Combined CO₂ and DO Meter:
CboxQC

  • +4
  • 360°
Model:
  • For measuring dissolved CO2 and O2 in the production environment
  • Sampling directly from process lines, tanks, kegs, and casks
  • Protection class IP67 and rubber housing
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

These combined CO2 and DO meters offer reliable quality control of finished packages, kegs, and casks as well as directly from the process line or tank. They guarantee fast and accurate determination of dissolved CO2 and O2 in beverages during production and bottling. When combined with our filling devices, they let samples be taken directly from the package into the measuring chamber of the combined CO2 and DO meter, without losing dissolved CO2 during the sample transfer.

Key features

Enjoy accurate results in 90 seconds

  • CO2 measurement method guarantees repeatability standard deviations of up to 0.005 vol. or 0.01 g/L (Standard version)
  • The new high-resolution optochemical O2 sensor is accurate and achieves a repeatability standard deviation of ± 2 ppb
  • Not influenced by other dissolved gases such as air or nitrogen
  • CO2 and DO results after only 90 seconds
  • PFD filling device transfers samples from the package into the measuring chamber without any loss of CO2
  • Low sample volume of around 100 mL (Standard version) provides reliable CO2 and DO results, even out of very small packages

Get 11 hours of at-line use with our combined CO₂ and DO meter

  • IP67 leakproof design lets you operate these in harsh, at-line environments
  • Integrated rechargeable battery
  • Compact, lightweight design – ideal for portable use

Use built-in support for self-diagnosis and error detection

  • Intuitive user interface means easy menu navigation
  • Data logger function enables continuous CO2 and DO measurements from the line or tank
  • FillingCheck™ automatically detects filling errors and generates a warning message
  • Guided system check function verifies the tightness of the measuring chamber and the zero point of CO2 and O2 measurements

Manage data in a traceable and convenient way

  • Clear sample identification for 500 traceable measurement results
  • RFID interface lets you make quick changes of measurement settings via RFID tag reading
  • Data is easily printed via Bluetooth® or transferred to a PC via USB

Specifications

 StandardAt-line
Measuring rangeCO20 g/L to 12 g/L (0 vol. to 6 vol.) at 30 °C (86 °F)
0 g/L to 20 g/L (0 vol. to 10 vol.) <15 °C (59 °F)
O20 ppm to 4 ppm
Temperature–3 °C to 40 °C (27 °F to 104 °F), acc. ±0.2 °C
Pressure0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar
Repeatability s.d.CO2±0.01 g/L (0.005 vol.)±0.04 g/L (0.02 vol.)
O22 ppb (in the range <200 ppb)    
ResolutionCO20.001 g/L0.01 g/L
O20.1 ppb (in the range from 0 ppb to 99.9 ppb)
Sample volume>100 mL>150 mL
Measuring unitsCO2g/L, vol., mg/L, kg/cm2, MPa, % w/w
O2ppm, ppb, hPa, mg/L, μg/L, % Air-sat., % O2-sat.
Measuring time90 seconds
Data memory500 measurement data sets
Built-in supportFillingCheck™, CO2 | O2 Data Logger, threshold value functionality, system check
Portable useUp to 11 hours continuous use
Communication interfaces1x RS-232 (CAN-open[1]), 1x USB; optional: 1x RFID, 1x Bluetooth
Protection classIP67
Dimensions (L x W x H)258 mm x 201 mm x 170 mm
(10.2 in x 7.9 in x 6.7 in)
262 mm x 209 mm x 176 mm
(10.3 in x 8.2 in x 6.9 in)
Weight2.6 kg (5.7 lbs)2.7 kg (6 lbs)

[1] CboxQC only

Standards

Open all
Close all

EBC

Chapter 9.28.5 Determination of dissolved Carbon Dioxide in Beer by Volume Expansion - 2008

Mebak

Chapter 2.26.1.5

ASBC

Beer-13D: Dissolved Carbon Dioxide Volume Expansion Method

Standards

Open all
Close all

EBC

Chapter 9.28.5 Determination of dissolved Carbon Dioxide in Beer by Volume Expansion - 2008

Mebak

Chapter 2.26.1.5

ASBC

Beer-13D: Dissolved Carbon Dioxide Volume Expansion Method

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

See more

Similar products