This is a required field.
Invalid
Part number
Error in validation!

Cold Filter Plugging Point Tester:
Callisto 100

  • Determines the low-temperature operability of diesel, biodiesel, diesel blends, and gas oils
  • Saves time with high sample throughput, intuitive operation, and easy cleaning
  • Preprogrammed standard methods
Pick your country.
Americas
Brazil
PT
Canada
EN | FR
Colombia
ES
Mexico
ES
Peru
ES
United States
EN
Europe
Austria
DE
Belgium
EN | FR
Croatia
EN
Czech Republic
CS
Denmark
EN
Finland
EN
France
FR
Germany
DE
Hungary
HU
Ireland
EN
Italy
IT
Liechtenstein
DE | FR | IT
Luxembourg
EN | FR
Netherlands
EN
Poland
PL
Slovakia
CS
Slovenia
EN
Spain
ES
Sweden
EN
Switzerland
DE | FR | IT
United Kingdom
EN
Africa & Middle East
South Africa
EN
Turkey
TR
United Arab Emirates
EN
Asia-Pacific
Australia
EN
India
EN
Japan
JA
Malaysia
EN
New Zealand
EN
Philippines
EN
Singapore
EN
South Korea
EN | KO
Taiwan
ZH
Thailand
EN
Vietnam
EN | VI
If you can't find your country in the list get a quote

The fully automated, compact, stand-alone CFPP tester Callisto 100 determines the low-temperature operability in diesel fuel, biodiesel, diesel blends and gas oils.

Callisto 100 comes with a newly developed state-of-the-art Peltier element concept which allows the connection of a methanol-free cooling system. It ensures outstanding homogeneity of the cooling jacket, which is the most critical and decisive parameter for a correct CFPP value determination.

Key features

Benefits at a Glance

  • Error-free detection
  • Easy and intuitive operation
  • High sample throughput
  • Convenient cleaning routines

Convenient Operation

  • Thanks to contact-free infrared detection technology the complete filtration unit is easily accessible
  • Excellent detection, even when the pipette is frosted.
  • Pre-programmed standard test methods to select from the menu allow for immediate start of the test
  • Large color display indicates the sample and jacket temperature in real time
  • Graphical information about the aspiration and back flow times to observe the temperature behavior of the sample
  • Statistical evaluation of test results with min/max/average according to the test method
  • Self-explanatory calibration procedures for the temperature and vacuum
  • Automated pre-cleaning routine can be initiated

Customized User Flexibility

  • Also applicable for manual cloud and pour point measurements

Specifications

Measuring range-60 °C to +45 °C
Cooling profilesProgrammable stepped or linear
(from 6 °C/h to 100 °C/h)
CalibrationAutomatic calibration routine for sample and jacket temperature and vacuum measurement
Temperature probe correction table
External cooling unitsUser-supplied or
available from Anton Paar as an accessory
Cooling power: 280 W at -20 °C
Data memory1000 results
90 user-defined programs
Data exportConnectivity via USB stick, e.g. to export test results as XLS or PDF files
Interfaces4x USB, 1x RS232, 1x LAN, 1x VGA
Power supply100 V to 240 V, 50 Hz/60 Hz, 290 VA
Dimensions340 mm x 580 mm x 310 mm (W x D x H)
Weight14 kg
Resolution0.1 °C

Standards

Open all
Close all

ASTM

D6371

EN

116
16329

IP

309

JIS

K 2288

ABNT

NBR 14747

RANP

30
40
45
48
50
71
764

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

No results found!

See more