
Invalid
Part number
Error in validation!

SAXS/WAXS System:
SAXSpoint 700

  • Dual-monitor setup showing SAXS data analysis software from the Anton Paar SAXSpoint 700 system, with 2D scattering pattern and particle size distribution.
  • media
  • +7
  • Flagship system: Groundbreaking research at an unbeatable price
  • Unique measurement chamber: Endless experimental possibilities
  • Brilliant results, thanks to best-in-class beam delivery system
  • Accelerate research and ensure quality with automation
  • Obtain meaningful results thanks to powerful analysis software

SAXSpoint 700 is the ultimate SAXS/WAXS/GISAXS/USAXS/RheoSAXS laboratory beamline with synchrotron detector technology for the highest resolution in a compact system. Anton Paar’s brilliant SAXS system resolves nanostructures up to 620 nm. SAXSpoint 700 offers flexible analysis of almost any material under ambient, non-ambient conditions - even air. With its spacious measurement chamber, this SAXS system provides endless experimental possibilities at a unique price-performance ratio. Easily perform non-destructive investigations of material properties via powerful software packages that enable automatic operation and data analysis. A wide range of features equip SAXSpoint 700 for future applications.

Key features

A SAXS System with Endless Experimental Possibilities

SAXSpoint 700’s new and improved measurement chamber opens up endless possibilities with its size, a wealth of sample environments, and customization for specific experiments. Tailor your SAXS system to your requirements so that you can take on nanostructured material analysis with ease. Seamlessly switch between different sample stages thanks to the SAXSdrive™ software and automatic stage recognition, which ensures automatic alignment of all components. Cover an impressive temperature range of -150 °C to 500 °C, combine full rheological and nanostructural investigations with the RheoSAXS module, and conduct automated studies with temperature-controlled samplers - even in air.

Pure brilliance

Take on difficult samples with the help of the best-in-class beam delivery system. Thanks to a brilliant X-ray beam with the highest spectral purity (>99.9 % Cu Kα) and scatterless beam collimation, users are guaranteed synchrotron-like data quality (including SAXS/WAXS/GISAXS/USAXS/RheoSAXS) with minimum effort and the shortest exposure times.
This SAXS system, with its brilliant setup and industry-leading optical system, enables the resolution of structures up to 620 nm (USAXS up to the µm range), at the most compact system size (3.6 m x 0.9 m).

SAXS and WAXS in one go

Obtain SAXS and WAXS data in one go with Slidemaster. Without any additional realignment of the SAXS system necessary, save time by cutting out any setup steps between measurements. Simply choose your optimum q-range from the highest SAXS resolution to a wide WAXS regime for every experiment. What's more, due to the automatic beamstop selection, another step is taken out of the whole process, saving you time and effort. With EIGER2 R detectors even fully beamstop-less measurements are possible.

Powerful software

The SAXSdrive™ software, with automated routine steps, such as temperature scans and time-dependent studies allows you to perform experiments while focusing on more important tasks. 

Analyze your SAXS data sets with SAXSanalysis™, which combines automated data processing with advanced analysis routines. With just one click, you can obtain key parameters such as radius of gyration (Rg), pair-distance distribution function (p(r)), particle size, Porod constant, specific surface, and Guinier and Kratky plots. Export data into all relevant formats for further analysis, and meet industry standards and norms, e.g., ISO 20804.

A life-long software update policy ensures that customers fully benefit from future innovation.

Dual-monitor setup showing SAXS data analysis software from the Anton Paar SAXSpoint 700 system, with 2D scattering pattern and particle size distribution.

Support when you need it

Get the most back from your investment with Anton Paar's standard three-year warranty. Maximize your SAXS system’s uptime with immediate responses to service requests. Should you need application support, there is always an application expert nearby in over 40 subsidiaries around the globe.

Specifications

X-ray sourcePrimux 100 micro microfocus X-ray source (Cu, Mo; other target materials on request)
Optional dual microfocus X-ray sources (Cu and Mo; other target materials on request)
High-performance Ga/In MetalJet source
X-ray optics and collimation
  • Custom-designed AXO ASTIX/ASTIX++ optics (fully evacuated)
  • Automated scatterless beam collimation (fully evacuated)
Sample stages and autosamplers
  • TCStage temperature-controlled stages (-150 °C to +500 °C)
  • GISAXS Stage with heating/cooling option (-150 °C to +500 °C)
  • Tensile Stage with heating/cooling option (-150 °C to +350 °C)
  • USAXS Stage with heating/cooling option (-10 °C to +350 °C)
  • Humidity Stage
  • Temperature-controlled autosamplers for multiple samples (-150 °C to +350 °C)
  • RheoSAXS module
  • Battery Cell
  • Shear Cell
  • ASX autosamplers for up to 192 liquid samples

Customized solutions available on request

Special features
  • Slidemaster: moving detector (translation in X,Y,Z)
  • TrueFocus: automatic self-alignment
  • TrueSWAXS: continuous and simultaneous SWAXS studies
  • Stagemaster: XYZ stage with auto-recognition of sample stages
  • Optional high-resolution WAXS module
  • Optional high-performance ASTIX++ optics enabling a flux of > 6 x 108 ph/s
Temperature range-150 °C to +500 °C
Temperature accuracy±0.1 °C
AtmosphereVacuum, air, inert gas, humidity (reactive gases on request)
Sample holders
  • Quartz capillary for liquids
  • Low-parasitics SiN cell
  • Sample holder for solids
  • PasteCell for viscous and powder samples
  • RotorCell for sample spinning
  • High-pressure cell
  • μ-Cell for small sample volumes
  • FlowCell and TubeCell for automation
  • Holders for multiple samples
  • Multicuvette holder
  • UV-Vis cell
  • Osmotic cell

Customized solutions available on request please contact us

Detectors2D EIGER2 R and PILATUS4 R series HPC detectors
High-resolution WAXS module (EIGER2 R series)
Accessible q-range0.01 nm-1 to 49.3 nm-1 (main detector)
Software
  • SAXSdrive™ measurement and acquisition software
  • SAXSanalysis™ data processing and analysis software
Footprint3.6 m x 0.9 m (Microsource version, L x W)
4.5 m x 0.9 m (MetalJet version, L x W)

Standards

Open all
Close all

ISO

17867 Particle size analysis – Small angle X-ray scattering (SAXS)
20804 Determination of the specific surface area of porous and particulate systems by small-angle X-ray scattering (SAXS)

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

See more

Similar products

Complementary products

Product Type
  • Accessory
  • Consumable
  • Software
Category
  • Autosampler
  • Cell
  • Cuvette
  • Filter
  • Laboratory Software
  • Miscellaneous
  • RheoSAXS Module
  • Stage
  • USAXS Module

SPARE PARTS LIQUID HOLDER 2x2 VITON

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 325169
Product details

Spare parts set for the 2x2 liquid holder including 48 O-Rings, 50 Kapton foils and 4 spare screws.

Accessories for SAXSpoint 700 and SAXSpoint 500:
Battery Cell 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Stage for operando battery measurements
  • Wide application range
  • Effective cell design for quality outputs

More info

Accessory for SAXSpoint 700 and SAXSpoint 500:
GISAXS Stage 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Analysis of surface nanostructure of thin-film samples
  • Samples can be tilted and rotated
  • Conduct temperature-dependent studies up to 500 °C
  • Combine GISAXS with Anton Paar’s Humidity Cell
     

More info

Accessory for SAXSpoint 700:
Humidity Stage 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Measurement at 5 % to 95 % relative humidity
  • Temperature from +10 °C to +60 °C
  • Precise temperature and humidity control
  • Measurement in both transmission or reflection geometry

More info

Accessories for SAXSpoint 700 and SAXSpoint 500:
Temperature-controlled stages for multiple samples 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Temperature range of -150 °C to + 350 °C
  • Analysis of multiple solids, gels, pastes, and liquids
  • High degree of temperature accuracy
  • Quick heating/cooling rates
  • Automated multi-sample measurement of up to 20 samples

More info

Dual-monitor setup with SAXSanalysis Pro software displaying scattering curves, size distribution analysis, and detector control interface.

SAXS Software:
SAXSanalysis Pro 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 396657
Product details
  • Automated data processing of SAXS/WAXS measurements
  • Determination of particle size, specific surface area, and more
  • Scattering data in absolute numbers without reference sample
  • Automatic data export routines to common file formats

More info

SPARE PARTS SAXSess HOUSING

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 15194

PASTECELL WINDOWS FOR 120 °C (100 Pcs.)

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 25916
Product details

100 spare windows (colorless, operating temperature < 120 °C).

SPARE PARTS PASTECELL (120 °C)

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 46869
Product details

Spare parts for the Pastecell, including:
- 2 Pcs. O-ring sets
- 10 Pcs. windows for < 120 °C

SPARE PARTS QUARTZ CUVETTE

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 49738
Product details

O-rings and PTFE gaskets

SPARE PARTS µ-CELL

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 49740
Product details

O-rings and filling adapter

WATERFILTER R50 FOR SEALED TUBE GENERATOR COOLING CIRCUIT

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 87110

WARNING LAMP "X-RAY ON" FOR ID3003 GENERATOR

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 89003

SPARE PEEK FERRULES AND NUTS FOR ASX(-c) AUTOSAMPLER

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 104971

SPARE PARTS PASTECELL N

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 174079
Product details

Spare parts for the Pastecell N, including:
- 4 Pcs. spare sealings
- 10 Pcs. window sets for < 120 °C
- 10 Pcs. window sets for < 300 °C
- 6 Pcs. spare inlets

PASTECELL N WINDOWS FOR 120 °C (30 Pcs.)

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 174081
Product details

30 Pcs. spare window sets (colorless, operating temperature < 120 °C).

PASTECELL N WINDOWS FOR 300 °C (30 Pcs.)

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 174082
Product details

30 Pcs. spare window sets (orange, operating temperature < 300 °C).

SPARE PARTS SAXSpoint 5.0 INSTRUMENT

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 235869
Product details

O-rings for SAXSpoint 5.0 instrument chamber, collimation and SlideMaster detector modules.

Heated Sampler

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Temperature-controlled sample stages for Anton Paar’s SAXSpoint systems
  • Automatic scans on up to 20 solid, liquid, and paste/gel-like samples
  • Heated/Cooled Sampler: from -10 °C to 120 °C
  • Heated Sampler 2.0: from -150 °C to 350 °C 

More info

Accessory for SAXSpoint 700:
USAXS Module 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Automatic USAXS, SAXS, and WAXS studies via your SAXS instrumentation
  • Fully motorized experimental setup
  • Probing of structures from the nanometer to the micrometer level
  • Simultaneous, precise (± 0.1 °C) sample temperature control

More info

Autosampler:
ASX 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • High sample throughput of up to 192 samples from 96 well plates
  • High-precision injection down to 10 µL sample volume
  • Compatible with all Anton Paar flow-through cells: Flow Cell, Tube Cell, SiN Cell
  • Minimal bench space required

More info

Tensile Stage 2.0

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • The only commercially available stage specially designed for in-situ SWAXS studies of stress/strain phenomena
  • For investigating fibers, foils, and thin films
  • Studies at forces between 0.01 N and 600 N
  • Temperature range from -150 °C to +350 °C

More info

QUARTZ CUVETTE 1 mm FOR TCS

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number : 10666
Product details

Sample holder with 1 mm quartz capillary for measurements of liquid samples. Can be used on all TCS and TCStage sample holder units as well as with the Heated Sampler and Heated/Cooled Sampler.

Accessory for SAXSpoint 700:
RheoSAXS Module 

Online price only excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Product details
  • Study structural and rheological properties simultaneously
  • Measure parallel or perpendicular to flow direction
  • Enhance existing SAXSpoint setups with RheoSAXS integration

More info

See more