Benchtop Heating Stages:
BTS 150 | BTS 500

  • Benchtop Heating Stage BTS 500
  • Benchtop Heating Stage BTS 500
  • Benchtop Heating Stage BTS 500
  • Benchtop Heating Stage BTS 500
  • Benchtop Heating Stage BTS 500
  • Benchtop Heating Stage BTS 500

The BTS 150 and BTS 500 Benchtop Heating Stages are the first commercial non-ambient stages for XRD studies on benchtop diffractometers. Their unique design is patented and offers all the features a benchtop diffraction application requires - compactness, reliability and ease of use!

Measurements can be performed between –10 °C and 150 °C with the BTS 150 and from ambient to 500 °C with the BTS 500. Both instruments are extremely compact in design to fit into the restricted space of typical benchtop diffractometers.
 

Key features

Fast and accurate temperature control

  • Temperature range from –10 °C to 150 °C (BTS 150)
    or from ambient to 500 °C (BTS 500)
  • Accurate temperature measurement by a thermo sensor close to the sample
  • Fast heating and cooling

Optimized for ease of operation

  • Easy handling and exchange of samples
  • Easy alignment possibilities
  • High position stability and minimum thermal expansion of sample holder
  • Adjustable beam knife to minimize background at low 2θ
  • Remote control via USB connection possible

Optimized design for benchtop instruments

  • Compact and lightweighted design with integrated temperature controller
  • No external cooling required (only air cooling) for BTS 500 or optional water cooling for BTS 150 at lowest temperatures

Technical specifications

Operating temperature

ambient to 500 °C (BTS 500)
-10 to 150 °C (BTS 150) 

Temperature measurement Pt100
Atmosphere Vacuum (10-1 mbar), air, inert gas, nitrogen
Angle of incidence (2Θ) 0 to 164°
Max. operating pressure 1 bar above atmospheric pressure
Sample holder material Nickel or ceramics (Al2O3)
Sample size 16 x 14 mm

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Compatible instruments

Consumables

Consumables

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

Online price only | excl.incl. 0VAT

STANDARD SAMPLE HOLDER BTS (0.8 mm DEPTH)

Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 163148
Product details
Spare sample holder with a cavity of 0.8 mm depth.

STANDARD SAMPLE HOLDER BTS (0.2 mm DEPTH)

Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 164360
Product details
Spare sample holder with a cavity of 0.2 mm depth.

STANDARD SAMPLE HOLDER BTS (FLAT)

Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 164361
Product details
Spare sample holder without cavity.

SAMPLE HOLDER BTS CERAMICS (0.8 mm DEPTH)

Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 165915
Product details
Spare sample holder with a cavity of 0.8 mm depth made of ceramic material.