TTB, USA
(Alcohol and Tobacco Tax & Trade Bureau, former BATF) certifies the use of Anton Paar density meters in proofing alcohol for tax purposes. Valid for DMA 5000.
HM Customs and Excise, Great Britain
approves the use of Anton Paar density meters for the revenue accounting of spirits. Valid for DMA 5000.
AOAC, international
(Association of Analytical Communities) AOAC Official Method 982.10, Alcohol by volume in distilled liquors, Densitometric method for Anton Paar DMA 55 or equivalent. Valid for DMA 4100, DMA 4500, DMA 5000.
Poland
Polish certificate (Polski Komitet Nomalizacyjny) allowing the use of Anton Paar digital density meters for the determination of alcohol content in distilled products.Valid for DMA 5000.
O.I.V, international
(International Office of Vine and Wine) Automatic Methods for Analysis of Wine and Musts: Alcohol content in volume percent, measurement with digital density meter, required accuracy ±1x10E-5 g/cm3. Valid for DMA 5000.
O.I.V, international
Automatic Methods for Analysis of Wine and Musts: Density with electronic density measurement, required accuracy for density measurement ±1x10E-4 g/cm3 or better. Valid for DMA 4500, DMA 4100.
Spirits drinks: COMMISSION REGULATION (EC) No 2870/2000
Community reference methods for the analysis of spirits drinks: Electronic densimetry is an analytical reference method (method B in Appendix II) for measurement of density of distillate. The used densimeters must be capable of expressing density in g/ml to 5 decimal places with a temperature stability ±0.02 °C or better. Valid for DMA 4500 and DMA 5000.
Wines: COMMISSION REGULATION (EC) No 355/2005
Amending Regulation (EEC) No 2676/90: Community methods for the analysis of wines: Electronic densimetry has been validated in accordance with internationally recognised criteria and has been estimated as a simpler and more accurate means of checking the alcoholic strength by volume of wines. A repeatability of 0.067 ( % vol.) for samples with an alcoholic strength between 4 and 18 %vol is reported. Valid for DMA 4100, DMA 4500, DMA 5000
Wines: COMMISSION REGULATION (EC) No 128/2004
Amending Regulation (EEC) No 2676/90: Community methods for the analysis of wines: The results of determining the alcoholic strength (in %vol) of a wide range of wines show the comparability of measurements carried out with the hydrostatic balance and the electronic density-meter using a frequency oscillator and demonstrate that the values of the validation parameters are similar for both methods. A repeatability of 0.061 ( % vol.) for electronic densimetry is reported. Valid for DMA 4100, DMA 4500, DMA 5000
Wines: COMMISSION REGULATION (EEC) No 2676/90
Community methods for the analysis of wines: for measuring the density or specific gravity at 20 °C the automated method based on the principle of the frequency oscillator is, in respect of its accuracy, repeatability and reproducibility, considered as equivalent to hydrometry or densimetry using a hydrostatic balance; Repeatability for density measurements for dry and semi-sweet wines: r = 0.00010, and for sweet wines: r = 0.00018. Valid for DMA 4100, DMA 4500, DMA 5000.
ASBC, USA
(American Society of Brewing Chemists) Digital densimetry is an approved method for determining specific gravity in beer since 1978. Valid for DMA 4100, DMA 4500, DMA 5000.
MEBAK, Europe
(Mitteleuropäische Brautechnische Analysenkommission) The Anton Paar Beer Analyzer and Beer Alcolyzer/DMA 4500/SP-1m system are accepted methods of measuring alcohol, extract and original extract in beer in the methods book of the Central European Brewing Convention MEBAK, vol. II, 2002.
EBC, Europe
The Analysis Committee of the European Brewing Convention (EBC) decided to include the NIR method in Analytica-EBC and to recommend this method for determination of alcohol in low alcohol beer samples (>0.37 %V/V). 15 of the total 17 participants in a round robin test using NIR equipment used Alcolyzer (Plus) Beer from Anton Paar. See the EBC press release.
ASTM, international
(American Society for Testing and Materials) The density meters DMA 4100, DMA 4500, DMA 5000, DMA HP and DMA HPM fulfill the requirements of the norms ASTM D4052-96 (2002)e1, ASTM D5002-99 (www.astm.org, ASTM Book of Standards, Vol. 05.02, 2004, Petroleum Products and Lubricants (II)) for density measurements in the petroleum industry.
D 5931 - 96 (2002): Digital densimetry is a standard test method for determining the density and relative density of engine coolant concentrates and aqueous engine coolants. Suitable instruments: DMA 4100, DMA 4500, DMA 5000.
DIN, Germany
(Deutsches Institut für Normung) The density meters DMA 4100, DMA 4500, DMA 5000, DMA HP and DMA HPM fulfill the requirements of the norms DIN 51757 (April 1994), DIN ISO 12185 (1997) for density measurements in the petroleum industry.
ISO, international
ISO 15212-1:1999-06: Oscillation-type density meters - Part 1: Laboratory instruments. The Anton Paar DMA density meters fulfil the requirements of the norm. Maximum permissible error: 0.001 g/cm3. Valid for DMA 35N models, DMA 38, DMA 4100, DMA 4500, DMA 5000.
EN ISO2811-3: Paints and varnishes - Determination of density. Part 3: Oscillation method. Densimetry based on the principle of the frequency oscillator is a standard method. Required repeatability 0.0001 g/ml. Suitable instruments: DMA 4100, DMA 4500.
Pharmacopoeia, Europe
All digital density meters are acknowledged by the European Pharmacopoeia Forum (www.pheur.org) for density measurement in pharmaceutical analysis (European Pharmacopoeia 5.0 (2005), pp. 27-28; Pharmeuropa, Vol. 15, No. 1, January 2003, pp. 174-175), accuracy for relative density ±1x10E-3 g/cm3 and better, repeatability ±1x10E-4 g/cm3 and better. Valid for DMA 35N, DMA 38, DMA 4100, DMA 4500, DMA 5000
Pharmacopoeia, USA
With effect from January 1st, 2006, the oscillating U-tube method is accepted as density/specific gravity measuring method by the US-Pharmacopoeia (www.usp.org). According to "USP 29 - <841> Specific Gravity Method II" digital density meters can now also be used officially for drug analysis (USP29-NF24, p.2766; Pharmacopeial Forum, Vol. No. 31 (2), p. 515). Valid for DMA 35N, DMA 38, DMA 4100, DMA 4500, DMA 5000
ATEX Certificate by TÜV, Austria
(Technischer Überwachungs-Verein) Design and construction of the DMA 35N Ex and DMA 35N Ex Petrol are certified for use in potentially explosive atmospheres. (EC-Type-Examination Certificate according to Directive 94/9/EC).
GOST, Russia
All Anton Paar digital density meters and Alcolyzer/Alcolyzer Plus instruments are officially acknowledged by the GOST certificate (Pattern Approval Certificate) for Russia. Valid for all density meters and alcohol meters.