Cryo & Humidity Chamber:
CHC plus⁺
- Condensation-free experiments under rel. humidity and temperature
- Overall temperature range from -180 °C to +400 °C;
Controlled relative humidity studies from 10 °C to 80 °C - Easy changeover from low-/high-temperature experiments to humidity measurements without opening the chamber
CHC plus+ is a unique combination of the multi-purpose CHC Cryo & Humidity Chamber and an advanced humidity (RH) generator for the analysis of humidity-dependent and/or temperature-dependent structural changes in materials using X-ray diffraction. Investigations into pharmaceuticals, fine chemicals, clays or zeolites can be carried out in humid gas, air, inert gas or vacuum. Controlled humidity is possible for sample temperatures from 10 °C to 80 °C. Due to its versatility, the new combined CHC plus+ setup opens new dimensions in analysis for materials science and is a true "workhorse" for the pharmaceutical industry.
Key features
Defined temperature and environmental conditions
- Computer-controlled temperature control unit and RH generator
- Fast, accurate, and stable temperature control
- Well-defined, uniform humidity conditions around the sample
- Gas humidifier on the CHC lid and temperature-controlled chamber housing prevent any condensation problems
Reliable monitoring of the sample environment
- Precise Pt100 temperature sensor for temperature measurement and control
- Calibrated RH sensor close to the sample and new humidity generator guarantee accurate humidity control
- Sample temperature range from –180 °C to +400 °C with liquid nitrogen cooling, and from –5 °C to +400 °C with compressed air cooling
Optimal for analyzing organic materials
- Easy changeover from low/high-temperature experiments to humidity measurements without opening the chamber
- Integrated beam knife for measurement at low 2Θ angles
- Easy mounting and exchange of samples without realignment
- Sample holders with various depths and zero background option
Technical specifications
Operating temperature with compressed air cooling | Vacuum (10-2 mbar): -5 °C to 400 °C; air ; inert gas: -5 °C bis 300 °C; humid gas: 10 °C bis 80 °C |
---|---|
Operating temperature with liquid nitrogen cooling | Vacuum: -180 °C to 400 °C Air, dry nitrogen: -120 °C to 300 °C |
Relative humidity range | 5 to 95 % RH at 10 °C to 60 °C 5 to 70% RH at 80 °C |
Temperature measurement | Pt 100 |
Atmospheres | (Humid) air/nitrogen, inert gas, vacuum (10-2 mbar) |
Scan range | 0 bis 164° 2θ |
Max. operating pressure | 0.2 bar above atmospheric pressure |
Sample holder surface | Copper, chromed |
Sample cavity area | 10 x 14 mm |
X-ray geometry | Reflection |
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
E-Book - Field Guide to Pharmaceutical Powder Characterization Application Reports
Compatible instruments
Consumables
Consumables
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
SET OF KAPTON FOILS FOR CHC plus+ (5 pcs.)
SET OF GRAPHITE FOILS FOR CHC plus+ (5 pcs.)
SET OF HEAT CONDUCTING GRAPHITE FOILS FOR CHC plus+ (10 pcs.)
NON-AMBIENT GUIDE