Automated Multipurpose Powder X-Ray Diffractometer:
XRDynamic 500
- Out-of-box: Best-in-class resolution/signal-to-noise ratio
- TruBeam™ concept: Larger goniometer radius, evacuated beam path
- Full automation: X-ray optics and beam geometry change
- Efficiency: Increase instrument usage by up to 50 %
- Self-alignment: Instrument and sample for maximum convenience
XRDynamic 500 drives unbeatable XRD data quality with maximum efficiency. Enjoy the benefits of a versatile platform covering a wide variety of applications with optimal solutions for powder XRD, non-ambient XRD, PDF analysis, SAXS, and more. Intuitive to use, with fully automated optics and alignment routines, it allows everyone, from novices to experts, to collect top-quality XRD data quickly while minimizing errors. XRDynamic 500: Driving XRD.
Benefits
XRDynamic 500’s TruBeam™ concept combines a large goniometer radius, an evacuated beam path, and fully automated X-ray optics/beam geometry change. Measure an array of samples with varied instrument configurations assisted by intuitive software with optimized workflows. Achieve best-in-class resolution (FWHM <0.021° for 1st LaB₆ standard peak) with a standard Bragg-Brentano configuration. Enjoy a great signal-to-noise ratio with up to 50 % less measurement background and minimal parasitic air scattering. Quickly reconfigure for optimized non-ambient XRD experiments or SAXS measurements with the quality of a dedicated SAXS instrument.
- Switch between up to 3 beam geometries with a click
- Run different measurements sequentially with no user intervention
- Save time: Increase instrument usage by up to 50 %
Challenge
In many diffractometers, each measurement geometry requires parts to be exchanged by the user. Performing two completely different types of measurements sequentially is only possible after opening the instrument to manually change configurations.
Solution
Switch between up to 3 beam geometries with the click of a button (available for any type of X-ray tube used), thanks to a motorized optics stack. A unique source tilt axis allows every geometry to be precisely and automatically aligned.
Benefit
Automatic switching between up to 3 beam geometries makes it possible to run completely different types of measurements sequentially on different (or the same) samples with no exchange of parts or any user input required. Enjoy up to 50 % increased instrument uptime by running complex measurement batches overnight and on weekends without any user intervention.
- Automation of all optics
- More efficiency, fewer errors
- High-quality data for every user
Challenge
Selecting the correct optics often means swapping out components and updating the measurement configuration by hand in the measurement software. This is time-consuming, can lead to errors, and requires supervision or extensive training for more inexperienced users to routinely collect high-quality XRD data.
Solution
Full automation of all optical components in the beam path enables change of the instrument configuration with a click. No physical exchange of parts or user intervention is required.
Benefit
Save time and reduce the chance of user errors by automatically switching to the correct optics and always recognizing the current configuration. Measurement set-up is intuitive and straightforward even for users new to XRD.
- Instrument self-alignment without the need for a service visit
- Perfect automatic alignment for every measurement configuration
- Automatic alignment of each sample
Challenge
Alignment of a diffractometer, especially X-ray optics, requires expert knowledge or even a service visit. Sample alignment can also be difficult for inexperienced users.
Solution
Fully automated instrument alignment routines allow instrument self-alignment to be performed at any time. Automated sample alignment routines can be used for every sample.
Benefit
Cancel the service visit and let the instrument align itself. Ensure that the instrument (and sample) is always perfectly aligned for the best-quality data, to enjoy maximum uptime and reduced ownership costs.
- Intuitive, optimized measurement workflows
- Easy to use for beginners and experts
- Less user training time
Challenge
Conventional diffraction systems often appear to be complex arrays of multiple components which can be daunting to novice users. Experienced users may need to spend a lot of time setting up measurement plans and instrument configurations diverting focus from more important tasks.
Solution
XRDynamic 500 and the XRDdrive control software seamlessly combine straightforward instrument handling and intuitive workflows with as much detail as you want, and as little as you need, thanks to intelligent automation.
Benefit
Enjoy streamlined workflows that maximize the benefits of the XRDynamic 500 automation. Software that guides users through measurements allows experts and novices alike to work how they want while always trusting in best-in-class data quality.
- Novel beam concept delivering the perfect beam every time
- Best-in-class data quality
- Maximum measurement efficiency
Challenge
How can you ensure that you always work with the optimal beam and instrument configuration without making any sacrifices on data quality or measurement time?
Solution
The unique TruBeam™ concept brings together the Primux 3000 X-ray source, a large goniometer radius and evacuated optics, automated switching of the beam geometry and optics configuration, and automatic instrument and sample alignment into one complete package.
Benefit
Every user always achieves outstanding measurement performance for every sample and benefits from higher resolution, more options, and increased efficiency.
- >20 % better measurement resolution
- Superior resolution out-of-the-box – no expensive optics required
- Large goniometer radius as standard
Challenge
Many diffractometers offer a 240 - 300 mm measurement radius, which can limit the maximum achievable resolution without the use of expensive optics. You have to compromise with an accompanying loss of intensity.
Solution
XRDynamic 500 offers a larger goniometer radius of 360 mm or 400 mm as standard featuring evacuated optics and small detector pixel size.
Benefit
Compared with conventional diffractometers, XRDynamic 500 provides 20 % better measurement resolution for standard Bragg-Brentano measurements without compromising on the measured intensity, thanks to an evacuated beam path.
- Unbeatable signal-to-noise ratio
- Reduce measurement background by 50 %
- Eliminate the effects of air scattering
Challenge
To achieve a good signal-to-noise ratio and, therefore, excellent data quality, measurements must typically be performed with long counting times.
Solution
Benefit from evacuated optics to stop parasitic air scattering with the option for a fully evacuated beam path from source to detector.
Benefit
Reduce the measurement background by 50 % and benefit from unbeatable signal-to-noise ratio for the best quality data and shorter measurement times.
- High sample throughput and excellent data quality
- High-intensity measurement modes
- Faster workflows via intelligent automation
Challenge
With many instruments, data quality comes at the expense of measurement speed.
Solution
XRDynamic 500 offers outstanding data quality and primary beam intensity at all times no matter the measurement configuration, thanks to TruBeam™. Furthermore, automation of various workflows such as change of instrument configuration and alignment routines is included.
Benefit
Reduce measurement times without sacrificing data quality to increase sample throughput. Intelligent automation means less time sitting in front of the instrument and more time to focus on what matters.
- Powerful Primux 3000 source ideal for XRD and SAXS
- Exchange the X-ray tube in minutes
- Maximum primary beam intensity under all conditions
Challenge
Always working with the optimal X-ray tube anode is not easy, as exchanging the X-ray tube is often complex. Also, sacrifices in the primary beam intensity have to be made when working with different X-ray optics due to sub-optimal alignment of source to optic.
Solution
The intelligent design of the Primux 3000 X-ray source allows rapid exchange of the X-ray tube when required. Automatic alignment of every source and optic combination is possible.
Benefit
Take care of issues such as sample fluorescence at source. Exchange the X-ray tube, automatically align, and measure again with a new wavelength in <15 min. Always enjoy the maximum primary beam intensity thanks to precise alignment of every measurement geometry.
- High-intensity multilayer optics
- Parallel and focusing beam geometries
- Monochromators to maximize signal-to-noise ratio
Challenge
For certain samples or applications, beam shaping optics (parallel or focusing beam) are needed. In addition, monochromators may be required to suppress Kβ peaks and reduce measurement background.
Solution
A variety of multilayer monochromators, parallel beam and focusing optics can be mounted in a motorized optics stack and selected with a single click. A precise, automated alignment of every optic is realized with an optimized take-off angle. Special Ni/C multilayer optics offer intrinsic Kβ filtering for Cu and Co sources.
Benefit
Benefit from the highest possible intensity with all optics to reduce measurement time. A superior signal-to-noise ratio and outstanding resolution ensure the highest quality data.
- The latest pixel detector technology in 0D or 1D modes
- Small pixel size for high resolution
- Energy filtering
Challenge
High-quality XRD data requires a detector that can deliver an excellent resolution and signal-to-noise ratio.
Solution
Pixos detection units based on cutting-edge photon counting technology from Advacam enable measurement in 0D or 1D modes. XRDynamic 500 features a choice of Si or CdTe sensors to cover every wavelength, active energy filtering, and the smallest pixel size on the market (55 µm x 55 µm).
Benefit
In combination with the enlarged goniometer radius of XRDynamic 500, the small pixel size of the detectors improves the maximum measurement resolution with every wavelength. Pixos detection units also offer excellent energy resolution (with intelligent energy filtering), linearity, and efficiency.
- Flexibility in all applications
- Sample changers for high-throughput
- Excellent positional stability
Challenge
Handling different application requirements depends on having suitable sample stages available.
Solution
Versatile sample stages enable measurement in reflection and/or transmission of powders or solid samples with sample changer options available.
Benefit
Different sample types can be measured using the wide variety of sample stages. Component recognition allows every stage to work in a plug & play mode for quick mastery of all applications.
- Wide variety of sample holders
- Solutions for all sample types
- Optimized holders for weakly scattering and sensitive materials
Challenge
A true multipurpose diffractometer needs to handle all types of sample requirements.
Solution
A range of sample holders means there is a sample holder available for every type – powders, solids, films, fibers, gels, pastes, or liquids.
Benefit
Benefit from always working with a sample holder optimized to the sample at hand in reflection or transmission. Whether organic or inorganic, or even for air- or moisture-sensitive samples, XRDynamic 500 offers a solution.
- Non-ambient XRD made easy
- Plug & play stage functionality
- Built-in temperature control unit (CCU) for all stages
Challenge
Setting up a non-ambient XRD experiment can be complex and time-consuming. Typically, many cables and hoses need to be fed into the instrument housing to connect with external control units.
Solution
Enjoy the plug and play non-ambient stage functionality featuring a single built-in CCU control unit that works with all Anton Paar non-ambient stages. Benefit from convenient connections in the instrument housing for all non-ambient requirements.
Benefit
XRDynamic 500 makes non-ambient experiments as easy as performing any other measurement, so you can instantly reconfigure to a non-ambient configuration. A built-in CCU reduces clutter and avoids the need for multiple control units for different non-ambient attachments.
- SAXS data with the quality of a stand-alone-instrument
- Completely evacuated beam path from source to detector
- qmin down to 0.05 nm⁻¹
Challenge
Small-angle X ray scattering (SAXS) measurements on a diffractometer can typically only deliver data with a limited quality. For real high-quality SAXS measurements, a dedicated instrument is needed.
Solution
The combination of XRDynamic 500 with the EVAC module offers a fully evacuated beam path and dedicated SAXS optics to deliver a qmin of 0.05 nm⁻¹.
Benefit
Benefit from true SAXS measurements on a diffractometer. Only one instrument is needed to deliver the highest quality XRD and SAXS data.
Technical specifications
X-ray source | |
Source type | Primux 3000 |
X-ray generator | Up to 3 kW |
Tube voltage / current | 20 kV to 60 kV / 2 mA to 50 mA |
Goniometer | |
Configuration | Vertical Theta/Theta geometry |
Measurement radius | 360 or 400 mm |
Maximum usable angular range | -95° – 162.5° 2theta |
Minimum step size | 0.0001° |
2theta linearity | ≤0.01° |
Maximum angular speed | 15 °/sec |
Maximum angular resolution | 0.021° (FWHM of 1st LaB₆ peak) |
Sample stages and attachments | |
Ambient sample stages | Fixed sample stage Sample spinner stage (reflection/transmission) XY stage (with autosampler option) Capillary spinner stage EVAC module |
Non-ambient attachments | HTK 1200N HTK 16N/2000N HTK 1500 TTK 600 XRK 900 CHC plus⁺ BTS 150/500 |
Detectors | Solid-state hybrid pixel detectors:
|
Software |
|
General specifications | |
Exterior dimensions (width x depth x height) | 1350 mm x 1160 mm x 1850 mm |
Weight (not including optional accessories) | 750 kg |
Power supply | 3-Phase: 3/N/PE AC 400/230 V, 50…60 Hz, 25 A 1-Phase: 208…240 VAC, 50…60 Hz, 36 A |
Maximum power consumption (without additional controllers for optional equipment) | 5.5 kW |
Cooling water supply | Flow rate: > 3.6 L/min, Pressure: 4.5 – 6 bar, Temperature: < 25 °C |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Determining the Percentage Crystallinity of Polymers using X-ray Diffraction Application Reports
-
E-Book - Field Guide to Battery Materials Characterization – Revised and Updated Application Reports
-
E-Book - Field Guide to Food Powder Characterization Application Reports
-
E-Book - Field Guide to Food and Feed Testing Application Reports
-
E-Book - Field Guide to Pharmaceutical Powder Characterization Application Reports
-
High-Quality Pair Distribution Function (PDF) Analysis in the Home Laboratory Application Reports
-
Identifying Sugars in Food Products using X-ray Diffraction Application Reports
-
In-situ X-ray Diffraction on a LiCoO₂ Pouch Cell Battery Application Reports
-
Influence of the Experimental Setup on X-ray Diffraction Data of Zeolite ZSM-5 Application Reports
-
Operando X-ray Diffraction on a LiCoO₂ Coin Cell Battery Application Reports
Similar products
Consumables, Accessories & Software
Consumables, Accessories & Software
Accessories & Software
Accessories & Software
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
SPARE PARTS PASTECELL (300 °C)
HEATING STRIP PLATINUM 102x10x1 mm
HEATING STRIP PLATINUM 102x10x0.5 mm
REFLECTION SAMPLE HOLDERS FOR XY-6 STAGE (1 SD, 3 pcs)
REFLECTION SAMPLE HOLDERS FOR XY-12 STAGE (2.5 SD, 6 pcs)
REFLECTION SAMPLE HOLDERS FOR XY-12 STAGE (1 SD, 6 pcs)
SAMPLE CARRIER FLAT MADE OF PLATINUM FOR HTK OVEN CHAMBER
SAMPLE CARRIER 0.8mm DEEP MADE OF PLATINUM FOR HTK OVEN CHAMBER
High-Temperature Chamber:
HTK 1500
- ‘True’ environmental heater from 25 °C to 1,500°C
- Highest temperature accuracy for your experiments
- Swiftly convert from reflection to transmission measurements
- Conduct measurements in different gas atmospheres
- Perfectly complements the XRDynamic 500 multi-purpose diffractometer
SPARE PARTS XRDynamic 500
- set of O-rings
- set of window foils for primary and secondary optics units
- Vacuum grease
Sealed-Tube X-ray Source:
Primux 3000
- Powerful X-ray source for advanced X-ray analysis
- Available with a wide variety of anode materials
- Simple exchange of X-ray tube or change of tube focus
Advanced XRD Optics
- High-intensity multilayer X-ray optics
- Parallel and focusing beam optics suitable for every wavelength
- Maximum Kβ suppression with primary monochromators
XRD Detection Units:
Pixos
- Implements the latest CERN pixel detector technology with advanced noise reduction
- Measure in 0D or 1D modes with a choice of sensor material
- Smallest pixel size (55 µm x 55 µm) for outstanding resolution
- Energy filter to further minimize measurement background
Sample Stages and Sample Holders for XRDynamic 500
- Versatile sample stages for all applications
- Sample changer options for high-throughput measurements
- Stages for operando battery measurements
- A wide variety of sample holders for different sample types
Evacuated Chamber for High-Resolution SAXS and XRD:
EVAC Module
- Unbeatable signal-to-noise ratio due to fully evacuated beam path
- Dedicated SAXS optics for measurements with the quality of a stand-alone SAXS instrument
- Suitable for high resolution XRD studies in reflection or transmission
- Measure without any restriction of the 2θ range
Low-Temperature Chamber:
TTK 600
- Non-ambient attachment for X-ray diffraction studies from -190 °C to 600 °C
- For investigations on samples in reflection and transmission geometry
- Also for air-sensitive samples and in-operando studies on batteries
- Fits to all common powder diffractometers
High-Temperature Strip Heater Chambers:
HTK 16N | HTK 2000N
- Supports in-situ XRD studies at up to 1,600 °C or 2,300 °C
- Minimized sample displacement with stable heating filament positioning
- Precise temperature control with dual thermocouples and minimal gradients
- Durable design with high-grade materials and quick, easy sample exchange
Cryo & Humidity Chamber:
CHC plus⁺
- Condensation-free experiments under rel. humidity and temperature
- Overall temperature range from -180 °C to +400 °C;
Controlled relative humidity studies from 10 °C to 80 °C - Easy changeover from low-/high-temperature experiments to humidity measurements without opening the chamber
Reactor Chamber:
XRK 900
- Reactor chamber for all common diffractometers
- For solid state and solid state-gas reactions up to 900 °C and 10 bar
- Sample holder options: chemically resistant materials, sample spinning, open holders for gas extraction through the sample
Benchtop Heating Stages:
BTS 150 | BTS 500
- Compact, patented design optimized for benchtop XRD applications
- Temperature control range: -10 °C to +150 °C (BTS 150) and up to 500 °C (BTS 500)
- Fast, accurate temperature control with sensor near the sample
- Straightforward sample handling, alignment, and remote control via USB
High-Temperature Oven Chamber:
HTK 1200N
- Supports in-situ XRD studies up to 1,200 °C in various atmospheres
- Precise and reliable temperature measurement with excellent uniformity
- Sample spinning option for improved data quality and flexible sample carriers
- Durable, compact design compatible with most goniometers
XRD Software:
XRDanalysis
- Versatile software package for powder diffraction analysis
- Search/match feature for rapid and accurate phase identification
- Rietveld analysis using matched or manually loaded phases
- Optimized analysis workflows including batch analysis to speed up and simplify your analytical tasks