Dynamic Shear Rheometer:
SmartPave
- Rheometer for research and development of asphalt and bitumen
- Illuminated sample area for perfect trimming results
- Upgradeable for tests on solid mastic materials
- Suitable for measurements of rubber-modified bitumen and at low temperature ranges down to -50 °C
The dynamic shear rheometers (DSR) SmartPave 92 and SmartPave 303 enable the performance of precise measurements on asphalt binder and bitumen. Features such as Toolmaster, QuickConnect, a Peltier temperature device for dry sample heating, and step-by-step instructions for measuring procedures according to AASHTO T315, AASHTO T350, AASHTO TP101, ASTM D7175, ASTM D7405, and DIN EN 14770 guarantee convenient operation. For measurements according to AASHTO T316, ASTM D4402, and DIN EN 13302, both instruments can be equipped with a Peltier-controlled measurement chamber for concentric cylinder geometries.
Get Our Latest Bitumen Rheology Book
Interested in learning more about the flow and deformation behavior of bitumen in an easy, entertaining way? Then join Joe Flow and Samira Smart on the Bitumen Rheology Road.
Order now
Key features
Two models for the whole spectrum of rheological asphalt and bitumen testing
The well-established SmartPave dynamic shear rheometers analyze unmodified and modified asphalt binder and bitumen within a wide temperature range, either according to standards or by means of classic rheological methods. SmartPave 303 meets the highest measurement demands across the board. SmartPave 92 is designed especially for the demands of quality control and routine measurements in asphalt test labs.

RheoCompass software
RheoCompass is a navigation tool that provides both a complete overview and detailed insights. It contains numerous templates tailored specifically to using the dynamic shear rheometer in the asphalt industry. The predefined test procedures include step-by-step instructions for all test types as defined by AASHTO, ASTM, DIN EN, and FGSV. Templates are regularly updated to ensure you always comply with the latest version of your standard.

Unique accessories for easy handling
The unique temperature control unit of SmartPave 92 and SmartPave 303 is the first Peltier heating system with heating elements above and below the sample – combined with the widest temperature range. Both instruments also include Toolmaster. The only completely contact-free automatic tool recognition and configuration system for rheometers, it recognizes measuring systems and temperature control units as soon as they are connected to the rheometer, eliminating the need for manual data entry.

Fully automatic temperature calibration
Temperature accuracy and stability are crucial in asphalt testing. Anton Paar offers fully automatic temperature calibration and verification routines via the RheoCompass software. The unique automatic calibration routine ensures temperature gradients <0.1 °C, tailored specifically for asphalt workflows using the SmartPave dynamic shear rheometer.

Upgrade your SmartPave DSR to a BBR
Enhance your SmartPave 303 or 92 with a specialized software solution from our cooperation partner, Pavement Systems LLC. Connect effortlessly to this external analysis software and unlock a range of features, including iCCL testing. This powerful surrogate method to BBR (AASHTO PP112) provides low-temperature PG grade, m-value, stiffness (S), and ΔTc results – all within 30 minutes. Learn more about Pavement Systems and their analysis solutions.

Experienced experts on hand
Anton Paar’s worldwide service network ensures that an expert on your system is always nearby. Numerous installed instruments around the globe, an extensive application database, and cooperation with civil engineering institutes underscore that Anton Paar is the number one choice for answers to rheological questions about asphalt binder and bitumen.

Specifications
Technical Data | Unit | SmartPave 92 | SmartPave 303 |
Bearing design | - | Air, fine-pored carbon | |
Motor design | - | Electronically Commutated (EC) - Permanent Magnet Synchronous Motor | |
Displacement transducer design | - | High-resolution optical encoder | |
Normal force measurment design (US Pat. 6167752,1996) | - | - | 360 ° capacitive sensor, non-contacting, fully integrated in bearing |
Working mode | - | Combined Motor Transducer (CMT) | |
Minimum torque (rotation) | nNm | 0.4 µNm | 5 |
Minimum torque (oscillation) | nNm | 0.4 µNm | 1 |
Maximum torque | mNm | 125 | 215 |
Minimum angular deflection (set value) | µrad | 1 | 0.5 |
Maximum angular deflection (set value) | µrad | ∞ | ∞ |
Minimum angular velocity[1] | rad/s | 0 | 0 |
Maximum angular velocity | rad/s | 157 | 314 |
Maximum speed | 1/min | 1500 | 3000 |
Minimum speed (CSS/CSR) | 1/min | 10-3 | 10-7 |
Minimum angular frequency[2] | rad/s | 10-4 | 10-7 |
Maximum angular frequency | rad/s | 628 | 1256 |
Maximum frequency[3] | HZ | 100 | 200 |
Normal force range | N | - | -50 to 50 |
Normal force sensitivity | N | - | 0.001 |
Minimum gap size change | µm | 0.625 | 0.0625 |
Dimensions (W x H x D) | mm | 380 x 660 x 530 | 453 x 725 x 673 |
Weight | kg | 33 | 48 |
Additional Device Features | |||
Device display with remote control of software (decoupled from measuring sensor for mechanical and electromagnetic interference prevention) | - | Yes | Yes |
Direct strain/stress controller | - | Yes | Yes |
TruStrain™ (sample adaptive controller) | - | No | Yes |
TruRate™ (sample adaptive controller) | - | No | Yes |
Raw data (LAOS, waveform) | - | No | Yes |
Normal force profiles (set and read) | - | No | Yes |
Velocity profiles, tack, squeeze | - | No | Yes |
Automatic gap control/setting (AGC/AGS) | - | Yes | Yes |
Electronic trim lock for measuring geometry | - | Yes | Yes |
Toolmaster™ (measuring geometries and accessories, storing of zero-gap) (US Pat. 7275419, 2004) | - | Yes | Yes |
QuickConnect Coupling for measuring geometries (one-hand operation, screwless) | - | Yes | Yes |
Trimming mirror (360° blind sample spot prevention) | - | No | Yes |
Three-point support of device (three robust feet for tool-free one hand alignment) | - | Yes | Yes |
Three-point support for mounting of measuring cells (wobble prevention, no misalignment after changing of cells) | - | Yes | Yes |
Maximum temperature range[4] | °C | -50 to +400 | -160 to +1000 |
Virtually gradient-free temperature control (horizontal,vertical) | - | Yes | Yes |
Temperature gradient >0.1 °C according to AASHTO and ASTM | - | Yes | Yes |
CoolPeltier™ Peltier System with built-in cooling option that does not require additional accessories for counter cooling | °C | -5 to +200 | -5 to +200 |
Pressure Cell | bar | No | up to 1000 |
Safe Gap™ normal force limiter during gap setting | - | Yes | No |
TruRay™ dimmable illumination of sample area | - | Yes | Yes |
RheoCompass Software | |||
Asphalt standard operation procedures (SOP) with regular updates | - | Yes | Yes |
Auto Update via Network | - | Optional | Optional |
Fully automatic temperature calibration | - | Yes | Yes |
Test and analysis designer | - | Yes | Yes |
Report designer (with all test information for export and print) | - | Yes | Yes |
Managed lab multiple clients and servers | - | Optional | Optional |
1. In controlled shear stress (CSS) mode. In controlled shear rate (CSR) mode, depending on measuring point duration and sampling rate.
2. Theoretical value (duration per cycle = 2 years)
3. Higher frequencies are possible using multi-wave functionality (942 rad/s (150 Hz) or even higher, depending on measuring system and sample)
4. Depending on used temperature device
Standards
AASHTO
ASTM
DIN EN
FGSV
IS
SATS
AGPT
GOST
Standards
AASHTO
ASTM
DIN EN
FGSV
IS
SATS
AGPT
GOST
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
3-PB of Bitumen Using a Rheometer Equipped with an Additional Lower Linear Drive Application Reports
-
Behavior of bitumen in the temperature range of -6 °C to +90 °C Application Reports
-
E-Book - Field Guide to Battery Materials Characterization – Revised and Updated Application Reports
-
E-Book - Field Guide to Food Powder Characterization Application Reports
-
E-Book - Field Guide to Food and Feed Testing Application Reports
-
E-Book - The Field Guide to Pharmaceutical Powder Characterization Application Reports
-
E-Book - The Future of Plant-Based Foods Application Reports
-
Instructions for FGSV 722 Application Reports
-
not available in English - FGSV 720 - Bitumen-Typisierungs-Schnell-Verfahren Application Reports
-
not available in English - FGSV 723 - Multiple Stress Creep Recovery Test Application Reports
-
Pave your way - Asphalt Flyer Brochures
-
Conformity SmartPave 92 AASHTO, ASTM, ... Certificates
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.

INSET I-PP50/CU/CX D:
50 mm, COPPER ALLOY, CERID COATING
SmartPave 92

SILICON MOLD FOR ASPHALT BINDER (PP08) ACCORDING AASHTO T315
SmartPave 92

MEAS. PLATE PP08/PE FOR X2/XX2
SmartPave 92
D: 8 mm

MEAS. PLATE PP25/PE FOR X2/XX2
SmartPave 92
D: 25 mm

MEASURING PLATE PP08/SP FOR X2/XX2
SmartPave 92
D: 8 mm

MEASURING PLATE PP25/SP FOR X2/XX2
SmartPave 92
D: 25 mm

Temperature Control for MCR:
Peltier Systems
SmartPave 92 | 303
- Effective and convenient heating and cooling
- Air cooled Peltier hood and plate; sustainable and cost efficient
- Temperature control with minimized temperature gradients from -50 °C to +220 °C
- Modular system for combination with rheo-optics accessories
- For cone-plate, parallel-plate, and cylinder measuring systems

DISPOSABLE MEAS. CUP D-C-CC27/AL ALUMINIUM, 1 pack = 100 pcs
SmartPave 92 | 303

FILTER ELEMENT FOR CLEARPOINT FINE FILTER 10660
SmartPave 92 | 303

FILTER ELEMENT FOR CLEARPOINT MICRO FILTER 10661
SmartPave 92 | 303

SILICON MOLD FOR ASPHALT BINDER (PP25) ACCORDING AASHTO T315
SmartPave 92 | 303

INSET I-PP08/CU/CX (WITH GROOVE) D:
8 mm, COPPER ALLOY, CERID COATING
SmartPave 92 | 303

INSET I-PP25/CU/CX D:
25 mm, COPPER ALLOY, CERID COATING
SmartPave 92 | 303

MEAS. CYLINDER B-CC27 FOR X2/XX2
SmartPave 92 | 303
D: 26.66 mm

VISCOSITY STANDARD ANTON PAAR S3 (L) 500 ml - 3.7 / 2.3 / 0.9 mPa.s
SmartPave 92 | 303

VISCOSITY STANDARD ANTON PAAR N7.5 (M) 500 ml - 10 / 5.4 / 1.6 mPa.s
SmartPave 92 | 303

VISCOSITY STANDARD ANTON PAAR N26 (C) 500 ml - 50 / 21 / 4.2 mPa.s
SmartPave 92 | 303

VISCOSITY STANDARD ANTON PAAR N415 (H) 500 ml - 1100 / 330 / 32 mPa.s
SmartPave 92 | 303