Stabinger Viscometer SVM 3000
Enlarge image
  Upcoming exhibitions
   
    JAIMA Show >
   (03 Sep 2008)
 
    Biodiesel-Expo 2008 >
   (15 Oct 2008)
 
   Show more exhibitions for the productline

  
    

Stabinger Viscometer SVM 3000
Features & Benefits

 

Rotational viscometer for oil viscosity

  Viscosity measurement has never been so easy:
The SVM 3000 works according to a new, patented (EP 0 926 481 A2) measuring principle. Just fill the measuring cell with 3 ml of sample and obtain both dynamic and kinematic viscosity and density values. The viscosity index calculation is also integrated.
 

The new standard for viscometry: ASTM D7042

  The SVM 3000 fulfills all requirements of the ASTM D7042: Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity). See "Declaration of Conformity" in the Download area.

The precision obtained by the SVM 3000 in the interlaboratory study conducted by ASTM subcommittee D02.07A was shown to be equivalent to the precision achieved in measurements made according to ASTM D445. No significant bias could be found between the methods. For details review the "Precision and Bias" document in the Download area. The D7042 standard can be obtained from the ASTM Web shop.
 

A unique technical concept for high accuracy

  The extremely high sensitivity of the eddy current torque measuring system and the integrated thermoelectric temperature control provides unrivalled precision. The torque resolution is an unmatched 50 pico-Nm. This is comparable to the torque resulting from a dust particle on a 1 cm lever arm and allows for a minimized measuring cell.
 

Advantages at a glance

 
  • No water bath, no liquid-in-glass thermometers.
  • No change of capillaries - one measuring cell covers the whole viscosity range.
  • Equivalent precision and no bias to ASTM D445.
  • Minimal lab space and low power consumption.
  • The fastest precision viscometer ever.
 
    
   