此為必填欄位。
Invalid
零件編號
驗證錯誤!

超高壓科里奧利流量計:
L-Cor 8500

  • L-Cor 8500 super-high-pressure Coriolis flow meter mounted on stainless steel pipe section with flange plate and process connection
  • Aerial view of an industrial tank farm with multiple horizontal storage vessels arranged in parallel, connected by piping, valves, and elevated pipe racks
  • Technician wearing hard hat and safety glasses holding L-Cor 8500 Coriolis flow meter in front of industrial piping and process equipment
  • Technician using a wrench to install L-Cor 8500 Coriolis flow meter on industrial pipeline with multiple L-Cor 8500 transmitters and gauges
  • L-Cor 8500 super-high-pressure Coriolis flow meter mounted on stainless steel pipe section with flange plate and process connection
  • Aerial view of an industrial tank farm with multiple horizontal storage vessels arranged in parallel, connected by piping, valves, and elevated pipe racks
  • Technician wearing hard hat and safety glasses holding L-Cor 8500 Coriolis flow meter in front of industrial piping and process equipment
  • +1
  • 適用於壓力高達 120 MPa (17,405 psi) 的超高壓應用
  • 高精度:適用於 2.4 kg/h 至 300 kg/h 的流量範圍
  • 一體式流量計,可量測質量流量、密度與濃度
  • 取得 ATEX 認證:適用於危險區域
  • 從感測器配置開始,整個生命週期皆可獲得專業指導

L-Cor 8500 超高壓科里奧利流量計可為超高壓流體的流量、密度與濃度量測提供最佳一體式解決方案。 憑藉專業諮詢與專屬支援,Anton Paar 協助您找到最符合製程需求的方案,並在整個產品生命週期中持續提供支援。

主要功能

專為極端條件而設計

Anton Paar 超高壓科里奧利流量計專為嚴苛工況設計,製程壓力最高可達 1,200 bar(17,405 psi)。 感測器採用抗脆化合金製成,尤其適用於超高壓應用,例如氫氣加注,以及石油與天然氣產業中的化學注藥。
我們的專家會先深入了解您的製程需求,協助您選擇符合使用工況的解決方案。

L-Cor 8500 super-high-pressure Coriolis flow meter mounted on stainless steel pipe section with flange plate and process connection

可靠的液化氣體流量監測

L-Cor 8500 超高壓科里奧利流量計可精確量測 H2 或 N2 等液化氣體的流量。 它可直接量測實際質量流量,不受氣體可壓縮性影響,且不論氣體種類、溫度或製程壓力如何,皆可維持高準確度。 此感測器即使在嚴苛條件下,仍可提供穩定且高準確度的量測結果,有助於在超高壓應用中實現精密的製程控制。

Aerial view of an industrial tank farm with multiple horizontal storage vessels arranged in parallel, connected by piping, valves, and elevated pipe racks

在最嚴苛條件下依然安全

我們的高壓科里奧利流量計專為耐用性與長使用壽命而設計,即使在具化學侵蝕性的環境中,也能穩定運作。 提供多種接液材質選項,包括不鏽鋼與 Alloy C,可確保與您的製程介質達到最佳相容性,特別適用於對耐腐蝕性與化學穩定性至關重要的嚴苛應用。

Technician wearing hard hat and safety glasses holding L-Cor 8500 Coriolis flow meter in front of industrial piping and process equipment

值得信賴的專家支援

Anton Paar 以深厚的應用專業知識、世界級的客戶支援與全面的售後服務著稱,所有流量計皆享有標準三年保固。
從導入第一天起,您即可獲得專業團隊的支援;團隊在各類產業與應用的流量、密度及濃度監測領域,具備豐富知識與經驗。 憑藉全球服務網路與超過 100 年的量測經驗,我們可依據您的特定需求提供客製化解決方案。

Technician using a wrench to install L-Cor 8500 Coriolis flow meter on industrial pipeline with multiple L-Cor 8500 transmitters and gauges

規格

 L-Cor 8500 UHPL-Cor 8500 SHP
公稱尺寸9/16”3/8”
接液部件TPXM-19 UNS S20910 SA-312 (1.3964)Alloy-C22 (2.4602)
變送器外殼ADC12 (AlSi11Cu3)
感測器外殼304/1.4301
製程連接高壓錐面與螺紋連接, 
尺寸 9/16 562C(外螺紋 1*1/8-12 UNF)
高壓錐面與螺紋連接, 
尺寸 3/8 375C(外螺紋 3/4-16 UNF)
製程介質液體和氣體
操作密度範圍0 至 2 g/cm3 (0 至 124.86 lb/ft³) (無密度測量)
測量範圍9.6 至 300 kg/h (21.2 至 661 lb/h)9.6 至 240 kg/h (21.2 至 529 lb/h)
準確度± 讀值的 0.5%
重複性讀值的 ± 0.25%
製程溫度-40°C 至 130°C (-40°F 至 266°F)
環境溫度-40°C 至 55°C (-40°F 至 131°F)
最大製程壓力1200 bar (17,405 psi)950 bar (13779 psi)
流向雙向
可在危險區域使用ATEX/IECEx, CSA(CUS)
重量約 21 kg (46 lb)
輸出2x 類比,2x 脈衝(頻率),1x 狀態輸出
輸入1x 狀態輸入
數位通訊HART、Modbus RTU (RS-485)、Profibus PA、Fieldbus
變送器版本整合式、分離安裝式、安裝於控制櫃中

安東帕認證服務

安東帕在服務和支援方面的品質:
  • 全球超過 350 位製造商認證的技術專家
  • 以當地語言提供的合格支援
  • 在整個儀器生命週期中保護您的投資
  • 三年保固
深入瞭解

相似產品