Density meter:
DMA 4100 M

  • Measure density and concentration at 4-digit accuracy
  • Only 30 seconds per measurement for high-throughput quality control
  • The first choice for petroleum sample measurement according to ASTM standards
Online price only | excl.incl. 0VAT
Price
upon request
Purchasable online
in specific countries
Buy Anton Paar instruments online
Part number: 153058
Check online availability Get a quote Buy this product online
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months

DMA 4100 M delivers the 4-digit density values you need and is not affected by your working environment and workforce. It applies the patented Pulsed Excitation Method to deliver the most stable density results based on comprehensive knowledge of the oscillation characteristics. This method results in viscosity correction which is twice as effective as anything else available on the market. The integrated camera allows you to check the filling procedures of your operators at any time and also at the end of the working day. The patented condition monitoring ensures that frequently changing users with differing filling approaches, humidity, temperature fluctuations, air pressure, and instrument condition all have no effect on the operation and results – built-in intelligence for your convenience. 

Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
HR
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
Asia-Pacific
Australia
EN
China
ZH
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
TH
If you can't find your country in the list get a quote

Key features

A revolutionary density measuring principle for quick and easy quality control

The unique design of the measuring cell, a novel way of evaluating the oscillation characteristics, and many other innovative features lead to the following:

Unaffected by harsh working conditions

Unaffected by harsh working conditions

  • Stable results under varying conditions, such as humidity, temperature and air pressure
  • Housing withstands shocks, dirt, and spillages
  • Frequently changing users and filling styles do not influence the measurement results 
Supervise all filling procedures and be alerted if there is an error

Supervise all filling procedures and be alerted if there is an error

  • The U-View™ camera feature displays and stores live images of the oscillating U-tube sensor and the entire filled-in sample
  • Relevant images with the sample fully and clearly visible are stored in the data memory 
  • Later review of these images guarantees completely transparent measurement processes
Automatic bubble detection

Automatic bubble detection

  • Monitor your sample handling with the FillingCheck™ that detects filling errors, gas bubbles and particles in the sample 
  • FillingCheck™ generates and records filling warnings
  • U-View™ and FillingCheck™ supervise the entire measurement sequence and allow later verification of the results, which is particularly useful when using automatic sampling systems
Touchscreen for premium user experience

Touchscreen for premium user experience

  • The only density meter with PCAP touchscreen technology for unmatched sensitivity and robustness at the same time
  • Easy operation, even when wearing gloves
  • Large screen, readable from a distance due to adaptable font sizes

Technical specifications

DMA 4100 M DMA 4500 M DMA 5000 M
Patents granted
  • AT 516420 (B1)
  • AT 517082 (B1)
  • AT 516420 (B1)
  • AT 517082 (B1)
  • AT 516420 (B1)
  • AT 517082 (B1)
Patents pending
  • AT 517486 (A1)
  • AT 517486 (A1)
  • AT 517486 (A1)
Measuring range
  • Density: 0 g/cm³ to 3 g/cm³
  • Temperature: 0 °C to 100 °C
    (32 °F to 212 °F)
  • Pressure: Up to 10 bar (145 psi)
  • Density: 0 g/cm³ to 3 g/cm³
  • Temperature: 0 °C to 100 °C
    (32 °F to 212 °F)
  • Pressure: Up to 10 bar (145 psi)
  • Density: 0 g/cm³ to 3 g/cm³
  • Temperature: 0 °C to 100 °C
    (32 °F to 212 °F)
  • Pressure: Up to 10 bar (145 psi)
Repeatability s.d.(1)
  • Density: 0.00001 g/cm³
  • Temperature: 0.02 °C/0.04 °F
  • Density: 0.000005 g/cm³
  • Temperature: 0.01 °C/0.02 °F
  • Density: 0.000001 g/cm³
  • Temperature: 0.001°C/0.002°F
Reproducibility s.d.(1)
  • Density: 0.00005 g/cm³
  • Density: 0.00002 g/cm³
  • Density: 0.000005 g/cm³
Accuracy(2)
  • Density: 0.0001 g/cm³
  • Temperature: 0.03 °C/0.05 °F
  • Density: 0.00005 g/cm³ 
  • Temperature: 0.02 °C/0.04 °F
  • Density: 0.000007 g/cm³ 
  • Temperature: 0.01 °C/0.02 °F
Digital Resolution
  • 0.0001 g/cm³
  • 0.00001 g/cm³
  • 0.000001 g/cm³
Integrated tables and functions
  • Alcohol tables
  • Extract/sugar tables
  • API functions
  • Acid/base tables
  • 150 freely programmable tables/user functions (tables, polynomials, formulas, linear functions, and constants)
  • Alcohol tables
  • Extract/sugar tables
  • API functions
  • Acid/base tables
  • 150 freely programmable tables/user functions (tables, polynomials, formulas, linear functions, and constants)
  • Alcohol tables
  • Extract/sugar tables
  • API functions
  • Acid/base tables
  • 150 freely programmable tables/user functions (tables, polynomials, formulas, linear functions, and constants)
Minimum sample amount
  • approx. 1 mL
  • approx. 1 mL
  • approx. 1 mL
Measuring time per sample(3)
  • 30 seconds
  • 30 seconds
  • 40 seconds
Dimensions (L x W x H)
  • 495 mm x 330 mm x 230 mm
    (19.5 in x 13 in x 9.1 in)
  • 495 mm x 330 mm x 230 mm
    (19.5 in x 13 in x 9.1 in)
  • 495 mm x 330 mm x 230 mm
    (19.5 in x 13 in x 9.1 in)
Data memory
  • 1000 measurement results
    (optional ring memory)
  • 1000 measurement results
    (optional ring memory)
  • 1000 measurement results
    (optional ring memory)
Power supply
  • AC 100 to 240 V
  • 50 to 60 Hz
  • 190 VA
  • AC 100 to 240 V
  • 50 to 60 Hz
  • 190 VA
  • AC 100 to 240 V
  • 50 to 60 Hz
  • 190 VA
Weight
  • 22.5 kg
    (49.6 lbs)
  • 22.5 kg
    (49.6 lbs)
  • 22.5 kg
    (49.6 lbs)
Interfaces
  • 4 x USB
  • RS-232
  • CAN
  • VGA
  • Ethernet
  • 4 x USB
  • RS-232
  • CAN
  • VGA
  • Ethernet
  • 4 x USB
  • RS-232
  • CAN
  • VGA
  • Ethernet
Display
  • Bright 10.4" TFT PCAP touchscreen (640 x 480 px) with customizable display layout
  • Bright 10.4" TFT PCAP touchscreen (640 x 480 px) with customizable display layout
  • Bright 10.4" TFT PCAP touchscreen (640 x 480 px) with customizable display layout
Wetted parts
  • PTFE, borosilicate glass
  • PTFE, borosilicate glass
  • PTFE, borosilicate glass
Industries
  • Beverages
  • Chemical Industry
  • Cosmetics, Personal Care
  • Electronics
  • Environmental
  • Food Industry
  • Petroleum Industry
  • Pharmacy, Medicine, Biotechnology
  • Beverages
  • Chemical Industry
  • Cosmetics, Personal Care
  • Education, Research
  • Electronics
  • Environmental
  • Food Industry
  • Petroleum Industry
  • Pharmacy, Medicine, Biotechnology
  • Beverages
  • Chemical Industry
  • Cosmetics, Personal Care
  • Education, Research
  • Electronics
  • Environmental
  • Pharmacy, Medicine, Biotechnology

(1) according to ISO 5725

(2) under ideal conditions and for low densities/viscosities

(3) After temperature equilibration

Standards

2020 Chinese Pharmacopoeia

0601-relative density determination method

ABNT

NBR 14065
NBR 15639

AOAC

982.10

ASBC

Beer-2B: Specific Gravity by digital density meter (1978)
Beer-5: Real Extract (B. Beer measured gravimetrically (1958), C. Real Extract determined refractometrically (1982))

ASTM

D1250
D1475
D2501
D4052
D4806
D5002
D5931
D6448

CPTC

SH/T 0604-2000 eqv. ISO 12185

DIN

51757

EBC

Chapter 1.6
Chapter 8.2.2
Chapter 9.43.2

European Union

Spirits drinks: COMMISSION REGULATION (EC) No 2870/2000
Wines: COMMISSION REGULATION (EC) No 128/2004
Wines: COMMISSION REGULATION (EC) No 355/2005
Wines: COMMISSION REGULATION (EEC) No 2676/90

GB

23971
T 2013-2010
T 11540-2008
T 13531.4-2013
T 21862.3
T 22731
T 29617

HG

T 4067

HM Revenue & Customs

Density measurement for the revenue accounting of spirits

IP

365

ISO

2811-3
12185
14214
15212-1
18301

JIS

K 0061
K 2249

JJF

1070

OIML

R 22

OIV

Alcohol content in wine and musts
Analysis method for density measurement in wine and musts
MA-BS-04
MA-BS-06

Ph. Eur.

2.2.5 - Relativ density

QB

T 1858.1
T 2660

RANP

5
19
20
30
40
45
50
52
58
71
669
764
778
807

SH

0604-2000

USP

29 - Specific Gravity Method II
841 - Specific gravity

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Accessories & Software

Your choice: Reset all filters X
Industry
Applications
Standards
Showing to of

Similar products

Consumables

Consumables are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

Check online availability
Online price only | excl.incl. 0VAT

ADAPTER LUER CONE

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 63863

ADAPTER UNF 1/4"-LUER MALE

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 64793

COLORSTANDARD CA.50EBC 5X50ML

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 12627

DENSITY STANDARD "CAESIUM CHLORIDE" 10ML

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 15542

DENSITY STANDARD "OCEAN SEAWATER"

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 159213

DENSITY STANDARD "OIL 8cSt@40°C"

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 13633

DENSITY STANDARD "SODIUM BROMIDE" 10ML

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 15541

DENSITY STANDARD "TRIMETHYLPENTA" 10ML

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 302953

Density Standard "Ultra Pure Water"

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 70394

Density standard Dextrose/Water (10%W/W)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 13651

Density standard Ethanol/Water (11% ABV)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 13640

Density Standard Seawater

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 156636

Density std Ethanol/Water (~41% ABV)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 13639

FOIL CABLE DCB => CAM

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 44169

Isoversinic Tubing I.D.=2 O.D.=4

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 54628

MALE LUER PLUG PTFE

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 63865

Printer EPSON TM-U220D for DMA G. M

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 93362

PRINTER CONNECTION CABLE

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 64433

Set of caps D14 (30Pcs.) Silicone

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 25175

Set of caps D29 (30Pcs.) silicone

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 16031

Silicone Tubing I.D.=3 O.D.=5

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 50814

Syringe 10 mL Luer-Lock two-part

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 10054

SYRINGE 2ml LUER (1 PCS)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 51974

Syringe 5 mL Luer-Lock two-part

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 152551

SYRINGES 2 ml LUER (10 PCS)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 58802

SYRINGES 2 ml LUER (1000 PCS)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 66399

Syringes 5 ml Luer (100 pcs.)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 6772

Versilic Silicone Tubing I.D.=4 O.D.=6

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 57024

Vial 12mL glass (100 Pcs.)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 94197

Vial 50mL polystyrene (50 Pcs.)

Get a quote
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Get a quote
Part number: 12224