SAXS/WAXS System:
SAXSpoint 700
- Unique measurement chamber – endless experimental possibilities
- Brilliant results, thanks to best-in-class beam delivery system
- Investigate porosity, orientation, size, shape, structure, crystallinity of nanostructures
- Accelerate research and ensure quality with automation
- Obtain meaningful results thanks to powerful analysis software
SAXSpoint 700 is the ultimate SAXS/WAXS/GISAXS/USAXS/RheoSAXS laboratory beamline with synchrotron detector technology for the highest resolution in a compact system. Anton Paar’s brilliant SAXS system resolves nanostructures up to 620 nm. SAXSpoint 700 offers flexible analysis of almost any material under ambient, non-ambient conditions - even air. With its spacious measurement chamber, this SAXS system provides endless experimental possibilities. Easily perform non-destructive investigations of material properties via powerful software packages that enable automatic operation and data analysis. A wide range of features equip SAXSpoint 700 for future applications, with USAXS also including the micrometer range.
Key features
A SAXS System with Endless Experimental Possibilities
SAXSpoint 700’s new and improved measurement chamber opens up endless possibilities with its size, a wealth of sample environments, and customization for specific experiments. Tailor your SAXS system to your requirements so that you can take on nanostructured material analysis with ease. Seamlessly switch between different sample stages thanks to the SAXSdrive™ software and automatic stage recognition, which ensures automatic alignment of all components. Cover an impressive temperature range of -150 °C to 500 °C, combine full rheological and nanostructural investigations with the RheoSAXS module, and conduct automated studies with temperature-controlled samplers - even in air.

Pure brilliance
Take on difficult samples with the help of the best-in-class beam delivery system. Thanks to a brilliant X-ray beam with the highest spectral purity (>99.9 % Cu Kα) and scatterless beam collimation, users are guaranteed synchrotron-like data quality (including SAXS/WAXS/GISAXS/USAXS/RheoSAXS) with minimum effort and the shortest exposure times.
This SAXS system, with its brilliant setup and industry-leading optical system, enables the resolution of structures up to 620 nm (USAXS up to the µm range), at the most compact system size (3.6 m x 0.9 m).

SAXS and WAXS in one go
Obtain SAXS and WAXS data in one go with Slidemaster. Without any additional realignment of the SAXS system necessary, save time by cutting out any setup steps between measurements. Simply choose your optimum q-range from the highest SAXS resolution to a wide WAXS regime for every experiment. What's more, due to the automatic beamstop selection, another step is taken out of the whole process, saving you time and effort. With EIGER2 R detectors even fully beamstop-less measurements are possible.

Powerful software and unique scripting capabilities
The intuitive SAXSdrive™ and SAXSanalysis™ software solutions are combinable with automated routine steps, allowing you to set up your experiment whilst you get on with more important tasks. Analyze your 1D and 2D data sets using customizable templates, and determine parameters like the radius of gyration (Rg), particle size, Porod constant, specific surface and Kratky plot. Export your data to all popular packages for further analysis.
Benefit from full control of your experiments with scripting capabilities provided by a unique Python API: the perfect setup for advanced usage of the SAXS system.

Support when you need it
Get the most back from your investment with Anton Paar's standard three-year warranty. Maximize your SAXS system’s uptime with immediate responses to service requests. Should you need application support, there is always an application expert nearby in over 35 subsidiaries around the globe.

Technical specifications
X-ray source | Primux 100 micro microfocus X-ray source (Cu, Mo; other target materials on request) Optional dual microfocus X-ray sources (Cu and Mo; other target materials on request) High-performance Ga/In MetalJet source |
X-ray optics and collimation | Custom-designed AXO ASTIX/ASTIX++ optics (fully evacuated) Automated scatterless beam collimation (fully evacuated) |
Sample stages and autosamplers | TCStage temperature-controlled stages (-150 °C to 500 °C) Customized solutions available on request |
Special features | Slidemaster: moving detector (translation in X,Y,Z) TrueFocus: automatic self-alignment TrueSWAXS: continuous and simultaneous SWAXS studies Stagemaster: XYZ stage with auto-recognition of sample stages Optional high-resolution WAXS module Optional high-performance ASTIX++ optics enabling a flux of > 6 x 108 ph/s |
Temperature range | -150 °C to +500 °C |
Temperature accuracy | ±0.1 °C |
Atmosphere | Vacuum, air, inert gas, humidity (reactive gases on request) |
Sample holders | Quartz capillary for liquids Customized solutions available on request please contact us |
Detectors | 2D EIGER2 R and PILATUS4 R series HPC detectors High-resolution WAXS module (EIGER2 R series) |
Accessible q-range | 0.01 nm-1 to 49.3 nm-1 (main detector) |
Software | SAXSdrive™ measurement and acquisition software SAXSanalysis™ data processing and analysis software |
Footprint | 3.6 m x 0.9 m (Microsource version, L x W) 4.5 m x 0.9 m (MetalJet version, L x W) |
Standards
ISO
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
An Insight into the Structure of Copolymer Surfactants Application Reports
-
An Insight into the Structure of Surfactants Application Reports
-
Coir Fibers - SWAXS Studies of Structural Changes Induced by Tensile Stress Application Reports
-
Combined Rheo-SAXS Investigations using a Laboratory SAXS System Application Reports
-
Continuous SWAXS Data Studies with the EIGER2 R 500K WAXS Module Application Reports
-
Determining the Number Concentration of Gold Nanoparticles by SAXS Application Reports
-
Evaluating GISAXS Data with SAXSanalysis Using the BornAgain Export Application Reports
-
Fast SAXS Studies of Sensitive Biological Samples Application Reports
-
In-line SEC-SAXS of HSA Protein Using a Laboratory SAXS Instrument Application Reports
-
In-situ GISAXS heating experiments on self-assembled Gold nanoparticles Application Reports
-
Laboratory Rheo-SAXS Studies of Non-ionic Surfactants Application Reports
-
Protein Mass Determination using Small Angle X-Ray Scattering Application Reports
-
Protein Shape Determination by Small Angle X-Ray Scattering Application Reports
-
SAXSpoint 700: SAXS Measurements of Nanomaterials under Ambient Conditions Application Reports
Similar products
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.

SPARE PARTS SAXSess HOUSING

PASTECELL WINDOWS FOR 120 °C (100 Pcs.)

SPARE PARTS PASTECELL (120 °C)

SPARE PARTS QUARTZ CUVETTE

PHỤ TÙNG FLOW CELL (SAXSess)

SPARE PARTS µ-CELL

WATERFILTER R50 FOR SEALED TUBE GENERATOR COOLING CIRCUIT

WARNING LAMP "X-RAY ON" FOR ID3003 GENERATOR

SPARE PEEK FERRULES AND NUTS FOR ASX(-c) AUTOSAMPLER

SPARE PARTS PASTECELL N

PASTECELL N WINDOWS FOR 120 °C (30 Pcs.)

PASTECELL N WINDOWS FOR 300 °C (30 Pcs.)

SPARE PARTS SAXSpoint 5.0 HOUSING

QUARTZ CUVETTE 1 mm FOR TCS Sample holder with 1 mm quartz capillary for measurements of

Temperature-Controlled Sample Stages:
TCStage
- Temperature-controlled sample stages for single samples
- Dedicated sample holders for liquids, solids, pastes, and gels
- Special sample holders e.g. for sample spinning, under pressure, and for disposable capillaries
- Temperature range from -150 °C to +600 °C

Heated Sampler
- Temperature-controlled sample stages for Anton Paar’s SAXSpoint systems
- Automatic scans on up to 20 solid, liquid, and paste/gel-like samples
- Heated/Cooled Sampler: from -10 °C to 120 °C
- Heated Sampler 2.0: from -150 °C to 350 °C

Bonse-Hart USAXS Camera:
USAXS Module
- Automatic USAXS, SAXS, and WAXS studies using a fully motorized experimental setup
- Probing structures from the nanometer to the micrometer level
- Simultaneous and precise (± 0.1 °C) sample temperature control

Autosampler:
ASX
- High sample throughput of up to 192 samples from 96 well plates
- High-precision injection down to 10 µL sample volume
- Compatible with all Anton Paar flow-through cells: Flow Cell, Tube Cell, SiN Cell
- Minimal bench space required

GISAXS Stage 2.0
- Investigation of nanostructured surfaces and thin film samples
- Ideal for mesoporous thin films, surface-deposited nanoparticles, metal deposits on oxide surfaces, soft matter systems, and biological materials attached to surfaces
- Samples can be tilted and rotated

Tensile Stage 2.0
- The only commercially available stage specially designed for in-situ SWAXS studies of stress/strain phenomena
- For investigating fibers, foils, and thin films
- Studies at forces between 0.01 N and 600 N
- Temperature range from -150 °C to +350 °C

Humidity Stage
- For temperature- and humidity-dependent SAXS and WAXS studies of nanostructures
- Ideal for investigating the influence of temperature and humidity on powders and thin films
- Studies in vacuum, air, and inert gas from 10 °C up to 110 °C

Combined Rheology and SAXS Setup:
RheoSAXS Module
- Study structural and rheological properties simultaneously
- Measure parallel or perpendicular to flow direction
- All existing SAXSpoint instruments can be upgraded with this module