  • Compact, patented design optimized for benchtop XRD applications
  • Temperature control range: -10 °C to +150 °C (BTS 150) and up to 500 °C (BTS 500)
  • Fast, accurate temperature control with sensor near the sample
  • Straightforward sample handling, alignment, and remote control via USB
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The BTS 150 and BTS 500 Benchtop Heating Stages are the first commercial non-ambient stages for XRD studies on benchtop diffractometers. Their unique design is patented and offers all the features a benchtop diffraction application requires - compactness, reliability and ease of use!

Measurements can be performed between –10 °C and 150 °C with the BTS 150 and from ambient to 500 °C with the BTS 500. Both instruments are extremely compact in design to fit into the restricted space of typical benchtop diffractometers.
 

Key features

Fast and accurate temperature control

  • Temperature range from –10 °C to 150 °C (BTS 150)
    or from ambient to 500 °C (BTS 500)
  • Accurate temperature measurement by a thermo sensor close to the sample
  • Fast heating and cooling

Optimized for ease of operation

  • Easy handling and exchange of samples
  • Easy alignment possibilities
  • High position stability and minimum thermal expansion of sample holder
  • Adjustable beam knife to minimize background at low 2θ
  • Remote control via USB connection possible

Optimized design for benchtop instruments

  • Compact and lightweighted design with integrated temperature controller
  • No external cooling required (only air cooling) for BTS 500 or optional water cooling for BTS 150 at lowest temperatures

Specifications

Operating temperatureambient to 500 °C (BTS 500)
-10 to 150 °C (BTS 150) 
Temperature measurementPt100
AtmosphereVacuum (10-1 mbar), air, inert gas, nitrogen
Angle of incidence (2Θ)0 to 164°
Max. operating pressure1 bar above atmospheric pressure
Sample holder materialNickel or ceramics (Al2O3)
Sample size16 x 14 mm

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty