Dynamic Image Analyzer:
Litesizer DIA
- Measure samples between 0.8 µm and 8,000 µm and even detect and analyze single particles
- Use the operating software Kalliope to get started quickly and work in one digital space
- Comply with relevant safety standards and avoid any operation errors
- Leverage the instrument’s automation features so you can focus on more important tasks
- Single magnification for efficient sample measurement
- Analyze 10 µm to 16,000 µm samples with single particle resolution
- Streamline your workflow with user-friendly Kalliope software
- Automate tasks, freeing up valuable time for critical work
- Compatible with Liquid Flow, Dry Jet, Free Fall units
With Litesizer DIA Series, our dynamic image analyzer, you can easily and reliably characterize the size and shape of particles via analysis of their direct images. In just one step, quickly switch among three modules that use dispersion liquid, compressed air or free-fall for excellent dispersion of your sample. Rely on the automation of feeding rate adjustment and rinsing of liquids, and conduct measurements with only minimal training.
That’s particle analysis at the touch of a button - only with our dynamic image analyzer.
Key features
Get particle size and shape in one measurement
Measure particle sizes ranging from 0.5 µm to 16,000 µm with precision, and detect single outlier particles in large samples. Utilize a market-leading liquid dispersion range of up to 2,500 µm. Replace traditional sieve analysis with fast, safe, and dynamic image analysis to gain a deeper understanding of how particle size and optimize your processes.
Optimize measurements with Kalliope software
Start your measurements in just three clicks. Analyze particle size, shape, and images all in one digital space with our dynamic image analyzer. Easily filter particles by specific size and shape using Kalliope’s powerful features. Control all your Anton Paar particle-sizing instruments from the Kalliope particle analysis software platform.
Prioritize operator safety
The Litesizer DIA dynamic image analyzer incorporates multiple safety features to protect the operator. Stay safe with a cover that prevents dangerous sample spread. Prevent overheating with liquid level recognition before sonication. Ensure containment of hazardous samples with automatic suction checks. Comply with relevant safety standards, including EN 61010:2010 and ISO 12100:2011.
Three dispersion units in one dynamic image analyzer
Measure samples using Liquid Flow (liquid dispersion), Dry Jet (compressed air), and Free Fall (gravitational fall) dispersion units. Experience unmatched flexibility in a dynamic image analyzer with the ability to quickly and easily switch between units with the Quick-Click feature, eliminating the hassle of cables and tubes.
Save time with automation
Automatically optimize sample feeding rates, and automate filling, draining, and rinsing tasks to focus on more important work. Enhance data quality and speed up analysis with auto-filtering of particles.
Technical specifications
Feature | Litesizer DIA 700 | Litesizer DIA 500 | Litesizer DIA 100 |
Measurement Principle | Dynamic Image Analysis | ||
Measurement Ranges (Liquid Flow) | 0.5 μm to 2,500 μm | 0.8 μm to 2,500 μm | 10 μm to 2,500 μm |
Measurement Ranges (Dry Jet) | 0.5 μm to 5,000 μm | 0.8 μm to 5,000 μm | 10 μm to 5,000 μm |
Measurement Ranges (Free Fall) | 0.5 μm to 16,000 μm (restrictions apply for particles >8,000 μm) | 0.8 μm to 16,000 μm (restrictions apply for particles >8,000 μm) | 10 μm to 16,000 μm (restrictions apply for particles >8,000 μm) |
Camera | 5 Mpix (2,448 pixels x 2,048 pixels) / 0.5 μm per pixel | 5 Mpix (2,448 pixels x 2,048 pixels) / 0.8 μm per pixel | 5 Mpix (2,448 pixels x 2,048 pixels) / 10 μm per pixel |
Data Collection Rate | 220 fps/camera at 5 Mpix | 144 fps/camera at 5 Mpix | 20 fps/camera at 5 Mpix |
Magnification | 0.3x, 1x and 6x | 0.3x and 4x | 0.3x |
Optical Features | Automatic switch between objectives Automatic merge of size ranges All magnifications are included in the standard configuration | - | |
Data Transfer | 1x 10 Gigabit Ethernet, 1x USB-A 3.0 | ||
Measurement Output | Number-, surface-, and volume-weighted results Size descriptors (ISO 9276-compliant): Minimum and maximum Feret diameters, projected area equivalent diameter, length, geodesic length and thickness (e.g., for fibers), minimum and maximum axes of the Legendre ellipse Shape descriptors (ISO 9276-compliant): aspect ratio, ellipse ratio, irregularity, elongation or eccentricity, circularity, form factor, compactness, extent or bulkiness, solidity, convexity Image parameters: sharpness and contrast | ||
Instrument Data | Dimensions: 400 mm x 790 mm x 290 mm (H x W x D) * Weight: 41 kg (90 lb) * Power supply: 100 V to 240 V ±10 %, 50/60 Hz Compressed air supply: 5 bar - 10 bar (72 psi to 145 psi) Water supply: max. 8 bar (116 psi) | ||
Compatible Dispersion Units | Liquid Flow: Dispersion using a liquid carrier, mixing, and ultrasonication Dry Jet: Dispersion via compressed air Free Fall: Dispersion via gravitational fall | ||
Exchange of the Dispersion Unit | Less than 10 seconds via Quick Click | ||
Automation | Automatic adjustment of the image acquisition rate | ||
Accessories | Calibration tool Pre-configured PC |
Standards
ASTM
European Pharmacopoeia (Ph. Eur.)
ISO
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Behind the Shine: Particle Size and Shape Analysis of Acrylic Paints Application Reports
-
E-Book - Field Guide to Food and Feed Testing Application Reports
-
Full Blast: Monitoring of Size and Shape of Abrasive Materials Application Reports
-
Golden grains: Mastering malt for extraordinary brews Application Reports
-
Know Your Beans: Quality Control of Coffee by Dynamic Image Analysis Application Reports
-
Stir up your measurements: Measuring different particle sizes in one sample Application Reports
-
Your Concrete Answer: Size and Shape Analysis of Cement Application Reports
-
Brochure | Litesizer DIA (US Letter) Brochures
-
Litesizer DIA - IMSI Manuals
Similar products
Consumables, Accessories & Software
Consumables, Accessories & Software
Accessories & Software
Accessories & Software
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
O-RING FOR DRY JET AND FREE FALL MEASUREMENT CELL WINDOW
Litesizer DIA 100 | 500 | 700
O-RING FOR TUBE CONNECTION LIQUID FLOW DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
HOSE FOR COMPRESSED AIR SUPPLY 6x8 MM
Litesizer DIA 100 | 500 | 700
O-RING FOR MEASUREMENT WINDOW LIQUID FLOW DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
HOSE CLAMP 16-27MM 1.4301
Litesizer DIA 100 | 500 | 700
O-RING FOR MEASUREMENT WINDOW LIQUID FLOW DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
COVER FOR LIQUID TANK - TRANSPARENT
Litesizer DIA 100 | 500 | 700
COVER FOR LIQUID TANK - STAINLESS STEEL
Litesizer DIA 100 | 500 | 700
PROTECTIVE GLASS FOR ILLUMINATION UNIT
Litesizer DIA 100 | 500 | 700
PROTECTIVE GLASS FOR CAMERA UNIT
Litesizer DIA 100 | 500 | 700
O-RING FOR MEASUREMENT FRAME LIQUID FLOW DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
SAMPLE FUNNEL SMALL
Litesizer DIA 100 | 500 | 700
SAMPLE FUNNEL LARGE
Litesizer DIA 100 | 500 | 700
DIFFUSER PIPE 3.5 MM FOR DRY JET DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
DIFFUSER PIPE 5 MM
Litesizer DIA 100 | 500 | 700
MEASUREMENT WINDOW DRY JET AND FREE FALL MEASUREMENT CELL
Litesizer DIA 100 | 500 | 700
MEASUREMENT WINDOW FOR LIQUID FLOW
Litesizer DIA 100 | 500 | 700
O-RING FOR DRY JET AND FREE FALL MEASUREMENT CELL WINDOW
Litesizer DIA 100 | 500 | 700
CHUTE COVER FOR FREE FALL
Litesizer DIA 100 | 500 | 700
ANGULAR PIPE CONNECTION VACUUM CLEANER
Litesizer DIA 100 | 500 | 700
DIFFUSER SET 5 MM DRY FOR DRY JET DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
MEASUREMENT CELL 8 MM FOR FREE FALL DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
MEASUREMENT CELL 4 MM FREE FALL DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
CHUTE COVER FOR DRY JET
Litesizer DIA 100 | 500 | 700
DRAIN AND OVERFLOW HOSE HOSE 19X27 PVC
Litesizer DIA 100 | 500 | 700
TEXTILE COVER FOR DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
ANGULAR HOSE CONNECTOR "19 MM (3/4"")"
Litesizer DIA 100 | 500 | 700
SAMPLE AND CLEANING KIT
Litesizer DIA 100 | 500 | 700
PARTICLE SIZE STANDARD PS 413 SIZE RANGE 10 - 100 µm
Litesizer DIA 100 | 500 | 700
PARTICLE SIZE STANDARD PS 234 SIZE RANGE 150 - 650 µm
Litesizer DIA 100 | 500 | 700
DIFFUSER SET 3.5 MM DRY FOR DRY JET DISPERSION UNIT
Litesizer DIA 100 | 500 | 700
Accessory for Litesizer DIA:
Dispersion Unit Liquid Flow
Litesizer DIA 100 | 500 | 700
- Measure samples between 0.5 µm and 2,500 µm
- Automate filing, draining, and rinsing of the dispersion liquid
- Prevent overheating with automatic recognition of liquid
- Use nearly any carrier liquid: Circuit is chemically resistant
Accessory for Litesizer DIA:
Dispersion Unit Dry Jet
Litesizer DIA 100 | 500 | 700
- Measure samples between 0.5 µm and 5,000 µm
- Leverage automation for optimal sample feeding rate
- Prevent toxic or explosive sample spread with the safety cover
- Contain dangerous samples with automatic suction check
Accessory for Litesizer DIA:
Dispersion Unit Free Fall
Litesizer DIA 100 | 500 | 700
- Measure samples between 0.5 µm and 16,000 µm
- Leverage automation for optimal sample feeding rate
- Access the measurement cell for cleaning in one click
- Recover your samples with the built-in drawer
Accessory for Litesizer DIA:
Dispersion Unit
Litesizer DIA 100 | 500 | 700
Software for Particle Analysis:
Kalliope
Litesizer DIA 100 | 500 | 700
- Particle analysis software for Anton Paar particle analyzers
- Start your particle measurements in just three clicks
- One-page workflow user interface
- Live monitoring of measurement results
- Analysis, reporting, and exporting