Cold Filter Plugging Point Tester:
Callisto 100
- Determines the low-temperature operability of diesel, biodiesel, diesel blends, and gas oils
- Saves time with high sample throughput, intuitive operation, and easy cleaning
- Preprogrammed standard methods
The fully automated, compact, stand-alone CFPP tester Callisto 100 determines the low-temperature operability in diesel fuel, biodiesel, diesel blends and gas oils.
Callisto 100 comes with a newly developed state-of-the-art Peltier element concept which allows the connection of a methanol-free cooling system. It ensures outstanding homogeneity of the cooling jacket, which is the most critical and decisive parameter for a correct CFPP value determination.
Key features
Benefits at a Glance
- Error-free detection
- Easy and intuitive operation
- High sample throughput
- Convenient cleaning routines
Convenient Operation
- Thanks to contact-free infrared detection technology the complete filtration unit is easily accessible
- Excellent detection, even when the pipette is frosted.
- Pre-programmed standard test methods to select from the menu allow for immediate start of the test
- Large color display indicates the sample and jacket temperature in real time
- Graphical information about the aspiration and back flow times to observe the temperature behavior of the sample
- Statistical evaluation of test results with min/max/average according to the test method
- Self-explanatory calibration procedures for the temperature and vacuum
- Automated pre-cleaning routine can be initiated
Customized User Flexibility
- Also applicable for manual cloud and pour point measurements
Specifications
Measuring range | -60 °C to +45 °C |
---|---|
Cooling profiles | Programmable stepped or linear (from 6 °C/h to 100 °C/h) |
Calibration | Automatic calibration routine for sample and jacket temperature and vacuum measurement Temperature probe correction table |
External cooling units | User-supplied or available from Anton Paar as an accessory Cooling power: 280 W at -20 °C |
Data memory | 1000 results 90 user-defined programs |
Data export | Connectivity via USB stick, e.g. to export test results as XLS or PDF files |
Interfaces | 4x USB, 1x RS232, 1x LAN, 1x VGA |
Power supply | 100 V to 240 V, 50 Hz/60 Hz, 290 VA |
Dimensions | 340 mm x 580 mm x 310 mm (W x D x H) |
Weight | 14 kg |
Resolution | 0.1 °C |
Standards
ASTM
EN
IP
JIS
ABNT
RANP
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Application Report: Testing of Renewable Fuels Application Reports
-
Callisto 100: A Small Cooling Unit for a Single Instrument Application Reports
-
Efficiency Meets Sustainability – Biodiesel Measurements Made Easy Application Reports
-
Testing of Immersion Cooling Fluids Application Reports
-
Datasheet: Callisto 100 Brochures
-
Reference Guide: Callisto 100 Manuals
Complementary products
If you do not find the item you require, please contact your Anton Paar sales representative.

SPRING CLAMP
The spring clamp stabilizes the pipette during the measurement and enhances the sample recognition by the light barrier.

TEST JAR CAPP
Test jar CAPP

O-RING, 5.28 x 1.78 mm, NBR, PACK OF 10
O-ring for the sealing gasket for the pipette. Pack of 10.

O-RING, 12,42 x 1,78 mm, NBR, Pacote com 10 unidades
O-RING para a junta de vedação da peneira do filtro. Embalagem com 10 unidades.

TEMPERATURE SENSOR, SAMPLE PT100, METAL (Callisto 100)
Temperature probe Pt100, made of metal

TEST ASSEMBLY EN 116
Test assembly EN 116. The set consists of:
- 1 Filter assembly complete without pipette (P/N 106725)
- 1 Centering guide EN 116 (P/N 106726)
- 1 Measuring pipette, 20 mL (P/N 141692)
- 1 Measuring lid with light rod (P/N 147154)
- 1 CFPP sample jar (P/N 172530)

CLAMPING COLLAR, PLASTIC (POM), d = 6.1 mm, D = 12 mm, M4
Clamping ring to adjust the Pt100 temperature sensor, made of plastic

KIT FOR MANUAL CLOUD AND POUR POINT MEASUREMENT
Kit of standardized CAPP accessories for manual measurements of cloud and pour point

HOSE SET, INSULATED, 2 x 2 m
Hose set, insulated, 2 × 2 m

TOUCHSCREEN STYLUS
Touchscreen stylus Bellagio Mini

O-RING, 50.52 x 1.78 mm, NBR
O-ring for measuring and calibration lid, NBR

HOSE, SILICONE, d = 4 mm, L = 400 mm. Hose, silicone.

SPACER, D = 27 mm, H = 1.5 mm
Spacer for Pt100 temperature sensor

O-RING, 32 x 1.5 mm, FKM
O-ring for sealing narrow mouth bottle

FILTER SIEVE 45 µm MESH
Filter sieve 45 µm mesh

FILTER ASSEMBLY (WITHOUT PIPETTE)
Filter assembly complete without pipette. The set consists of:
- 1 Filter sieve 45 µm mesh (P/N 106724)
- 2 O-rings for the sealing gasket for the pipette (P/N 106272)
- 1 O-ring for the sealing gasket for the filter sieve (P/N 106273)

CENTERING GUIDE EN 16329
Centering guide for the linear cooling method EN 16329

CLEANING STATION Callisto 100
Cleaning station for the filter assembly and pipette

MEASURING PIPETTE, 20 mL
Measuring pipette, 20 mL

BEAKER 250 mL, TALL FORM WITHOUT SPOUT
Beaker 250 mL, tall form without spout

TEST JAR CFPP STANDARD
CFPP sample jar made of glass