Modular Compact Rheometer:
MCR 72/92
- Robusni
- Opremljen motorom s kugličnim ležajem
- Za mjerenja u rotaciji (i oscilaciji za specijalne primjene)
- Idealan za mjerenje ponašanja protoka Vašeg uzorka
The two new members of the renowned Modular Compact Rheometer (MCR) series – MCR 72 and MCR 92 – are the two wisest choices for quick and easy rheological measurements. These real rheometer “pearls” from Anton Paar are streamlined for your daily lab routine, easy to use in a plug-and-play fashion, and available at an accommodating price. There is a range of accessories available for both models. The step-by-step software and special features like TruRay (integrated light), QuickConnect (fast and easy mounting of the measuring system), Toolmaster™ (automatic tool recognition and configuration), etc. guarantee excellent ease of use. For academic use, both instruments are available as an EDU Edition, including a special EDU package for teaching staff as well as EDU Student Packages.
Glavne značajke

Two models designed for your application
Two new rheometers are available: MCR 72 is equipped with a ball-bearing motor (very robust in use, no compressed air required) and MCR 92 with an air-bearing motor (highly accurate for sensitive samples). The two rheometers enable measurements in both rotational and oscillatory mode. The choice of rheometer depends on your application. To investigate the deformation and flow behavior of your sample (also at different temperatures), consider MCR 72. For observing sample structure, MCR 92 is recommended. Both instruments have a motor that lifts up the measuring head automatically to set an exact measuring gap. This gap is 100 % reproducible. MCR 72 and MCR 92 can both be equipped with temperature devices to cover a range from -50 °C to +400 °C.

Your key to accuracy – the motor technology
25 years of experience in one motor – you only get this with rheometers from Anton Paar. The air-bearing-supported synchronous EC motor deploys a frictionless synchronous movement of the rotor inside that enables the most sensitive and therefore most precise movements. Whether investigating solids or low-viscosity liquids your results are accurate across a wide viscosity range.

Step-by-step software
The intuitive RheoCompass™ software helps you to find the test template you need, customize tests and analysis definitions, export your data and generate reports. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos and pictures for extra support. Different accounts can be created for each operator working in the lab.

Unique features for easy handling and reproducible results
The highlight of these two rheometer models is the patented TruRay lighting of the measuring surface, which can be gradually regulated for a clear view of your sample. When changing between measuring systems, QuickConnect allows one-handed connection of the measuring systems and ensures fast, convenient system changes without the use of a screwing mechanism. Then, Toolmaster™ takes over by automatically recognizing the mounted tool and temperature units. Finally, the SafeGap feature ensures that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time.

Experienced experts close to you
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. One thousand installed instruments around the globe, an extensive application database, a website full of practical information (World of Rheology), the book “Applied Rheology – With Joe Flow on Rheology Road”, eLearning courses and numerous published works by our rheology experts confirm that Anton Paar is the first choice for answering any rheological question you may have.
Tehničke specifikacije
Specifications | Units | MCR 72 | MCR 92 |
Bearing | - | Ball | Air |
EC motor (brushless DC) with high resolution optical encoder | - | ✔ | ✔ |
Rotation Mode | - | ✔ | ✔ |
Oscillation Mode | - | ✔(1 | ✔ |
Direct Strain Controller | - | ✔ | ✔ |
Direct Stress Controller | - | ✔ | ✔ |
Maximum torque | mNm | 125 | 125 |
Minimum torque, rotation | µNm | 200 | 1 |
Minimum torque, oscillation | µNm | 200 | 1 |
Torque resolution | nNm | 100 | 100 |
Angular deflection, set value | µrad | 1 to ∞ | 1 to ∞ |
Angular deflection, resolution | nrad | 614 | 614 |
Step rate, time constant | ms | 100 | 100 |
Step strain, time constant | ms | 100 | 100 |
Minimum angular velocity (2 | rad/s | 10-4 | 10-4 |
Maximum angular velocity | rad/s | 157 | 157 |
Minimum angular frequency (3 | rad/s | 10-3 | 10-4 |
Maximum angular frequency | rad/s | 628 | 628 |
Minimum speed (CSS/CSR) | rpm | 10-3 | 10-3 |
Maximum speed | rpm | 1500 | 1500 |
Maximum temperature range | °C | -50 to +400 | -50 to +400 |
SafeGap, Normal force Limiter during Gapsetting | - | ✔ | ✔ |
TruRay, Dimmable illumination of sample area | - | ✔ | ✔ |
Connections | USB, Ethernet, RS232, Analog interfaces, Pt100 port | ||
Dimensions | mm | 380 x 660 x 530 | 380 x 660 x 530 |
Weight | kg | 33 | 33 |
QuickConnect for measuring systems, screwless | - | ✔ | ✔ |
ToolmasterTM, measuring system | - | ✔ | ✔ |
ToolmasterTM, measuring cell | - | ✔ | ✔ |
CoolPeltierTM, Peltier-controlled Plate System with built in cooling option that requires no additional accessories for counter-cooling | °C | 25 below ambient temperature but not lower than -5 up to +200 (4 | |
Actively Peltier-controlled hood that requires no additional accessories for counter-cooling | °C | -5 to 200 (4 | |
CoolPeltierTM, Peltier-controlled Cylinder System with built in cooling option that requires no additional accessories for counter-cooling | °C | 15 below ambient temperature but not lower than +5 up to +150 (4 | |
Virtually gradient-free (horizontal, vertical) temperature control | - | ✔ | ✔ |
Rheometer Software: | |||
Test Designer | - | ✔ | ✔ |
Report Designer | - | ✔ | ✔ |
User Management | - | ✔ | ✔ |
Electronic trim lock for the measuring system | - | ✔ | ✔ |
Automatic gap control/setting, AGC/AGS | - | ✔ | ✔ |
Also available as EDU Edition (for educational institutions only):
- MCR 72 or MCR 92 plus accessories with a special academic discount
- Free EDU Toolbox including lab equipment and educational material
1) Depending on sample properties
2) Depending on measuring point duration and sampling time, practically any value is achieved
3) Set frequencies below 10-4 rad/s are of no practical relevance due to the measuring point duration > 1 day
4) System temperature, sample temperature may vary. For measurements at very high or low temperatures a calibration in the sample gap is recommended.
Standardi
ASTM
DIN
DIN EN
EN
ICA
IOCCC
ISO
Pharmacopoeia Europe (Ph. Eur.)
U.S. Pharmacopoeia (USP)
Certificirana usluga servisa Anton Paar
- Više od 350 tehničkih stručnjaka s certifikatom proizvođača širom svijeta
- Kvalificirana podrška na vašem lokalnom jeziku
- Zaštita za vaše ulaganje tijekom njegovog životnog ciklusa
- Trogodišnje jamstvo
Dokumenti
-
MCR 72 and MCR 92 Brošure
-
MCR 72 and MCR 92 (US Letter) Brošure
-
CE Declaration of Conformity MCR 72 and MCR 92 Certifikati
-
Beverage | Soft Drinks | Complete Your Soft Drink Analysis Izvješća o zahtjevu
-
Calculation of the Critical Shear Rate in a Cylinder Measuring System Izvješća o zahtjevu
Slični proizvodi
Dodatni pribor
Dodatni pribor
Dodatni pribor
Dodatni pribor
Da biste saznali možete li putem interneta kupovati sa svoje lokacije, provjerite dostupnost na mreži u nastavku.
Ako ne pronađete predmet koji vam je potreban, kontaktirajte svog prodajnog predstavnika tvrtke Anton Paar.

MEASURING CONE CP40-2 D:
40 mm; ANGLE 2°
MCR 72/92 MCR 72

Optical accessory for MCR:
Rheometer-Infrared Spectrometer Setup
MCR 72/92 MCR 72 | MCR 92
- Accessory for structure analysis and rheo optics
- Combines rheology with infrared spectroscopy
- Investigates the chemical composition of a material

INSET I-PP50/CU/CX D:
50 mm; COPPER ALLOY, COATED
MCR 72/92 MCR 92

Accessory for MCR and RheolabQC:
Flexible Cup Holder
MCR 72/92 MCR 72 | MCR 92
- Accessory for “Extended Material Characterization"
- Holds, for example: paint cans, yogurt cups, other containers
- Can be combined with stirrers, concentric cylinder geometries, and a Pt100 temperature sensor

MEASURING CONE CP50-0.5 D:
50 mm; ANGLE 0.5°
MCR 72/92 MCR 72

MEASURING PLATE PP20 D:
20 mm
MCR 72/92 MCR 92


MEASURING CONE CP40-1 D:
40 mm; ANGLE 1°
MCR 72/92 MCR 72

MEASURING PLATE PP25/P2 D:
25 mm, PROFILED: 1X0.5
MCR 72/92 MCR 92

MEAS. CYLINDER B-CC27 D:
26.66 mm
MCR 72/92 MCR 72 | MCR 92

SPATULA
MCR 72/92 MCR 72 | MCR 92

Dodatni pribor za MCR:
Geometrije za reometar
MCR 72/92 MCR 72 | MCR 92

STANDARD MEASURING SYSTEM CC39/T200/XL/AL
MCR 72/92 MCR 72 | MCR 92
- measuring cylinder B-CC39/Q1
- measuring cup C-CC39/T200/AL