Cold Filter Plugging Point Tester:
Callisto 100
- Determines the low-temperature operability of diesel, biodiesel, diesel blends, and gas oils
- Saves time with high sample throughput, intuitive operation, and easy cleaning
- Preprogrammed standard methods
upon request
The fully automated, compact, stand-alone CFPP tester Callisto 100 determines the low-temperature operability in diesel fuel, biodiesel, diesel blends and gas oils.
Callisto 100 comes with a newly developed state-of-the-art Peltier element concept which allows the connection of a methanol-free cooling system. It ensures outstanding homogeneity of the cooling jacket, which is the most critical and decisive parameter for a correct CFPP value determination.
Key features
Benefits at a Glance
- Error-free detection
- Easy and intuitive operation
- High sample throughput
- Convenient cleaning routines
Convenient Operation
- Thanks to contact-free infrared detection technology the complete filtration unit is easily accessible
- Excellent detection, even when the pipette is frosted.
- Pre-programmed standard test methods to select from the menu allow for immediate start of the test
- Large color display indicates the sample and jacket temperature in real time
- Graphical information about the aspiration and back flow times to observe the temperature behavior of the sample
- Statistical evaluation of test results with min/max/average according to the test method
- Self-explanatory calibration procedures for the temperature and vacuum
- Automated pre-cleaning routine can be initiated
Customized User Flexibility
- Also applicable for manual cloud and pour point measurements
Technical specifications
Measuring range | -60 °C to +45 °C |
---|---|
Cooling profiles | Programmable stepped or linear (from 6 °C/h to 100 °C/h) |
Calibration | Automatic calibration routine for sample and jacket temperature and vacuum measurement Temperature probe correction table |
External cooling units | User-supplied or available from Anton Paar as an accessory Cooling power: 280 W at -20 °C |
Data memory | 1000 results 90 user-defined programs |
Data export | Connectivity via USB stick, e.g. to export test results as XLS or PDF files |
Interfaces | 4x USB, 1x RS232, 1x LAN, 1x VGA |
Power supply | 100 V to 240 V, 50 Hz/60 Hz, 290 VA |
Dimensions | 340 mm x 580 mm x 310 mm (W x D x H) |
Weight | 14 kg |
Resolution | 0.1 °C |
Standards
ABNT
ASTM
EN
IP
JIS
RANP
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Callisto 100: A Small Cooling Unit for a Single Instrument Application Reports
-
Three Callisto 100 Share One Cooling Unit Application Reports
Consumables & Accessories
Consumables & Accessories
To find out if you can purchase online from your location, check the online availability below.
If you do not find the item you require, please contact your Anton Paar sales representative.

Test jar D= 34 mm x 120 mm, d= 31 mm

Sealing gaskets for pipette, pack of 10

Sealing gaskets for filter sieve, 10 Pcs

Temperature probe Pt100 for Callisto 100

Test assembly EN 116, complete

Clamping ring Pt100

Insulating Hose Set, 2x2m

Touchscreen stylus Bellagio Mini silver

O-Ring 50,52 x 1,78 NBR 50

Silicone tubing ID=4 AD=6 Wt=1 L=400 mm

Spacer for Pt100

O-ring 32x1.5 FPM 80 VITON + packed

Filter sieve 45 µm mesh

Filter assembly complete without pipette

Centering guide EN 16329

Cleaning station Callisto 100

Measuring pipette, 20 ml

Beaker 250 ml, tall form with spout

CFPP sample jar