Benchtop Heating Stages:
BTS 150 | BTS 500
- Compact, patented design optimized for benchtop XRD applications
- Temperature control range: -10 °C to +150 °C (BTS 150) and up to 500 °C (BTS 500)
- Fast, accurate temperature control with sensor near the sample
- Straightforward sample handling, alignment, and remote control via USB
The BTS 150 and BTS 500 Benchtop Heating Stages are the first commercial non-ambient stages for XRD studies on benchtop diffractometers. Their unique design is patented and offers all the features a benchtop diffraction application requires - compactness, reliability and ease of use!
Measurements can be performed between –10 °C and 150 °C with the BTS 150 and from ambient to 500 °C with the BTS 500. Both instruments are extremely compact in design to fit into the restricted space of typical benchtop diffractometers.
Key features
Fast and accurate temperature control
- Temperature range from –10 °C to 150 °C (BTS 150)
or from ambient to 500 °C (BTS 500) - Accurate temperature measurement by a thermo sensor close to the sample
- Fast heating and cooling
Optimized for ease of operation
- Easy handling and exchange of samples
- Easy alignment possibilities
- High position stability and minimum thermal expansion of sample holder
- Adjustable beam knife to minimize background at low 2θ
- Remote control via USB connection possible
Optimized design for benchtop instruments
- Compact and lightweighted design with integrated temperature controller
- No external cooling required (only air cooling) for BTS 500 or optional water cooling for BTS 150 at lowest temperatures
Technical specifications
Operating temperature | ambient to 500 °C (BTS 500) -10 to 150 °C (BTS 150) |
---|---|
Temperature measurement | Pt100 |
Atmosphere | Vacuum (10-1 mbar), air, inert gas, nitrogen |
Angle of incidence (2Θ) | 0 to 164° |
Max. operating pressure | 1 bar above atmospheric pressure |
Sample holder material | Nickel or ceramics (Al2O3) |
Sample size | 16 x 14 mm |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
BTS 150/500 Benchtop Heating Stages Brochures
Compatible instruments
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
ALIGNMENT BLOCK BTS
ZERO BACKGROUND INSERT Si (510) FOR BTS
SET OF KAPTON FOILS (5 pcs.)
SET OF O-RINGS BTS
NON-AMBIENT GUIDE
STANDARD SAMPLE HOLDER BTS (0.8 mm DEPTH)
STANDARD SAMPLE HOLDER BTS (0.2 mm DEPTH)
STANDARD SAMPLE HOLDER BTS (FLAT)
SAMPLE HOLDER BTS CERAMICS (0.8 mm DEPTH)