此為必填欄位。
Invalid
零件編號
驗證錯誤!

科里奧利質量流量計:
L-Cor 8000

  • The image shows an Anton Paar L-Cor 8000 Coriolis flow meter, a high-precision inline instrument used for measuring fluid properties directly in industrial processes.
  • Coriolis flow meter L-Cor 8000 held by a technician in protective gear, standing in an industrial piping system with valves and gauges.
  • Installed Anton Paar L-Cor 8000 Coriolis flow meter with digital display mounted on stainless steel piping system with valves and sensor connections.
  • Anton Paar L-Cor 8000 Coriolis flow meter with display mounted on frost-covered stainless steel piping in a cold industrial processing environment.
  • Anton Paar L-Cor 8000 Coriolis flow meter installed in stainless steel piping system, technician in safety gear recording data on a tablet.
  • Technician in safety gear using a wrench to adjust an installed Anton Paar L-Cor 8000 Coriolis flow meter on stainless steel piping system.
  • The image shows an Anton Paar L-Cor 8000 Coriolis flow meter, a high-precision inline instrument used for measuring fluid properties directly in industrial processes.
  • Coriolis flow meter L-Cor 8000 held by a technician in protective gear, standing in an industrial piping system with valves and gauges.
  • Installed Anton Paar L-Cor 8000 Coriolis flow meter with digital display mounted on stainless steel piping system with valves and sensor connections.
  • +3
  • 客製化高精度流量量測解決方案
  • 高精度量測,流量範圍涵蓋 0.4 g/min 至 1,400 t/h
  • 操作溫度範圍廣:-200 °C 至 +350 °C
  • 單一儀表即可量測質量流量、密度與濃度
  • 從感測器配置到全生命週期的專業支援
     

L-Cor 8000 系列科里奧利質量流量計可為質量流量、密度與濃度量測提供完整解決方案。
即使在嚴苛的產業與製程條件下(例如極端溫度、高壓或高黏度介質),此系列感測器仍可提供精確的流量、密度與濃度量測。 
憑藉專業建議與完善的客戶服務,我們協助您找到符合製程需求的解決方案,並在整個產品生命週期內持續提供支援。

主要功能

從微克到百萬噸:單一流量計,適用各種產業與規模

從每分鐘 0.4 克的香精等微量投加應用,到高達每小時 1,400 公噸的大流量交接計量,L-Cor 8000 系列皆可在全量程內精準量測流量、密度與濃度。 

Coriolis flow meter L-Cor 8000 held by a technician in protective gear, standing in an industrial piping system with valves and gauges.

專為極端工況設計的科里奧利質量流量計

即使在最嚴苛的環境中,科里奧利質量流量計感測器仍具備耐用性與長使用壽命,可涵蓋高達 400 °C 的溫度範圍、承受超過 400 bar 的製程壓力,並通過危險區域認證。 深冷型可量測低至 -200 °C 的介質溫度,高溫型則可在最高 +350 °C 的條件下進行流量監測。 即使是黏度超過 10,000 mPa·s 的介質,也能穩定量測。 提供多種接液材質選項,包括不鏽鋼與 Alloy C,以滿足不同製程介質的相容性需求。

Installed Anton Paar L-Cor 8000 Coriolis flow meter with digital display mounted on stainless steel piping system with valves and sensor connections.

可靠的氣體流量監測

L-Cor 8000 科里奧利質量流量計非常適合精準量測乾燥氣體流量,在不同氣體種類、溫度或製程壓力條件下,仍能維持高準確度。
其堅固且免維護的設計,即使在嚴苛的製程條件下,也能維持穩定可靠的量測性能。 高量測精度有助於實現更嚴謹的製程控制,因此特別適用於飲料與化工製程,以及能源與燃氣輸配應用。

Anton Paar L-Cor 8000 Coriolis flow meter with display mounted on frost-covered stainless steel piping in a cold industrial processing environment.

已取得交接計量認證

Anton Paar 的科里奧利質量流量計適用於交接計量應用,可提供可追溯的量測結果。 全面符合 OIML R 117-1、MC 等規範,並依據 ISO/IEC 17025 取得認證,可滿足各產業商業結算計量對準確度與完整性的要求。

Anton Paar L-Cor 8000 Coriolis flow meter installed in stainless steel piping system, technician in safety gear recording data on a tablet.

值得信賴的專業支援

Anton Paar 憑藉豐富的應用專業知識、世界級的客戶支援與完善的售後服務,深受客戶信賴;所有流量計均提供三年標準保固。
自合作開始,您即可獲得專業團隊支援;團隊在流量、密度與濃度監測領域具備豐富知識與經驗,服務涵蓋多元產業與應用。憑藉遍佈全球的服務網絡與逾一百年的量測經驗,我們能為您提供符合需求的客製化解決方案。

Technician in safety gear using a wrench to adjust an installed Anton Paar L-Cor 8000 Coriolis flow meter on stainless steel piping system.

規格

 L-Cor 8000L-Cor 8100L-Cor 8200L-Cor 8300
流量0.024 kg/h 至 9 kg/h0.72 kg/h 至 72 kg/h3.6 kg/h 至 120,000 kg/h3420 kg/h 至 700,000 kg/h108 kg/h 至 342,000 kg/h108 kg/h 至 700,000 kg/h24 kg/h 至 2,550 kg/h
液體流量精度± 0.2%± 0.1%± 0.1% ± ZS± 0.1%*± 0.2% ± ZS
液體流量重複性± 0.05%± 0.05% ± ZS± 0.05%± 0.1% ± ½ ZS
氣體流量準確度± 0.5% ± ZS-± 0.5% ± ZS± 0.5% ± ZS
氣體流量重複性± 0.25% ± ½ ZS-± 0.25% ± ½ ZS± 0.25% ± ½ ZS
密度範圍300 kg/m3 至 2,000 kg/m3
密度準確度± 3 kg/m3± 0.5 kg/m3± 3 kg/m3± 0.5 kg/m3± 4 kg/m3
公稱直徑1/4"3/8"3/8" 至 3"4" 至 6"1" 至 6"1/2"
環境溫度- 40 °C 至 +55 °C
製程溫度- 200 °C 至 +200 °C-40 °C 至 +350 °C-200 °C 至 +50 °C-200 °C 至 +200 °C
絕對製程壓力150 bar(20 °C 時)依凸緣規格而定最高 430 bar(20°C 時)
製程連接螺紋 R 1/4ASME B16.5 Class 150, 300, 600
EN 1092-1 PN40
Tri-clamp ISO 2852
螺紋 R/Rc
ASME B16.5 Class 150, 300, 600
EN 1092-1 PN16, 40
Rc 3/8
Rc 3/4
接液部件1.4404 (316L)1.4404 (316L)
Alloy C-22
1.4404 (316L)
潛在爆炸性環境認證ATEX、IECEx、CSA (C-US)、NEPSI (CCC)
輸出2x 類比,2x 脈衝(頻率),1x 狀態輸出
輸入1x 狀態輸入
數位通訊Bell 202、Modbus RTU (RS-485)、Profibus PA、Fieldbus
變送器版本整合式、分離安裝式、安裝於控制櫃內
認證OIML R117-1:2019(根據 WELMEC 8.8 與 7.2)

* 當流量低於最大量程的 5 % 時,適用 ± ZS。 準確度規格於參考條件下有效。 ZS = 零點穩定性誤差 = (零點穩定性)/(瞬時流量) ×100%