Abel Flash Point Tester:
ABA
- Flash point with a range from 10 °C to 110 °C
- Full compliance with ISO 13736, ISO 1516, ISO 1523, and more
- Patented electric igniter with ceramic coating, for 10x longer lifetime than that of competitor solutions
- Budget-friendly instrument with comprehensive feature set
Anton Paar’s Abel closed-cup flash point tester series – ABA 500 and ABA 300 – offers next-generation flash point testing. Easily determine the flash point according to ISO 13736, ISO 1516, ISO 1523, and more. Perform automatic, high-precision flash point testing of samples like jet fuels, solvents, flavors and fragrances, and chemicals. Innovative cooling options permit flash point testing across a temperature range from -35 °C to +130 °C. Both Abel flash point testers offer excellent heating control and a full feature set for accurate flash point results. The clever instrument design maximizes productivity and saves costs as the electric igniter has the longest lifetime on the market.
Key features
Award-winning, high-quality components with the longest lifetime on the market
The Abel flash point testers series is built with high-quality components for top precision, reliability, and unparalleled robustness, guaranteeing consistent flash point results over time.
- Electric igniter: A patented design and ceramic coatings deliver a 10x longer lifetime than that of competitor solutions, eliminating downtime due to igniter failures
- Multi-function head: Automatically connects with temperature and flash point detection sensors without the need for cables or plugs
- Easy calibration and adjustment of sensors and stirrer on-site to guarantee reliable results
- A whole portfolio of test equipment, including test cups made from brass or stainless steel, for more flexibility when measuring valuable or corrosive samples
The most powerful, intuitive Abel flash point tester on the market
- Simple and intuitive test setup so you can get started right away
- Smart user interface is operated via a 7” touchscreen - Customizable user interface based on your needs (e.g., display of all relevant data during a flash point test in real time, quick access to frequently used functions)
- Guided workflows take you through all necessary steps to obtain standard-compliant flash point testing results, supported by status light
- Disassembly of wetted parts within seconds
- Quick, hassle-free cleaning prevents false results from sample carry-over
Super-flexible, two-in-one cooling for the widest flash point range on the market
ABA 500 is equipped with a game-changing Peltier cooling system for Abel flash point testing.
- Unparalleled two-in-one instrument combination for top flexibility and the widest sample range on the market
- Connection of instrument to an external chiller to measure flash points at very low temperatures (sample temperature between -35 °C and +130 °C)
- Internal cooling system: flash points between 10 °C and 130 °C without external chiller
ABA 300 is equipped with a budget-friendly, fan-supported Peltier cooling system.
- Measurement of flash points between 10 °C and 110 °C
Maximum safety for operator and lab
ABA 500 is one of the safest Abel flash point testers available on the market.
- Equipped with a fire extinguisher combined with a fail-safe fire detection system as standard
- Monitoring of the instrument’s status with two independent detectors, a fire ionization detector, and an optical IR sensor
- In case of fire, the fire extinguisher is triggered, and the instrument terminates all measurements
ABA 300 can be equipped with the optional combination of a fire extinguisher and a unique fire detection system.
All your measurement data – fully automatic, wherever you need it
Whatever the scope of your business, there’s a connectivity solution for you.
- Automatic integration of your test results into your working environment
- Easily print reports or go completely paperless – from automated e-mail or LIMS export to any location in your network, to Anton Paar’s fully implemented lab execution software AP Connect
- Increasing productivity in your lab and improving data quality with AP Connect gives you time to focus on evaluation and analysis
- With AP Connect, store tens of thousands of measurements in a single digital space, available at a snap, and accessible from any network computer, anytime
Abel flash point testers are compliant with all relevant standards
- Full compliance with international and national Abel flash point methods: ISO 13736, IP 170, ISO 1516, ISO 1523, IP 491, IP 492, EN 924, and more
- Simple specification of user-defined methods for non-equilibrium and equilibrium Abel flash point testing with our intuitive guided user interface
- Guided calibration procedures for temperature, barometric pressure, and stirrer speed for top precision and the highest repeatability
Technical specifications
ABA 300 | ABA 500 | |
Test methods | EN ISO 13736, IP 170 Equilibrium procedures: EN ISO 1523, IP 492, EN 924 | EN ISO 1516, IP 491 >1,000 user-defined test programs | |
Application range (flash point temperature) | 10 °C to 110 °C | Air-cooled 10 °C to 130 °C Liquid-cooled -30 °C to +130 °C |
Sample temperature range | -7 °C to +110 °C | Air-cooled -7 °C to 130 °C Liquid-cooled -35 °C to +130 °C |
Ignition type | Electric (encapsulated hot wire) | Electric (encapsulated hot wire) Optional gas ignition |
Stirring speed | According to standard or user-defined | |
Heating rate | According to standard or user-defined | |
Cooling | Fan-supported Peltier cooling technology | Fan- and liquid-supported Peltier cooling technology |
Barometric pressure correction | Flash point is automatically corrected to barometric pressure | |
Flash detection | Automatic detection by thermocouple | |
Sample temperature | Automatic by Pt100 | |
Safety | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Optional automatic fire-extinguishing system in combination with a unique optical fire detection system User management with different access levels | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Automatic fire-extinguishing system in combination with a unique optical fire detection system as standard User management with different access levels |
Calibration | Calibration of sample and block temperature, stirrer speed, and internal barometer | |
Handling | TFT touchscreen | Small footprint | Manual lifting/lowering of multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time | TFT touchscreen | Small footprint | Fully automatic multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
Memory | 1 GB space for approx. 50,000 tests and 1,000 users | |
Statistics | Mean, min, max, repeatability, standard deviation, max. deviation | |
Interfaces | 2 × USB, 1 × LAN | 4 × USB, 1 × LAN |
Input options | Optional USB keyboard/mouse/barcode reader | |
Display | 7" TFT, PCAP touchscreen | |
Power supply | 100 V to 240 V, 50/60 Hz, 300 W | |
Gas supply | Optional fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa | Integrated fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa Optional gas ignition: 50 mbar of propane or butane |
Dimensions | 262 mm × 472 mm × 437 mm (W × D × H) | 262 mm × 497 mm × 477 mm (W × D × H) |
Weight | Ca. 14 kg | Ca. 15 kg |
Options | Standard test insert in brass or stainless steel, mini-cup insert in brass or stainless steel, calibration set, condensation protection, draft shield Fire extinguisher | Standard test insert in brass or stainless steel, mini-cup insert in brass or stainless steel, calibration set, condensation protection, draft shield Gas igniter |
Standards
EN
IP
ISO
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
ABA 300: Measuring Jet Fuel Samples Application Reports
-
ABA 500: Ethanol content in cosmetic products Application Reports
-
ABA 500: FAM ILS Testing Program for Flash Points of Jet Fuel Application Reports
-
ABA 500: Measuring Jet Fuel Samples Application Reports
-
ABA X00: Correlation between standard cup and mini-cup Application Reports
-
Testing the flammability of battery electrolytes with ABA X00 Application Reports
-
Brochure: Flash Point Testers Brochures
-
Datasheet: ABA X00 Brochures
-
Reference Guide: ABA X00 Manuals
-
CoC ABA 300 version 1.3.6 Software and Firmware
-
CoC ABA 500 version 1.3.6 Software and Firmware
-
Release notes - ABA 300 version 1.3.6 Software and Firmware
-
Release notes - ABA 500 version 1.3.6 Software and Firmware
-
Software update - ABA 300 version 1.3.6 Software and Firmware
-
Software update - ABA 500 version 1.3.6 Software and Firmware
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
MULTI-DETECTOR, STANDARD, ABA X00
ABA 300 | 500
PVC HOSE WITH FABRIC, d = 10 mm, 2 m
ABA 300 | 500
PVC HOSE WITH FABRIC, d = 10 mm, 3 m
ABA 300 | 500
PVC HOSE WITH FABRIC, d = 10 mm, 4 m
ABA 300 | 500
CONDENSATION PREVENTION KIT
ABA 300 | 500
- Condensation prevention shield (P/N 257661)
- Sealing for condensation prevention shield (P/N 257660)
- Bottom sealing of condensation prevention shield (P/N 257659)
ELECTRIC IGNITER SET ABA X00, TAG X00