Dissolved Gas Measuring Module:
CarboQC ME
- Selective CO2 determination
- Automatic filling check
- For all types of carbonated beverages
- Optional module for simultaneous determination of dissolved O2
The combined CO2 and O2 measuring module CarboQC ME with Option O2 (Plus) determines the true amount of dissolved CO2 and O2 in beverages. Add Option O2 (plus) to a CarboQC ME and combine it with a wide range of Anton Paar instruments for thorough beverage analysis in a single measuring cycle. Degassing prior to analysis is not necessary, reducing your workload to a minimum and eliminating potential errors resulting from sample preparation. The module doesn’t just deliver results in only 90 sec, it also saves space in the lab. For use only with Anton Paar’s Packaged Beverage Analyzers.
Key features
Selective measurement: Obtain the true amount of dissolved CO₂ and O₂
- CO2 measurement using patented Multiple Volume Expansion method guarantees repeatability standard deviations of 0.005 vol
- Highly repeatable O2 results (2 ppb) because of optical oxygen sensor
- No influence from other dissolved gases such as air or nitrogen
Automatic parameter correction
- Reliable CO2 and O2 results, even out of small packages with a sample volume of only 150 mL
- Use of the measured CO2 content to automatically correct parameters such as density to match your reference method – degassing is not required
- PFD filling device transfers samples from package to measuring chamber with zero CO2 and O2 loss
TPO check included
- Total package oxygen (TPO) value calculable via Option O2 (Plus) in Anton Paar’s Packaged Beverage Analyzers.
Fit for the future
- The standard beverage analysis configuration with the benchtop DMA density meter, CarboQC ME, and a PFD filling device is a solid investment.
- Anton Paar’s modular concept allows flexible extension of measuring modules, e.g. for alcohol, pH, or turbidity.
- Create your very own system based on your requirements
Technical specifications
Measuring range | ||
CO2 | 0–12 g/L (0–6 vol.) at 30 °C (86 °F) 0–20 g/L (0–10 vol.) < 15 °C (59 °F) | |
O2 | 0–4 ppm | |
Temperature | –3 to 40 °C (27 to 104 °F) | |
CO2 measurement | ||
Repeatability, s.d. | 0.01 g/L (0.005 vol.) CO2 | |
Reproducibility, s.d. | 0.05 g/L (0.025 vol.) CO2 | |
O2 measurement | ||
Repeatability, s.d. | 2 ppb (in the range < 200 ppb) | |
Reproducibility, s.d. | 4 ppb (in the range < 1000 ppb) 10 ppb (in the range 1000–2000 ppb) 20 ppb (in the range 2000–4000 ppb) | |
Response time of the oxygen sensor at 25 °C (77 °F) (from air to nitrogen) | 98 % of the final value in less than 30 s | |
Additional information | ||
Sample volume | approx. 150 mL for similar samples | |
Dimensions (L x W x H) Option O2 incl. CarboQC ME: Option O2 Plus incl. modular stand and PFD (Plus): | 320 mm x 120 mm x 330 mm (12.6 in x 4.7 in x 13.0 in) 200 mm x 348 mm x 670 mm (7.9 in x 13.7 in x 26.4 in) | |
Weight Option O2 incl. CarboQC ME: Option O2 Plus: | approx. 3.7 kg (8.2 lbs) approx. 0.35 kg (0.77 lbs) | |
Power | supplied by the master instrument | |
Interfaces | 2 x CAN |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Beverage | Beer | Complete your Beer Analysis Application Reports
-
Beverage | Wine | Complete your wine analysis Application Reports
-
Brochure | Beer analysis overview Brochures
-
Brochure | CO2 / O2 / TPO meter series Brochures
-
Brochure | Soft drink analysis overview Brochures
-
publication_TPO: Getting the Whole Picture Customer Reports and Publications
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
OXYGEN SENSOR CAP VISIBEV DO 120 FOR REPLACEMENT
CAN/DEVICENET TERMINATING RESISTOR 5-POLES
RUBBER FOOT 3.5x12.7