Medical samples & biomaterials, membranes

Opening up new channels for biomaterials engineering and research

Research on biomaterials, membranes, and medical samples requires high-precision tools which are reliable and intuitive to use. Whether you are investigating chemical processes, the behavior of particles, mechanical or elastic behavior or permeability, Anton Paar has a solution for you. 

Get in touch

Anton Paar Products

Type of operation
Standards
Product group
Device type
Your choice : Reset all filters

No results found!

Automated Multipurpose Powder X-Ray Diffractometer:
XRDynamic 500
Benchtop Density Meter:
DMA
Benchtop Refractometer:
Abbemat Essential 3001
Benchtop Refractometer:
Abbemat Essential 3101
Benchtop Refractometer:
Abbemat Essential 3201
Bioindenter:
UNHT³ Bio
Capillary Flow Porometers for Through-Pores:
Porometer 3G
Capillary Flow Porometers for Through-Pores:
Porometer 3G micro
Capillary Flow Porometers for Through-Pores:
Porometer 3G z
Capillary Flow Porometers for Through-Pores:
Porometer 3G zH
Dual Wavelength Compact Raman Spectrometer:
Cora 5001 Direct Pharma
Dual Wavelength Compact Raman Spectrometer:
Cora 5001 Direct Standard
Dual-Wavelength In-Situ Raman Spectrometer:
Cora 5001 Fiber Pharma
Dual-Wavelength In-Situ Raman Spectrometer:
Cora 5001 Fiber Process Monitoring
Dual-Wavelength In-Situ Raman Spectrometer:
Cora 5001 Fiber Standard
Dynamic Image Analyzer:
Litesizer DIA
Dynamic Image Analyzer:
Litesizer DIA 100
Dynamic Image Analyzer:
Litesizer DIA 500
Dynamic Image Analyzer:
Litesizer DIA 700
Dynamic Light Scattering Instrument:
Litesizer DLS
Dynamic Light Scattering Instrument:
Litesizer DLS 101
Dynamic Light Scattering Instrument:
Litesizer DLS 501
Dynamic Light Scattering Instrument:
Litesizer DLS 701
Dynamic Mechanical Analyzer:
MCR 702e MultiDrive
Dynamic Shear Rheometer Measuring Head:
DSR 502
Electrokinetic Analyzer for Solid Surface Analysis:
SurPASS 3 Eco
Electrokinetic Analyzer for Solid Surface Analysis:
SurPASS 3 Standard
Entry-Level Rheometer:
MCR
FTIR Spectrometer:
Lyza
FTIR Spectrometer:
Lyza 3000
FTIR Spectrometer:
Lyza 7000
Gas Pycnometer for Semi-Solid and Solid Density:
Ultrapyc
High Vacuum Physisorption Analyzer:
Autosorb
High Vacuum Physisorption Analyzer:
Autosorb 6100
High Vacuum Physisorption Analyzer:
Autosorb 6200
High Vacuum Physisorption Analyzer:
Autosorb 6300
High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
High-Pressure Volumetric Gas Sorption Analyzer:
iSorb
High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
High-Pressure Volumetric Gas Sorption Analyzer:
iSorb HP1 100
High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
High-Pressure Volumetric Gas Sorption Analyzer:
iSorb HP1 200
High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
High-Pressure Volumetric Gas Sorption Analyzer:
iSorb HP2 100
High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
High-Pressure Volumetric Gas Sorption Analyzer:
iSorb HP2 200
Inline Density Meter:
L-Dens 7400
Inline Density Meter:
L-Dens 7500
L-Rix inline refractometer with a stainless steel housing, one unit showing the sensor side and the other displaying measurement data on a digital screen.
Inline Refractometer:
L-Rix
Mechanical Surface Testing Platforms:
Step
Mercury Intrusion Pore Size Analyzers:
PoreMaster
Mercury Intrusion Pore Size Analyzers:
PoreMaster 33
Mercury Intrusion Pore Size Analyzers:
PoreMaster 60
Mercury Intrusion Pore Size Analyzers:
PoreMaster 60GT
Micro Combi Tester:
MCT³
Microwave Digestion Platform:
Multiwave
Microwave Digestion System:
Multiwave GO Plus
Microwave Reactor:
Monowave
Microwave Reactor:
Monowave 200
Microwave Reactor:
Monowave 400
Microwave Reactor:
Monowave 450
Modular Compact Rheometer:
MCR 702e MultiDrive
Modular Compact Rheometer:
MCR 702e Space MultiDrive
Modular Compact Rheometer:
MCR 102e/302e/502e
Nano Scratch Tester:
NST³
Nanoindentation Tester:
NHT³
Pin-on-disk tribometer:
TRB³
Portable Density Meter:
DMA 35 Standard
Side-by-side view of the Anton Paar Revetest® Scratch Tester RST 100 and RST 300, displaying the control heads, indenters, and testing bases for material surface testing.
Revetest Scratch Tester:
RST
Rheometer Automation for High Sample Throughput and Complex Sample Handling:
HTR
Rheometer-Raman Setup:
MCR Evolution & Cora 5001
Rotational Rheometer:
RheolabQC
SAXS/WAXS System:
SAXSpoint 500
SAXS/WAXS System:
SAXSpoint 700
SAXS/WAXS/BioSAXS System:
SAXSpace
Ultra Nanoindentation Tester:
UNHT³
Vacuum and Flow Degasser:
FloVac
High Temperature Vacuum Tribometer
Vacuum Tribometer:
TRB V / THT V
Vapor Sorption Volumetric Gas Sorption Analyzer:
VSTAR 2 Station
Vapor Sorption Volumetric Gas Sorption Analyzer:
VSTAR 2 Station Turbo
Vapor Sorption Volumetric Gas Sorption Analyzer:
VSTAR 4 Station
Vapor Sorption Volumetric Gas Sorption Analyzer:
VSTAR 4 Station Turbo

Differentiating between normal and pathological red blood cells

Anton Paar’s MCR rheometer is an excellent tool for monitoring the rheological characteristics of whole blood. At low shear stress, for example, red blood cells adhere to each other, aggregate, and form rouleaux. Using an MCR with a microscope accessory allows you to monitor changes in blood under various conditions through the microscope lens during the measurement. This combined information enables the correlation of the rheological properties of red blood cells to their aggregation state. Whole blood samples can be investigated according to the Recommendation of the International Committee for Standardization in Hematology.

Investigating the fouling of membranes and improving their biocompatibility

An economical and effective adsorbent for low-density lipoprotein (LDL) in blood is a dialysis membrane which is based on polysulfone with covalently bound heparin. However, problems inherent in the applicability of membranes in hemodialysis are surface-induced blood coagulation and membrane fouling due to irreversible protein adsorption. To improve the biocompatibility of these hemodialysis membranes, the inner surface of the membrane requires modification. A major challenge inherent to this process is the permanent coating with heparin. The grafting of reactive groups onto the polysulfone surface is one route to prepare the interface for the immobilization of such biologically active substances. The SurPASS electrokinetic analyzer is applied for analyzing the inner surface of such hollow-fiber membranes. Comparing the zeta potential of untreated and modified membranes reveals the efficiency of the surface treatment. The isoelectric point, which is obtained automatically, and the zeta potential values at higher pH are an indication that the grafting of reactive groups and the coating with heparin were successful.

Ensuring the safety of IV infusions

A common risk from intravenous infusions is contamination by particles that are not visible to the eye. To detect these unwanted particles and monitor the quality of IV infusions requires an analyzer such as Anton Paar’s Litesizer 500 which determines the particle size and particle size distribution of a solution quickly and from very small sample amounts (from 12 µL). The measurement meets the requirement of the US Pharmacopoeia for parenteral products which defines the size of droplets in emulsions and solutions to be infused or injected.

Assessing the level of trace elements in urine, blood, and hair

Evaluating trace element concentrations using, for example, ICP-MS/ICP-DRCMS and ETAAS requires sample solutions which are completely digested in order to minimize spectral and matrix interferences in the measurement. Microwave-assisted pressure digestion provides one such reliable method of sample preparation. Multiwave PRO, for example, decomposes body fluids and hair to produce high-quality samples in a short period of time. 

Webinars

We offer you a great and constantly growing choice of live webinars and recordings on products, applications, and scientific topics.

Show more

Application Reports

Explore our database of application reports and find out how to overcome challenges in your field.

Show more