Turbidity Measuring Module: HazeQC ME

A solution for the measurement of turbidity in liquids, the HazeQC ME turbidity measuring module, is now provided by Anton Paar as part of a new modular measuring system. The approved ratio method with measurement at three angles (transmission 0°, scattered light at 25° and 90°) is used to prevent the influence of particle size on the turbidity value. The measurement is carried out at a wavelength of 650 nm ±30 nm (MEBAK- and EBC-compliant) in a cell with adjustable constant temperature. This turbidity measuring module expands Anton Paar's product portfolio and adds a further important parameter for analyzing liquid samples - providing the same high quality expected of Anton Paar products.

Accurate and traceable turbidity measurement

  • Three-angle turbidity measurement (transmission 0°, scattered light at 25° and 90°) at 650 nm according to MEBAK and EBC
  • Approved ratio method eliminates the influence of particle size on the turbidity value
  • Highly accurate Peltier-thermostatted cell (0.01 °C stability)

Combinations for up to 7 parameters possible

  • Up to 7 parameters in one measuring cycle if used in combination with PBA-B (density, alcohol, beer color, pH, CO2, O2, turbidity)
  • Combination with Alcolyzer Plus Beer or with the Beer Analyzing System (Alcolyzer Plus Beer, density meter, sample changer)
  • All measurements directly out of the bottle or can, no degassing required if using a PFD Filling Device
Measuring range
Turbidity 0 to 100 EBC (0 to 400 NTU)
Temperature 0 to 40 °C (temperatures below 15 °C require an external cooling)
Repeatability s.d.
Turbidity 0.02 EBC (0.08 NTU)
Temperature 0.01 °C
Additional information
Measurement principle Three-angle stray light and absorbance measurement (0°, 25° and 90°), ratio method for the reduction of interferences
Wavelength 650 nm
Minimum sample volume approx. 3 mL
Measuring time per sample 3 to 4 minutes (incl. filling)
Interfaces 2 x RS-232
Wetted parts EPDM, FEP, glass, PEEK, PTFE, PU, stainless steel, Tygon
Dimensions
(L x W x H)
380 x 160 x 190 mm (15 x 6.3 x 7.5 inches)
Weight 5.3 kg (11,7 lbs)
External thermostat (optional) Flow rate: 0.4 to 0.7 L/min
Maximum pressure: 0.5 bar (7.3 psi)
Temperature of the cooling medium: 15 to 25 °C (59 to 77 °F)