Particle size analyzer:
PSA
- Multi laser system
- Measurement range liquid: 0.04 µm to 2500 µm
- Measurement range dry: 0.1 µm to 2500 µm
upon request
With the laser diffraction technology of the PSA series you can determine the particle size and particle size distribution of both – liquid dispersions and dry powders from the nanometer up to the millimeter range. The knowledge of the material’s particle size and size distribution is essential for product development and quality control as these two parameters have an impact on the processability as well as the properties of the final product. The instruments of this series incorporate more than fifty years of experience. The world’s first laser diffraction particle size analyzer – the first-ever PSA – was invented in 1967.
Key features

Compact 2-in-1 design to measure both wet and dry samples
PSA instruments are the only particle size analyzers that can be configured with fully integrated liquid and dry dispersion modules within one instrument. Sample dispersion as well as the measurement take place inside the instrument. This unique design eliminates the need for the operator to handle several accessories, exchange the hardware, or make manual adjustments. The software enables the switching between liquid and dry dispersion mode with a single mouse click, which saves time and prevents operation errors.

Multi-laser technology for a broad measurement range
The multi-laser technology provides an extensive range of measurable particle sizes. The single-laser PSA 990 covers a measurement range of 0.2 μm to 500 μm. For an even broader range, PSA 1090 and PSA 1190 have a unique optical design for diffraction analysis, which includes multiple lasers. While PSA 1090 has been designed with two lasers to resolve particles as small as 40 nanometers, PSA 1190 contains an additional third laser to cover the full measurement range of up to 2.5 millimeters. The use of solid state lasers ensures that instruments of the PSA series are ready to measure right after being switched on as nearly no warm-up time is required.

Accurate size distribution of dry powders
The size distribution of dry powders is often difficult to measure because the particles tend to agglomerate, which falsifies the results. Dry Jet Dispersion (DJD) technology is Anton Paar’s patented technique (FR2933314) for efficiently dispersing and precisely analyzing powder particles. The innovative design features an air pressure regulator that quickly and easily adjusts the air flow in accordance with the sample properties. The shear forces created by the air flow separate agglomerated particles ensuring that primary particles are detected.

Accuracy, repeatability, and stability for a lifetime
Anton Paar’s particle size analyzers are fully ISO 13320 compliant to meet the requirements for traceable, accurate, and repeatable results. The unique design of the lasers and the optical bench set the market standard for a measurement reproducibility that is better than 1 % variation. Furthermore, the optical bench design has all optical components permanently mounted on a cast-iron base plate. This ensures realignment-free operation, making PSA the ideal instrument not only for R&D environments, but also for harsh environments. Thus, accuracy, reproducibility, and stability are guaranteed for the instruments’ entire life time.
Technical specifications
PSA 990 | PSA 1090 | PSA 1190 | |
---|---|---|---|
Measurement principle | Laser diffraction | ||
Measuring range (dry) | 0.3 μm to 500 μm | 0.1 μm to 500 μm | 0.1 μm to 2500 μm |
Measuring range (wet) | 0.2 μm to 500 μm | 0.04 μm to 500 μm | 0.04 μm to 2500 μm |
Dry dispersion | Venturi | Venturi | Venturi/Freefall |
Liquid dispersion | 2 peristaltic pumps/ultrasonic transducer/stirrer | ||
Repeatability | <1 % | ||
Accuracy | <3 % | ||
Measuring time | <1 min | ||
Number of lasers | 1 | 2 | 3 |
Laser safety classification | FDA Title 21 CFR - Part 1040 & EN 60825-1:2014 | ||
Laser class, closed cover | Class 1 of EN 60825-1:2014 | ||
Laser class, open cover | Class 3R of EN 60825-1:2014 | ||
Digital data security | FDA Title 21 CFR - Part 11 | ||
Electromagnetic compatibility | EN 61326-1:2013 | ||
Low voltage | EN 61010-1:2010 & EN 61010-2-081:2015 | ||
Dimensions (L x D x H) | 890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in | ||
Weight | ~55 kg |
Standards
ASTM
ISO
U.S. Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Accuracy, repeatability and reproducibility of PSA Application Reports
-
Black and green: catalyst and membranes for fuel cells Application Reports
-
Brick on Brick: Particle Size Distributions of Building Materials Application Reports
-
Catalyst Characterization - From Fresh to Spent Application Reports
-
Characterization of metal powders along the reuse in Additive Manufacturing Application Reports
-
Citius Altius Fortius – Drinks for Athletes Application Reports
-
Dig This – Particle Size Analysis of Soil Application Reports
-
Fits Like a Glove: Particle Characterization for Latex Glove Production Application Reports
-
Food Characterization Application Reports
-
From Pottery to Membranes: Characterization of Ceramic Powders and Surfaces Application Reports
-
Granulation and Drying: the Choice of Excipients Matters Application Reports
-
Heavy Duty Made Easy: Particle Size Analysis for the Cement Industry Application Reports
-
Here Comes the Sun - Using Laser Diffraction to Characterize Cosmetics Application Reports
-
Material Characterization for Battery Cell Manufacturing Application Reports
-
Measure the Pleasure: Particle Size Analysis of Chocolate Powder Application Reports
-
Metal Powder Characterization Application Reports
-
Mie and Fraunhofer: use the correct approximation model Application Reports
-
Milk Powder Characterization - Chapter 2: Packaging, Transport, and Storage Application Reports
-
Old MacDonald had a Plan: Laser Diffraction for Animal Feed Analysis Application Reports
-
On Easy Street – Characterization of Bitumen Emulsions Application Reports
-
Particle Size Analysis for the Pharmaceutical Industry Application Reports
-
Particles for Breakfast: Using Laser Diffraction for Particle Sizing in Food Application Reports
-
Powder Coatings: Important Parameters for Quality Control and Development Application Reports
-
Software Features of Anton Paar Instruments for the Pharma Industry Application Reports
-
Taste and Health Can Coexist: Particle Size Analysis of Mayonnaise Application Reports
-
With Flying Colors: Pigment Size Analysis using Dry Jet Dispersion Technology Application Reports
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
To find out if you can purchase online from your location, check the online availability below.
If you do not find the item you require, please contact your Anton Paar sales representative.

Drypoint Air Dryer with Air Filter Unit
PSA 1190 | 1090 | 990

Cell 3mm Liquid PSA 3432641
PSA 1190

Cell 1mm Liquid PSA 3424185
PSA 1090 | 990

T - HOSE CONNECTOR 6mm
PSA 1190 | 1090 | 990

Particle Size Standard PS315 Kit
PSA 1190 | 1090 | 990

Particle Size Standard PS314 Kit
PSA 1190 | 1090 | 990

Tube Silicone Masterflex PSA 6795050
PSA 1190 | 1090 | 990

Viton Masterflex ID 6.4mm
PSA 1190 | 1090 | 990

Viton Upgrade Kit for SVU
PSA 1190 | 1090 | 990

Hose 10X16 PVC
PSA 1190 | 1090 | 990

Hose 16x22 PVC
PSA 1190 | 1090 | 990

Cleaning Strips Measurement Cell 190x30
PSA 1190 | 1090 | 990

Dust Bags Numatic HZ200 Hepa-Flo 10pcs
PSA 1190 | 1090 | 990

PSA Small Volume Unit
PSA 1190 | 1090 | 990

Autosampler
PSA 1190 | 1090 | 990
- Automates the PSA series: for both wet and dry dispersions
- Automatic pick-up and pouring of up to 30 samples in one cycle
- Define measurements in the PSA software, start a run, and dedicate your time to other tasks