This is a required field.
Invalid
Part number
Error in validation!

Domed Cooling Stage for Four-Circle Goniometers:
DCS 500

  • DCS 500 Domed Cooling Stage is the smallest attachment for in-situ X-ray diffraction studies at low and high temperatures
  • DCS 500 Domed Cooling Stage is the smallest attachment for in-situ X-ray diffraction studies at low and high temperatures
  • For in-situ X-ray diffraction studies at low and high temperatures on four-circle goniometers and XYZ stages
  • Temperature range from -180 °C to +500 °C
  • For the investigation of layered structures, phase transformations, and stress in crystalline material
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The DCS 500 Domed Cooling Stage is the smallest attachment for in-situ X-ray diffraction studies at low and high temperatures on four-circle goniometers and XYZ stages. With a temperature range from -180 °C to +500 °C and a theta angle from almost 0° to 90° 2Θ for all Φangles, DCS 500 is the ideal sample stage for in-situ studies of layered structures and for investigating phase transformations and stress in crystalline material.

Key features

Exact sample temperature and variable sample environment

  • Liquid nitrogen cryostat for fast cooling down to -180 °C
  • Resistance heater for fast heating up to +500 °C
  • Accurate PT100 RTD close to the sample for precise temperature measurement and control
  • Highly X-ray transparent graphite dome for measurements under vacuum, in air and other gases

Compact design

  • Smart and variable sample fixing allows reflectivity measurements
  • Low weight (850 g)
  • Thin, vacuum-insulated liquid nitrogen hoses with high flexibility down to -180 °C

Specifications

Operating temperature
in air, inert gas

25 °C to 500 °C
In vacuum (< 5x10-1 mbar)-180 °C to 500 °C
Temperature measurementPT100
AtmospheresVacuum (10-1 mbar), air, inert gas
Max. operating pressure0.3 bar above atmospheric pressure
Sample holder materialNickel-plated copper alloy
Sample diametermax. 25 mm
Dome materialGraphite
TransmissionCu Kα 72 %
Measuring geometryReflection

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more