Modular Benchtop Density Meter:
DMA
- Results with four-digit accuracy in 20 s
- One-touch measurement: Measurement at the push of a button
- U-Dry: Effortless hand-swipe drying of measuring cell
- Syringe and measurement status light
- Combinable with 30+ modules for a measurement system
- Automated filling and rinsing via Xsample series
Inspired by over 55 years of expertise in benchtop density measurement, the DMA 4002, DMA 5002, and DMA 6002 modular benchtop density meters combine automated functions with unmatched precision and reliability. As the fastest, most modular benchtop density meters in Anton Paar’s portfolio, they deliver four-digit results in just 20 seconds – powered by U-Pulse technology based on the patented Pulsed Excitation Method for best-in-class accuracy. The instruments offer storage of up to 10,000 measurements and deliver accuracy up to six digits. Daily operations are simplified with features such as U-Dry, one-touch measurement, and a measurement status light, while compliance with a wide range of standards ensures peace of mind. The DMA: always superior.
Customized solutions

Wine Measurement Systems Configuration 2

Beer Measurement Systems Configuration 3

Polymer Measurement Systems Configuration 1

Packaged Beer Measurement Systems Configuration 3

Sake Measurement System

Spirits Measurement System Configuration 2

Wine Measurement Systems Configuration 1

Flavor & Fragrance Measurement System

Packaged Soft Drink Measurement System Configuration 1

Soft Drink Measurement System Configuration 1

Beer Measurement Systems Configuration 2

Packaged Wine Measurement System

Wort Measurement System

Edible Oil Measurement Systems Configuration 1

Jet Fuel Measurement Systems Configuration 2

Lubricant Measurement Systems Configuration 2

Pharma Measurement Systems Configuration 1

Pharma Measurement Systems Configuration 2

Turbidity Measurement System

Alcohol Measurement System

Liqueur Measurement Systems Configuration 1

Liqueur Measurement Systems Configuration 2

Packaged Beer Measurement Systems Configuration 1

Packaged Beer Measurement Systems Configuration 2

Spirits Measurement System Configuration 1

Packaged Soft Drink Measurement System Configuration 3

Beer Measurement Systems Configuration 1

Pharma Measurement Systems Configuration 3
Key features
Outstanding features that simplify workflows
- One-touch measurement: Measurement at the push of a button
- U-Dry: Effortless hand-swipe measurement drying
- FillingCheck: Detection of microbubbles in seconds
- U-View: Zoomable image of the measuring cell
- ThermoBalance: Automatic compensation of temperature effects
- Guided user workflows for simplified operation

Unmatched precision, powered by U-Pulse technology
U-Pulse, based on Anton Paar’s patented Pulsed Excitation Method delivers best-in-class performance – with outstanding precision, repeatability, and reproducibility, whether in high-precision R&D or routine quality control.

Multiparameter measurement systems
The DMA 4002, DMA 5002, and DMA 6002 modular benchtop density meters can be connected to a variety of Anton Paar measuring modules, enabling users to capture all key quality control parameters from a single sample – under identical conditions.

Automation that drives productivity
Fully automated filling, measuring, and cleaning processes take throughput to the next level. Every Anton Paar benchtop density meter is compatible with a wide range of sample changers, enabling tailored setups for maximum speed and reliability. The instruments ensure accurate, operator-independent results while protecting users by minimizing contact with hazardous substances – all while keeping workflows in motion.

Compliance with key standards
The DMA 4002, DMA 5002, and DMA 6002 modular benchtop density meters ensure full compliance with ASTM D4052, D5002, D1250, and ISO 12185 for petroleum testing, as well as all relevant pharmacopeias. They also support data integrity and traceability in line with regulations such as 21 CFR Part 11. Measurements are traceable to the International System of Units (SI) with ISO 17025-accredited calibrations from Anton Paar’s certified laboratory, and top calibration accuracy is maintained using ISO 17034-certified density reference materials.

Specifications
DMA 4002 | DMA 5002 | DMA 6002 | |
---|---|---|---|
Patents | AT 516420 B1 | ||
Measuring range | |||
Density | 0 g/cm³ to 3 g/cm³ | ||
Temperature | 0 °C to 100 °C (32 °F to 212 °F) | ||
Pressure | Up to 10 bar (145 psi) absolute pressure | ||
Accuracy* | |||
Density | 0.00005 g/cm³ | 0.00001 g/cm³ (0 g/cm³ to 1.05 g/cm³, 15 °C to 20 °C) 0.00005 g/cm³ (full range) | 0.000005 g/cm³ |
Temperature | 0.02 °C (0.04 °F) | 0.01 °C (0.02 °F) (15 °C to 20 °C) 0.015 °C (0.03 °F) (full range) | 0.01 °C (0.02 °F) |
Repeatability s.d.** | |||
Density | 0.00001 g/cm³ | 0.000003 g/cm³ | 0.000001 g/cm³ |
Temperature | 0.02 °C (0.04 °F) | 0.005 °C (0.01 °F) | 0.001 °C (0.002 °F) |
Reproducibility s.d.** | |||
Density | 0.00005 g/cm³ | 0.000005 g/cm³ | 0.000005 g/cm³ |
Digital resolution | |||
Density | 0.00001 g/cm³ | 0.000005 g/cm³ | 0.000001 g/cm³ |
Features | |||
Power features | U-Dry, U-View, U-Pulse, FillingCheck, Status Light, Syringe Illumination, ThermoBalance, Full-range viscosity correction | ||
Special functions | Temperature scan, built-in ambient pressure sensor, condition monitoring | ||
Filling options | Automatic sample changers | ||
Modularity | Alcohol, pH, color, turbidity, viscosity, refractive index, optical rotation, CO₂, O₂ | ||
Upgrades and calibrations | Printers, ISO calibration, AP Connect lab execution software | ||
Integrated tables and functions | Density, specific gravity (SG), alcohol tables, sugar/extract tables, various acid/base tables, API functions | ||
Technical data | |||
Ambient temperature | 15 °C to 35 °C (59 °F to 95 °F) | ||
Typical measuring time/sample | 20 s | 30 s | 40 s |
Minimum sample volume | Approx. 1 mL | ||
Wetted materials | Borosilicate glass, PTFE, ETFE | ||
Dimensions (L x W x H) | 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in) | ||
Weight | 22.04 kg (48.6 lbs) | ||
Power supply | AC 100 to 240 V, 50/60 Hz, fluctuation ± 10 %, 190 VA | ||
Display | 10.1" TFT WXGA (1280 x 800 px); PCAP touchscreen | ||
Controls | Touchscreen, optional keyboard, mouse, and barcode reader | ||
Communication interfaces | 4 x USB, Ethernet, CAN, RS232 | ||
Internal storage | 10,000 measuring values including camera images |
* According to ISO 5725
** Under ideal conditions and for low viscosities
Standards
ISO
ASTM
JIS
OIML
OIV
AOAC
ASBC
European Union
HM Revenue & Customs
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
DIN
EBC
IP
GB
HG
JJF
QB
SH
ABNT
RANP
Chinese Pharmacopoeia (ChP)
Japanese Pharmacopoeia (JP)
Standards
ISO
ASTM
JIS
OIML
OIV
AOAC
ASBC
European Union
HM Revenue & Customs
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
EBC
IP
GB
HG
JJF
QB
SH
ABNT
RANP
TTB
DIN
Chinese Pharmacopoeia (ChP)
Standards
ISO
ASTM
JIS
OIML
OIV
AOAC
ASBC
European Union
HM Revenue & Customs
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
EBC
IP
GB
HG
JJF
QB
SH
ABNT
RANP
TTB
DIN
Chinese Pharmacopoeia (ChP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
E-Book - Analytical Methods for the Evaluation of Lubricants Application Reports
Similar products

Compact Digital Density Meter:
DMA

ASTM D4052 Density Meter:
DMA

Multiparameter Measurement System:
Alcohol Measurement System

Multiparameter Measurement System:
Beer Measurement Systems

Multiparameter Measurement System:
Chemical Measurement System

Multiparameter Measurement System:
Edible Oil Measurement Systems

Multiparameter Measurement System:
Flavor & Fragrance Measurement System

Multiparameter Measurement System:
Jet Fuel Measurement Systems

Multiparameter Measurement System:
Liqueur Measurement Systems

Multiparameter Measurement System:
Lubricant Measurement Systems

Multiparameter Measurement System:
Packaged Beer Measurement Systems

Multiparameter Measurement System:
Packaged Soft Drink Measurement System

Multiparameter Measurement System:
Packaged Wine Measurement System

Multiparameter Measurement System:
Pharma Measurement Systems

Multiparameter Measurement System:
Polymer Measurement Systems

Multiparameter Measurement System:
Sake Measurement System

Multiparameter Measurement System:
Soft Drink Measurement System

Multiparameter Measurement System:
Spirits Measurement System

Multiparameter Measurement System:
Sugar Measurement Systems

Multiparameter Measurement System:
Turbidity Measurement System

Multiparameter Measurement System:
Wine Measurement Systems

Multiparameter Measurement System:
Wort Measurement System

Heated Sample Changer:
Xsample 631

Sample Changer:
Xsample 370

Heated Sample Changer:
Xsample 610

Sample Changer:
Xsample 530

Sample Changer:
Xsample 520

Sample Changer:
Xsample 340

Sample Changer:
Xsample 330

Sample Changer:
Xsample 320

Portable Density Meter:
DMA 35
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.


Lab Execution System:
AP Connect Pharma one-time license
DMA 4002 | 5002 | 6002
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Pharma subscription license
DMA 4002 | 5002 | 6002
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Standard one-time license
DMA 4002 | 5002 | 6002
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Standard subscription license
DMA 4002 | 5002 | 6002
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips

Lab Execution System:
AP Connect Start
DMA 4002 | 5002 | 6002
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule

ISO 17034-Certified Reference Material:
Density Standards
DMA 4002 | 5002 | 6002
- Market-leading uncertainty of 0.015 kg/m³ (ISO 17034)
- Application-specific density standards, available via webshop
- Online certificate with lifetime reference values guarantee
- Conformity with ISO requirements ISO 17025 and even ISO 17034
- Safety glass ampoule for zero contamination

HOSE 2000x3x2 FEP 1x 1/4"-28 UNF "EE"
DMA 4002 | 5002 | 6002

SYRINGE 5 mL LUER (WITHOUT SEAL)
DMA 4002 | 5002 | 6002

CABLE TIE HEAT-RESISTANT 100 pcs
DMA 4002 | 5002 | 6002

ACCESSORY KIT DMA HR01 SERIES/DMA 5000 M
DMA 4002 | 5002 | 6002

Protective cover DMA HR01 series
DMA 4002 | 5002 | 6002
made from PETG

Interface caps DMA HR01 series
DMA 4002 | 5002 | 6002

HOSE 3x5 VITON
DMA 4002 | 5002 | 6002

BOTTLE FOR RINSING LIQUID
DMA 4002 | 5002

AP DENSITY STANDARD DODECANE 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4002 | 5002 | 6002
- Density standard with low density (750 kg/m³)
- Organic liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD SODIUM BROMIDE 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4002 | 5002 | 6002
- Density standard with high density (1250 kg/m3)
- Aqueous liquid
- Measuring uncertainty: 0.03 kg/m³
- Specified temperature range: 15 °C – 25 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD GLUCOSE / WATER 10% 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4002 | 5002 | 6002
- Density standard with medium density (1040 kg/m3)
- Aqueous liquid
- Measuring uncertainty: 0.02 kg/m³
- Specified temperature range: 15 °C – 25 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD WATER 1x10 mL WITH ISO 17034 CERTIFICATE
DMA 4002 | 5002 | 6002
- Density standard with medium density (998 kg/m3)
- Aqueous liquid
- Suitable for density adjustments
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 35 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

AP DENSITY STANDARD OIL 30 cSt @ 40 °C 1x10 mL, WITH ISO 17034 CERTIFICATE
DMA 4002 | 5002 | 6002
- Density standard with low density (830 kg/m3)
- Organic liquid
- Viscous liquid
- Measuring uncertainty: 0.015 kg/m³
- Specified temperature range: 15 °C – 50 °C
- Durability: 18 months
- Volume: 10 mL
- ISO 17034-certified reference material
- Complies with ISO 17025 and ISO 17034 requirements

GENDER CHANGER DB9F/DB9F
DMA 4002 | 5002 | 6002

"HOSE 300x3x2 PTFE ""AA"""
DMA 4002 | 5002 | 6002

SYRINGE HOLDER 5 ml FOR 5 ml PLASTIC SYRINGE
DMA 4002 | 5002 | 6002

HOSE 3x5 SILICONE
DMA 4002 | 5002 | 6002

HOSE 2x4 SILICONE
DMA 4002 | 5002 | 6002

HOSE 2x4 VITON
DMA 4002 | 5002 | 6002

PRINTER CONNECTION CABLE
DMA 4002 | 5002 | 6002

ADAPTER LUER 1/4" UNF
DMA 4002 | 5002 | 6002

ADAPTER UNF 1/4"-LUER MALE
DMA 4002 | 5002 | 6002

DRYING CARTRIDGE
DMA 4002 | 5002 | 6002

SYRINGES 2 ml LUER (1000 PCS)
DMA 4002 | 5002 | 6002

KEYBOARD USA USB
DMA 4002 | 5002 | 6002

KEYBOARD GERMAN USB
DMA 4002 | 5002 | 6002

INJECTION ADAPTER UNF 1/4"
DMA 4002 | 5002 | 6002
For density measuring cell

INJECTION ADAPTER LUER
DMA 4002 | 5002 | 6002
For density measuring cell

INJECTION ADAPTER FITTING WITH METAL TUBE
DMA 4002 | 5002 | 6002
For density measuring cell

DENSITY STANDARD TRIMETHYLPENTANE
DMA 4002 | 5002 | 6002

SYRINGES 5 ml LUER (100 pcs.)
DMA 4002 | 5002 | 6002

PROTECTING COVER FOR KEYBOARD
DMA 4002 | 5002 | 6002
In combination with keyboard (80809 or 80807)

MALE LUER PLUG
DMA 4002 | 5002 | 6002

ADAPTER LUER CONE
DMA 4002 | 5002 | 6002

SYRINGE 2 ml LUER (1 PCS)
DMA 4002 | 5002 | 6002

PRINTER PAPER 57x30 STANDARD
DMA 4002 | 6002

DENSITY STANDARD SODIUM BROMIDE
DMA 4002 | 5002 | 6002

HOSE 4X6 SILICONE
DMA 4002 | 5002 | 6002

SYRINGES 2 ml LUER (10 PCS)
DMA 4002 | 5002 | 6002

PRINTER PAPER FOR EPSON TM-U220
DMA 4002 | 5002 | 6002

RIBBON CARTRIDGE FOR EPSON PRINTER TM-U220
DMA 4002 | 5002 | 6002

PRINTER EPSON TM-U220
DMA 4002 | 5002 | 6002

DENSITY STANDARD LUBE OIL LARGO 8cSt@40°C
DMA 4002 | 5002 | 6002

DENSITY STANDARD ETHANOL IN WATER 9%ABV
DMA 4002 | 5002 | 6002

DENSITY STANDARD DEXTROSE IN WATER 10%W/W
DMA 4002 | 5002 | 6002

COLOR ADJUSTMENT SET 3x ULTRA-PURE WATER 2x color standards (50 ml).
DMA 4002 | 5002 | 6002

HEATING ATTACHMENT
DMA 4002 | 5002 | 6002

HOSE CLAMP DMIN 5.8 DMAX 6.5
DMA 4002 | 5002 | 6002

SYRINGES 5 mL LUER-LOCK (100 PCS)
DMA 4002 | 5002 | 6002

SYRINGE 10 mL LUER-LOCK
DMA 4002 | 5002 | 6002
One-way syringe (volume: 10 ml) with Luer-Lock fitting

INJECTION ADAPTER LUER-LOCK
DMA 4002 | 5002 | 6002
for density measuring cell

PROTECTION CAP, BLACK (SQUARE USB INTERFACE)
DMA 5002 | 6002

Filling Device for Aerosols:
Aerosol Adapter
DMA 4002 | 5002 | 6002
- Direct sample filling from aerosol cans
- Compatible with most cans via suitable adapters
- Easily attachable to benchtop density meters
- Pressure gauge and shield for safe operation