此為必填欄位。
Invalid
零件編號
驗證錯誤!

溫度控制:
PTD 80

  • Three-quarter front view of the ViscoQC 300 rotational viscometer with the PTD 80 Peltier temperature device against a light blue background
  • Wide lab shot of two technicians working with ViscoQC 100 and ViscoQC 300 rotational viscometers with the PTD 80 Peltier temperature device, with sample bottles and jars on the bench under a fume hood
  • Angled close-up of the ViscoQC 300 touchscreen as a gloved hand taps the interface, showing a gear oil test and PTD 175 temperature at −40.0 °C
  • Three-quarter front view of the ViscoQC 300 rotational viscometer with the PTD 80 Peltier temperature device, with accessories laid out beside the base on a light blue background
  • Close-up angled view of the PTD 80 Peltier temperature device, showing the temperature chamber opening and vented housing mounted on the ViscoQC viscometer base
  • Three-quarter front view of the ViscoQC 300 rotational viscometer with the PTD 80 Peltier temperature device against a light blue background
  • Wide lab shot of two technicians working with ViscoQC 100 and ViscoQC 300 rotational viscometers with the PTD 80 Peltier temperature device, with sample bottles and jars on the bench under a fume hood
  • Angled close-up of the ViscoQC 300 touchscreen as a gloved hand taps the interface, showing a gear oil test and PTD 175 temperature at −40.0 °C
  • +2
  • 15 °C 至 80 °C 的快速主動加熱與冷卻
  • 固態 Peltier:無需液體介質,有助於降低洩漏風險並減少維護需求
  • 可透過 ViscoQC 全面控制,簡化操作流程
  • 緊湊設計:節省實驗台空間並簡化安裝
  • T-Ready™ 功能可提示樣品已達熱平衡

PTD 80 採用簡潔、堅固且節省空間的設計,有助於擴展溫控黏度測量的應用範圍,可立即投入使用。 其採用固態 Peltier 技術,無需冷卻液,即可在 15 °C 至 80 °C 範圍內快速升降溫。 PTD 80 的所有操作均可直接透過 ViscoQC 完成,支援所有圓筒系統,包括 DIN、SC4 小體積樣品系統及 UL,適用樣品體積為 2 mL 至 20 mL。 T-Ready™ 功能可提示樣品已達溫度平衡,有助於進行可靠且重複性良好的測量。

主要功能

無需冷卻液,減少維護需求

不同於傳統的循環式恆溫槽,PTD 80 採用固態 Peltier 技術,無需使用冷卻液。 因此可減少冷卻液與軟管相關的洩漏風險與定期維護需求,同時降低量測位置受污染的風險。 主動加熱與冷卻的典型速率為 3 °C/min,可快速且有效率地調整溫度。 達到設定溫度後,系統可維持 ±0.1 °C 的溫度穩定度,有助於確保黏度量測的準確性與再現性。

  • 無需恆溫槽與恆溫液體,減少相關維護需求
  • 升溫與降溫反應快速,可節省時間
  • 溫度穩定度高,量測結果具再現性
Wide lab shot of two technicians working with ViscoQC 100 and ViscoQC 300 rotational viscometers with the PTD 80 Peltier temperature device, with sample bottles and jars on the bench under a fume hood

穩定溫控,結果更可靠

T-Ready™ 功能可顯示樣品何時達到設定溫度,有助於每次量測在一致的溫度條件下進行。 透過 ViscoQC 進行整體控制,可將溫度設定直接整合至量測方法中,簡化操作流程並減少手動介入。 可直接在 ViscoQC 中套用偏移值進行溫度校正,有助於維持結果的準確性與可靠性。

  • T-Ready™ 有助於在精確設定的溫度下進行量測
  • 透過 ViscoQC 控制溫度與測試流程
  • 可在 ViscoQC 中透過偏移值進行溫度校正
Angled close-up of the ViscoQC 300 touchscreen as a gloved hand taps the interface, showing a gear oil test and PTD 175 temperature at −40.0 °C

樣品量更少,量測更快

PTD 80 可在固定溫度下執行例行品質控制,也可在預先設定的溫度點之間自動進行溫度掃描。 相較於傳統的轉子與燒杯配置,PTD 80 可搭配圓筒式量測系統使用,所需樣品量僅 2 mL 至 20 mL。 熱平衡所需時間可由數小時縮短為數分鐘,有助於加快量測並提高通量。

  • DIN:符合 ISO 3219,剪切速率定義明確
  • SC4-xx:少量樣品量測系統
  • UL26 與 DG26:可量測低至 1 mPa·s 的黏度
Three-quarter front view of the ViscoQC 300 rotational viscometer with the PTD 80 Peltier temperature device, with accessories laid out beside the base on a light blue background

佔用空間更小,環境負荷更低

PTD 80 可直接整合在 ViscoQC 下方,幾乎不額外佔用空間,也無需外接式溫度控制器或恆溫槽。這種緊湊設計可節省寶貴的實驗台空間,簡化系統安裝,並提升整體操作便利性。除了節省實體空間外,PTD 80 也能藉由高效運作,幫助降低環境負荷。

  • 幾乎不額外佔用空間
  • 無需外接式溫度控制器或恆溫槽
  • 相較於恆溫設備,耗電量可降低 90 %
  • 由 ViscoQC 直接供電,無需額外電源線
Close-up angled view of the PTD 80 Peltier temperature device, showing the temperature chamber opening and vented housing mounted on the ViscoQC viscometer base

規格

溫度範圍 [°C]+15 至 +80
溫度穩定性 [°C]±0.1
支援的黏度計ViscoQC 100
ViscoQC 300
支援的量測系統同心圓筒(DIN)、雙間隙、超低黏度轉接器、小量樣品轉接器
冷卻液
熱管理主動加熱與冷卻
外接電源供應器

安東帕認證服務

安東帕在服務和支援方面的品質:
  • 全球超過 350 位製造商認證的技術專家
  • 以當地語言提供的合格支援
  • 在整個儀器生命週期中保護您的投資
  • 三年保固