High-Pressure Volumetric Gas Sorption Analyzer:
iSorb

  • High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
  • Two laboratory technicians operating computers displaying software interfaces for the Anton Paar iSorb HP high-pressure gas sorption analyzer. The screens show schematic diagrams of gas flow paths and system settings, highlighting precise control and monitoring capabilities for high-pressure gas sorption experiments. The lab environment includes advanced instrumentation in the background.
  • High-pressure sample cells and accessories for the Anton Paar iSorb HP gas sorption analyzer, including various stainless steel sample cells for powders, granules, films, and monoliths. A thermal insulation sleeve and a compact pressure booster with a 4:1 compression ratio are also shown, supporting cryogenic to elevated temperature experiments.
  • Close-up of the Anton Paar iSorb HP2 high-pressure gas sorption analyzer, showing the thermostatically controlled manifold with tubing and connections inside a transparent blue-front chamber. The control panel on the side highlights the safety features, including automated valve closure and pressure monitoring for high-pressure gas experiments.
  • Computer monitor displaying the software interface for the Anton Paar iSorb HP high-pressure gas sorption analyzer. The screen shows a detailed schematic of the gas flow system, including valves, pumps, and sample cells, used for measuring adsorption isotherms, sample kinetics, and heat of adsorption at various temperatures.
  •  Two laboratory technicians in lab coats reviewing data on a monitor displaying graphical logs of pressure and temperature readings from the Anton Paar iSorb HP gas sorption analyzer. The system interface includes animated diagnostics and valve operation logs for maintenance planning and analysis playback.
  • High-pressure volumetric gas sorption analyzer iSorb HP2 by Anton Paar, featuring a sleek silver design with a transparent blue-front chamber, internal tubing, and precision components visible inside. The device includes control panels and ports for gas adsorption measurements, designed for high-pressure gas storage and separation analysis.
  • Two laboratory technicians operating computers displaying software interfaces for the Anton Paar iSorb HP high-pressure gas sorption analyzer. The screens show schematic diagrams of gas flow paths and system settings, highlighting precise control and monitoring capabilities for high-pressure gas sorption experiments. The lab environment includes advanced instrumentation in the background.
  • High-pressure sample cells and accessories for the Anton Paar iSorb HP gas sorption analyzer, including various stainless steel sample cells for powders, granules, films, and monoliths. A thermal insulation sleeve and a compact pressure booster with a 4:1 compression ratio are also shown, supporting cryogenic to elevated temperature experiments.
  • +3
Model:
  • Two-station gas sorption analyzer
  • High-pressure measurements up to 200 bar pressure

The iSorb HP gas sorption analyzers are perfect for evaluating materials in gas storage, gas separation, or emission control applications. With high-precision transducers, precise manifold temperature control, and a built-in library of advanced equations of state, the iSorb HP series gives you access to high-quality gas adsorption and kinetic data to a maximum of either 100 bar or 200 bar absolute. Optional temperature control accessories allow measurements over a temperature range of 75 K to 773 K.

Key features

Robust manifold design ensures results unaffected by temperature and ambient conditions

High-pressure experiments require well-controlled temperature for accurate and precise measurements. Therefore, the manifold of the iSorb HP is thermostatically heated above room temperature for better stability and isolation from environmental changes. Microprocessor-based digital pressure transducers provide temperature-compensated pressure readings. The software monitors the stability of the manifold temperature and gas pressure before dosing into the sample cell; readings taken at stable temperatures provide for the most precise and accurate measurements. Metal VCR seals and pneumatic valves ensure leak-tight operation.

Two laboratory technicians operating computers displaying software interfaces for the Anton Paar iSorb HP high-pressure gas sorption analyzer. The screens show schematic diagrams of gas flow paths and system settings, highlighting precise control and monitoring capabilities for high-pressure gas sorption experiments. The lab environment includes advanced instrumentation in the background.

Highly flexible experimental conditions

iSorb HP features a variety of high pressure sample cells that accommodate a wide range of sample types: powders, granules, films, and monoliths. Sample temperature is controlled by several accessories from cryogenic (75 K) to elevated temperatures (773 K). The low-volume micro cell enables you to determine the performance of your materials even when sample amount is limited. The reduced void space and excellent temperature control help eliminate the need to perform blank subtraction runs. The compact pressure booster produces a 4:1 compression result maintaining 200 bar with as little as 55 bar left in the gas cylinder to save you money and resources.

High-pressure sample cells and accessories for the Anton Paar iSorb HP gas sorption analyzer, including various stainless steel sample cells for powders, granules, films, and monoliths. A thermal insulation sleeve and a compact pressure booster with a 4:1 compression ratio are also shown, supporting cryogenic to elevated temperature experiments.

Peace of mind with built-in safety

Working at higher pressures with hazardous gases means safety is of utmost concern. With the iSorb HP, sample cell pressure is constantly monitored, even in the event of a power outage; during a power outage the instrument will automatically close all valves. Its “Safe State” routine returns the manifold and sample cell to ambient pressure with helium enabling easy sample removal. The intelligent software has an automatic leak detection algorithm that can differentiate between adsorption and a leak. If a leak is detected, the instrument will stop the analysis and return to a safe state, and can trigger an external alarm. An automated supply-line cleaning routine prevents mixing of two incompatible gases.

Close-up of the Anton Paar iSorb HP2 high-pressure gas sorption analyzer, showing the thermostatically controlled manifold with tubing and connections inside a transparent blue-front chamber. The control panel on the side highlights the safety features, including automated valve closure and pressure monitoring for high-pressure gas experiments.

Insights into sample kinetics, heat adsorption at different temperatures, and more

Surface excess isotherms are easily obtained with the iSorb HP with two built-in methods: classical target pressure mode or faster pressure dosing. You can also explore the sample kinetics of each data point collected and calculate the heat of adsorption from multiple isotherms collected at different analysis temperatures. Absolute adsorbed amount isotherm and storage capacity calculations will aid R&D in finding the next novel material for gas storage capabilities. 

Computer monitor displaying the software interface for the Anton Paar iSorb HP high-pressure gas sorption analyzer. The screen shows a detailed schematic of the gas flow system, including valves, pumps, and sample cells, used for measuring adsorption isotherms, sample kinetics, and heat of adsorption at various temperatures.

Permanent control of instrument status and health

The valve management system records each cycle of the valves to help you plan your maintenance schedule. The exportable graphical log file records all pressure and temperature readings and valve operations along with animated graphics for rapid diagnostics and complete analysis playback.

 Two laboratory technicians in lab coats reviewing data on a monitor displaying graphical logs of pressure and temperature readings from the Anton Paar iSorb HP gas sorption analyzer. The system interface includes animated diagnostics and valve operation logs for maintenance planning and analysis playback.

Specifications

Performance/physicaliSorb HP1iSorb HP2
Analysis stations12
Gas inputs2 (optional 4)
Maximum pressure data100 bar or 200 bar absolute
Minimum pressure data0.0005 bar
Low Pressure (LP) transducers2 (1 bar)3 (1 bar)
High Pressure (HP) transducers23
Total transducer count46
Transducer accuracy<±0.05 % f.s
Vacuum pumpinternal
Turbo pump optionyes
Degas typeautomatic
Degas portsin-situ
Max. degas temp500 °C
Thermostatted bath optionyes
Cryo optionyes
Booster optionyes
Thermostatted manifoldyes
Gas inputs/vents locationSide, for easy access
Dimensions (W x H x D)85 cm x 100 cm x 50.5 cm (33.5 in x 39.25 in x 19.5 in)
Weight150 kg (330 lbs)150 kg (330 lbs)

 

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
  • 3-year warranty
Learn more

Documents

Categories
Industry
Application
Your choice: Reset all filters

Consumables

Consumables

Not all items are purchasable online in specific countries.

To find out if you can purchase online from your location, check the online availability below.

VCR GASKET, 1/4 INCH, AG, 0.5 µm FILTER

Compatible with:
iSorb HP1 100 | HP1 200 | HP2 100 | HP2 200
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 196508
Product details
316 SS VCR Face Seal Fitting. 1/4 inch Silver-plated snubber gasket non-retainer style 0.5 micron (per unit)

iSorb RECIRCULATING DEWAR SEAL, SILICONE

Compatible with:
iSorb HP1 100 | HP1 200 | HP2 100 | HP2 200
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 197764

VACUUM GREASE .25 OUNCE

Compatible with:
iSorb HP1 100 | HP1 200 | HP2 100 | HP2 200
Online price only | excl.incl. 0VAT
Delivery time: %1$s – %2$s working days %1$s – %2$s weeks %1$s – %2$s months
Part number: 193946